Acumed LLC

FDA adverse event reports naming Acumed LLC as the device manufacturer, with recall history from the live FDA recall database. Reporter-supplied name as filed: ACUMED LLC.

Total reports
3,188
Deaths
0
Injuries
1,908
Malfunctions
1,265

Reports per year

12
13
14
15
16
17
18
19
20
21
22
23
24
25
26

Source: FDA adverse event reports by year received, 2012–2026. Reporting paused twice in 2026 during FDA reporting-system changes and has since resumed.

Top device categories

Recent recalls

  • 2026-06-23Open, ClassifiedDevice Design

    Acumed Hexalob Screw various sizes: REF Numbers: : 3070-27008 2.7mm x 8mm NL Hexalobe Screw; 3070-27009 2.7mm x 9mm NL Hexalobe Screw; 3070-27010 2.7mm x 10mm NL Hexalobe Screw; 3070-27011 2.7mm x 11mm NL Hexalobe Screw; 3070-27012 2.7mm x 12mm NL Hexalobe Screw; 3070-27013 2.7mm x 13mm NL Hexalobe Screw; 3070-27014 2.7mm x 14mm NL Hexalobe Screw; 3070-27015 2.7mm x 15mm NL Hexalobe Screw; 3070-27016 2.7mm x 16mm NL Hexalobe Screw; 3070-27017 2.7mm x 17mm NL Hexalobe Screw; 3070-27018 2.7mm x 18mm NL Hexalobe Screw; 3076-30010 3.0mm x 10mm NL Hexalobe Screw; 3076-30012 3.0mm x 12mm NL Hexalobe Screw; 3076-30014 3.0mm x 14mm NL Hexalobe Screw

    Due to manufacturing error, hexalobe screws used with wrist fixation system may break during use.

  • 2024-02-29Open, ClassifiedNo Marketing Application

    Acu-Loc and Acu-Loc 2 bone plates, screws and accessories for the following REF: 70-0045 Acu-Loc VDU Plate Standard, Left; 70-0045-S Acu-Loc VDU Plate Standard, Left; 70-0046 Acu-Loc VDU Plate Standard, Right; 70-0046-S Acu-Loc VDU Plate Standard, Right; 70-0047 Acu-Loc VDU Plate Long, Left; 70-0047-S Acu-Loc VDU Plate Long, Left; 70-0048 Acu-Loc VDU Plate Long, Right; 70-0048-S Acu-Loc VDU Plate Long, Right; 70-0055 Acu-Loc Dorsal Plate, Standard, left; 70-0055-S Acu-Loc Dorsal Plate, Standard, left; 70-0056 Acu-Loc Dorsal Plate, Standard, Right; 70-0056-S Acu-Loc Dorsal Plate, Standard, Right; 70-0057 Acu-Loc Dorsal Plate, Narrow, Left; 70-0057-S Acu-Loc Dorsal Plate, Narrow, Left; 70-0058 Acu-Loc Dorsal Plate, Narrow, Right; 70-0058-S Acu-Loc Dorsal Plate, Narrow, Right; 70-0331 Divergent Radial Styloid Plate; 70-0331-S Divergent Radial Styloid Plate; 70-0334 Volar Lunate Suture Plate; 70-0334-S Volar Lunate Suture Plate; 70-0335 Dorsal Rim Buttress Plate, Right; 70-0335-S Dorsal Rim Buttress Plate, Right; 70-0336 Dorsal Rim Buttress Plate, Left; 70-0336-S Dorsal Rim Buttress Plate, Left; 70-0337 Dorsal Lunate Plate, Right; 70-0337-S Dorsal Lunate Plate, Right; 70-0338 Dorsal Lunate Plate, Left;

    Distribution without Pre-Market Clearance

  • 2023-12-26Open, ClassifiedUnknown/Undetermined by firm

    RibLoc U Plus 90 Instrument PRIMARY GUIDE ASSY, LOW PROFILE REF RBL2320 The RBL2320, Low Profile Primary Guide is an instrument used with a power system to compress the RibLoc plates onto the bone, determine the length of the screw to install, locate the position of the holes to drill, and provide proper orientation for the installation of the screws.

    Due to potential breakage during use.

  • 2022-12-23Open, ClassifiedNo Marketing Application

    Part Number/Part Description: 30-0033-S 30mm Acutrak Fusion Device 6mm Nose AM-0025-S 25.0mm Acutrak 4/5 Bone Screw AM-0030-S 30.0mm Acutrak 4/5 Bone Screw AM-0035-S 35.0mm Acutrak 4/5 Bone Screw AM-0040-S 40.0mm Acutrak 4/5 Bone Screw AM-0045-S 45.0mm Acutrak 4/5 Bone Screw AM-0050-S 50.0mm Acutrak 4/5 Bone Screw AP-67100-S 100mm Acutrak 6/7 Fixation Screw AP-67105-S 105mm Acutrak 6/7 Fixation Screw AP-67110-S 110mm Acutrak 6/7 Fixation Screw AP-67115-S 115mm Acutrak 6/7 Fixation Screw AP-67120-S 120mm Acutrak 6/7 Fixation Screw AP-6740-S 40mm Acutrak 6/7 Fixation Screw AP-6745-S 45mm Acutrak 6/7 Fixation Screw AP-6750-S 50mm Acutrak 6/7 Fixation Screw AP-6755-S 55mm Acutrak 6/7 Fixation Screw AP-6760-S 60mm Acutrak 6/7 Fixation Screw AP-6765-S 65mm Acutrak 6/7 Fixation Screw AP-6770-S 70mm Acutrak 6/7 Fixation Screw AP-6775-S 75mm Acutrak 6/7 Fixation Screw AP-6780-S 80mm Acutrak 6/7 Fixation Screw AP-6785-S 85mm Acutrak 6/7 Fixation Screw AP-6790-S 90mm Acutrak 6/7 Fixation Screw AP-6795-S 95mm Acutrak 6/7 Fixation Screw ATF-140-S 14.0mm Acutrak Fusion Device ATF-160-S 16.0mm Acutrak Fusion Device ATF-180-S 18.0mm Acutrak Fusion Device ATF-200-S 20.0mm Acutrak Fusion Device ATF-220-S 22.0mm Acutrak Fusion Device ATF-240-S 24.0mm Acutrak Fusion Device ATF-270-S 27.0mm Acutrak Fusion Device ATF-320-S 32.0mm Acutrak Fusion Device ATF-370-S 37.0mm Acutrak Fusion Device ATM-100-S 10.0mm Mini Acutrak Fixation Screw ATM-120-S 12.0mm Mini Acutrak Fixation Screw ATM-140-S 14.0mm Mini Acutrak Fixation Screw ATM-160-S 16.0mm Mini Acutrak Fixation Screw ATM-180-S 18.0mm Mini Acutrak Fixation Screw ATM-200-S 20.0mm Mini Acutrak Fixation Screw ATM-220-S 22.0mm Mini Acutrak Fixation Screw ATM-240-S 24.0mm Mini Acutrak Fixation Screw ATM-260-S 26.0mm Mini Acutrak Fixation Screw

    Distribution without Pre-Market Clearance

  • 2022-12-23Open, ClassifiedNo Marketing Application

    Acutrak 2 Part Number/Part Description: 30-0021 25.0mm Acutrak 2 - 5.5 Screw 30-0021-S 25.0mm Acutrak 2 - 5.5 Screw 30-0023 30.0mm Acutrak 2 - 5.5 Screw 30-0023-S 30.0mm Acutrak 2 - 5.5 Screw 30-0025 35.0mm Acutrak 2 - 5.5 Screw 30-0025-S 35.0mm Acutrak 2 - 5.5 Screw 30-0027 40.0mm Acutrak 2 - 5.5 Screw 30-0027-S 40.0mm Acutrak 2 - 5.5 Screw 30-0029 45.0mm Acutrak 2 - 5.5 Screw 30-0029-S 45.0mm Acutrak 2 - 5.5 Screw 30-0031 50.0mm Acutrak 2 - 5.5 Screw 30-0031-S 50.0mm Acutrak 2 - 5.5 Screw 30-0084 55.0mm Acutrak 2 - 5.5 Screw 30-0084-S 55.0mm Acutrak 2 - 5.5 Screw 30-0085 60.0mm Acutrak 2 - 5.5 Screw 30-0085-S 60.0mm Acutrak 2 - 5.5 Screw 30-0620 20.0mm Acutrak 2 - 4.7 Screw 30-0620-S 20.0mm Acutrak 2 - 4.7 Screw 30-0622 22.0mm Acutrak 2 - 4.7 Screw 30-0622-S 22.0mm Acutrak 2 - 4.7 Screw 30-0624 24.0mm Acutrak 2 - 4.7 Screw 30-0624-S 24.0mm Acutrak 2 - 4.7 Screw 30-0626 26.0mm Acutrak 2 - 4.7 Screw 30-0626-S 26.0mm Acutrak 2 - 4.7 Screw 30-0628 28.0mm Acutrak 2 - 4.7 Screw 30-0628-S 28.0mm Acutrak 2 - 4.7 Screw 30-0630 30.0mm Acutrak 2 - 4.7 Screw 30-0630-S 30.0mm Acutrak 2 - 4.7 Screw 30-0635 35.0mm Acutrak 2 - 4.7 Screw 30-0635-S 35.0mm Acutrak 2 - 4.7 Screw 30-0640 40.0mm Acutrak 2 - 4.7 Screw 30-0640-S 40.0mm Acutrak 2 - 4.7 Screw 30-0645 45.0mm Acutrak 2 - 4.7 Screw 30-0645-S 45.0mm Acutrak 2 - 4.7 Screw 30-0650 50.0mm Acutrak 2 - 4.7 Screw 30-0650-S 50.0mm Acutrak 2 - 4.7 Screw 30-0740 40.0mm Acutrak 2 - 7.5 Screw 30-0740-S 40.0mm Acutrak 2 - 7.5 Screw 30-0745 45.0mm Acutrak 2 - 7.5 Screw 30-0745-S 45.0mm Acutrak 2 - 7.5 Screw 30-0750 50.0mm Acutrak 2 - 7.5 Screw 30-0750-S 50.0mm Acutrak 2 - 7.5 Screw 30-0755 55.0mm Acutrak 2 - 7.5 Screw 30-0755-S 55.0mm Acutrak 2 - 7.5 Screw 30-0760 60.0mm Acutrak 2 - 7.5 Screw 30-0760-S 60.0mm Acutrak 2 - 7.5 Screw 30-0770 70.0mm Acutrak 2 - 7.5 Screw 30-0770-S 70.0mm Acutrak 2 - 7.5 Screw 30-0775 75.0mm Acutrak 2 - 7.5 Screw 30-0775-S 75.0mm Acutrak 2 - 7.5 Screw 30-0780 80.0mm Acutrak 2 - 7.5 Screw 30-0780-S 80.0mm Acutrak 2 - 7.5 Screw 30-0785 85.0mm Acutrak 2 - 7.5 Screw 30-0785-S 85.0mm Acutrak 2 - 7.5 Screw 30-0790 90.0mm Acutrak 2 - 7.5 Screw 30-0790-S 90.0mm Acutrak 2 - 7.5 Screw 30-0795 95.0mm Acutrak 2 - 7.5 Screw 30-0795-S 95.0mm Acutrak 2 - 7.5 Screw 30-0800 100.0mm Acutrak 2 - 7.5 Screw 30-0800-S 100.0mm Acutrak 2 - 7.5 Screw 30-0805 105.0mm Acutrak 2 - 7.5 Screw 30-0805-S 105.0mm Acutrak 2 - 7.5 Screw 30-0810 110.0mm Acutrak 2 - 7.5 Screw 30-0810-S 110.0mm Acutrak 2 - 7.5 Screw 30-0815 115.0mm Acutrak 2 - 7.5 Screw 30-0815-S 115.0mm Acutrak 2 - 7.5 Screw 30-0820 120.0mm Acutrak 2 - 7.5 Screw Micro Acutrak 2 Part Number/Part Description: AT2-C08 through AT2-S34-S 8.0-34.0mm, Micro Acutrak 2 Bone Screw

    Distribution without Pre-Market Clearance

  • 2022-12-23Open, ClassifiedNo Marketing Application

    AcuTwist Acutrak Compression Screws Part Number/Part Description: AI-0010-S 10mm AcuTwist Acutrak Compression Screw AI-0012-S 12mm AcuTwist Acutrak Compression Screw AI-0014-S 14mm AcuTwist Acutrak Compression Screw AI-0016-S 16mm AcuTwist Acutrak Compression Screw AI-0018-S 18mm AcuTwist Acutrak Compression Screw AI-0020 20mm AcuTwist Acutrak Compression Screw AI-0020-S 20mm AcuTwist Acutrak Compression Screw AI-0022-S 22mm AcuTwist Acutrak Compression Screw AI-0024-S 24mm AcuTwist Acutrak Compression Screw AI-0026 26mm AcuTwist Acutrak Compression Screw AI-0026-S 26mm AcuTwist Acutrak Compression Screw AI-0028-S 28mm AcuTwist Acutrak Compression Screw AI-0030 30mm AcuTwist Acutrak Compression Screw AI-0030-S 30mm AcuTwist Acutrak Compression Screw

    Distribution without Pre-Market Clearance

  • 2022-12-23Open, ClassifiedNo Marketing Application

    Dual-Trak Clavicle Screws Part Number/Part Description: 40-0136 3.0mm x 80mm Dual-Trak Clavicle Screw 40-0136-S 3.0mm x 80mm Dual-Trak Clavicle Screw 40-0137 3.0mm x 90mm Dual-Trak Clavicle Screw 40-0137-S 3.0mm x 90mm Dual-Trak Clavicle Screw 40-0138 3.0mm x 100mm Dual-Trak Clavicle Screw 40-0138-S 3.0mm x 100mm Dual-Trak Clavicle Screw 40-0139 3.0mm x 110mm Dual-Trak Clavicle Screw 40-0139-S 3.0mm x 110mm Dual-Trak Clavicle Screw 40-0140 3.0mm x 120mm Dual-Trak Clavicle Screw 40-0140-S 3.0mm x 120mm Dual-Trak Clavicle Screw 40-0143 3.8mm x 80mm Dual-Trak Clavicle Screw 40-0143-S 3.8mm x 80mm Dual-Trak Clavicle Screw 40-0144 3.8mm x 90mm Dual-Trak Clavicle Screw 40-0144-S 3.8mm x 90mm Dual-Trak Clavicle Screw 40-0145 3.8mm x 100mm Dual-Trak Clavicle Screw 40-0145-S 3.8mm x 100mm Dual-Trak Clavicle Screw 40-0146 3.8mm x 110mm Dual-Trak Clavicle Screw 40-0146-S 3.8mm x 110mm Dual-Trak Clavicle Screw 40-0147 3.8mm x 120mm Dual-Trak Clavicle Screw 40-0147-S 3.8mm x 120mm Dual-Trak Clavicle Screw

    Distribution without Pre-Market Clearance

  • 2017-03-16TerminatedProcess control

    .045 X 6 ST Guide Wire, Part number 45-0029-S, Sterile 10 pack of WS-1106ST and has a 6 inch length and 0.045 inch diameter. .054 X 7 ST Guide Wire, Part number 45-0031-S, Sterile 10 Pack of WS-1407ST and has a 7 inch length and 0.054 inch diameter. These guide wires are an orthopedic manual surgical instrument.

    Guide wires sized as .045 X 6 were mis-packaged as .054 X 7 guide wires and those sized as .054 X 7 were mis- packaged as .045 X 6 guide wires. There is a possibility that using the incorrect guide wire size can cause health hazards, such as mal or nonunion, need for revision surgery, and histological response (if wire breaks).

  • 2017-02-14TerminatedMixed-up of materials/components

    6-hole Pubic Symphysis plate (PN 70-0451). The pelvic bone plates for the pelvic ring are a series of plates with varying lengths that function as internal fixation devices for fractures, fusions and osteotomies of the pelvic ring. The plates are strategically pre-contoured where beneficial to the application, and they are secured to the bone with 3.5mm non-locking screws. The Acumed pelvic ring plate is the Pubic Symphysis Plate. The Acumed Pelvic Plating System is intended for use by surgeons with orthopedic training and knowledge of the indications and techniques required for fixation. The device is to be implanted by the surgeon in a sterile operating room setting.

    The 6-hole Pubic Symphysis plate (PN 70-0451) is specified to be made of Commercially Pure Titanium (ASTM F67 - CP Grade 4). However, batch 383813 was manufactured out of Titanium Alloy (Ti-6Al- 4V ELI per ASTM F135 Ti alloy) and was distributed.

  • 2014-04-25TerminatedComponent change control

    The Osteo-Clage System consists of stainless steel cable/sleeves and compression plates. . 2.0 mm x 850mm SS Cable/Sleeve; Part Number 01-0020-S 2.0 mm SS Sleeve Only; Part Number 01-0022-S 8, 7 hole, SS compression plate; Part Number 02-2007-S 10, 9 hole, SS compression plate; Part Number 02-2009-S Product Usage: The Osteo-Clage Stainless Steel Bone Plate is an implantable straight, rigid stainless steel plate. It is used in conjunction with 4.5mm Cortical bone screws to provide compression across bone fractures. The Osteo-Clage Cerclage Wire Crimp sleeve is used in conjunction with the bone plate in cerclage fixation procedures

    Manufacturing of these devices with a grade of stainless steel that is not within specifications.