Siemens Healthcare Diagnostics
FDA adverse event reports naming Siemens Healthcare Diagnostics as the device manufacturer, with recall history from the live FDA recall database. Reporter-supplied name as filed: SIEMENS HEALTHCARE DIAGNOSTICS.
- Total reports
- 2,588
- Deaths
- 11
- Injuries
- 22
- Malfunctions
- 2,024
Reports per year
Source: FDA adverse event reports by year received, 2011–2025. Reporting paused during the 2026 MAUDE-to-AEMS transition and has since resumed.
Top device categories
- Analyzer, Chemistry (Photometric, Discrete), For Clinical UseJJE548
- Immunoassay Method, Troponin SubunitMMI445
- Electrode Measurement, Blood-Gases (Pco2, Po2) And Blood PhCHL409
- Method, Enzymatic, Glucose (Urinary, Non-Quantitative)JIL192
- Automated Urinalysis SystemKQO172
- Electrode, Ion Specific, SodiumJGS86
- System, Hemoglobin, AutomatedGKR73
- Colorimeter, Photometer, Spectrophotometer For Clinical UseJJQ63
- System, Test, Human Chorionic GonadotropinDHA50
- Assay, Glycosylated HemoglobinLCP46
Recent recalls
- 2026-07-08Open, ClassifiedUnder Investigation by firm
Atellica CH Enzymatic Hemoglobin A1c (A1c_E). Material Number: 11097536.
The potential for intermittent well-to-well bias on the A1c_E assay on the Atellica CH and Atellica CI analyzer which could cause falsely depressed or falsely elevated HbA1c patient results.
- 2026-06-10Open, ClassifiedUnder Investigation by firm
Siemens Dimension Tacrolimus Flex Reagent Cartridge (TAC), REF DF207, SMN 10700795; enzyme immunoassay
A potential positive bias in quality control (QC) and patient sample results in three lots of the Dimension Tacrolimus (TAC) Flex reagent cartridge.
- 2026-04-29Open, ClassifiedUnder Investigation by firm
epoc BGEM BUN Test Card (25 pk) for the epoc Blood Analysis System; Siemens Material Number (SMN): 10736515;
Use of the affected product can result in discrepant low pH and measured Total Carbon Dioxide (mTCO2) results and corresponding calculated values in arterial, venous, and capillary patient samples. An erroneously low pH or mTCO2 reading can lead to inappropriate treatment of nonexistent acidosis (respiratory of metabolic) or missed diagnosis of alkalosis (a true high pH: respiratory or metabolic alkalosis), potentially causing harm through unnecessary interventions with the former or failure to deliver appropriate treatment with the latter.
- 2026-04-28Open, ClassifiedUnder Investigation by firm
Dimension Creatinine Flex reagent cartridge. Material Number: 10872079.
Siemens Healthcare Diagnostics is recalling certain lots of Dimension Creatinine Flex reagent cartridge (Dimension CRE2) because a potential imprecision in the Dimension CRE2 quality control (QC) and patient sample results using lot numbers GA6307 and BA7005 on the Dimension System. This imprecision may lead to erroneously decreased or increased creatinine patient results
- 2026-03-27Open, ClassifiedProcess control
Atellica CH Enzymatic Hemoglobin A1c (A1c_E); Siemens Material Number (SMN): 11097536;
A potential for depressed results for Atellica CH A1c_E when processing Atellica CH RCRP on the same analyzer. Customers processing A1c_E and RCRP on separate analyzers are not impacted by the recall. The frequency and magnitude of the negative bias and imprecision increase over time and are not consistent with the assay Instructions For Use (IFU). When this issue is present, Quality Control (QC) results demonstrate a negative trend and increased imprecision. The clinical impact of a negative (A1c_E) bias may lead to a delay in diagnosis for diabetes or lead to less-than-optimal treatment for existing diabetes.
- 2026-03-02Open, ClassifiedUnder Investigation by firm
Atellica CH Urine Albumin (UAlb). Material Number: 11537225
Falsely depressed UAlb patient results may occur. Affected samples with any urine albumin concentration above the UAlb measuring interval >40.0 mg/dL may report values between 6.2 mg/dL and 40.0 mg/dL.
- 2025-11-13Open, ClassifiedUnder Investigation by firm
IMMULITE 2000 Oak Mix Specific Allergen; Siemens Material Number (SMN): 10386105; Catalog Number: L2KUN6;
The barcode orientation on affected devices causes incorrect scanning order of tubes within the allergen holder wedge. When using an IMMULITE 2000 / IMMULITE 2000 XPi instrument in combination with a Zebra barcode scanner, the instrument will not correctly recognize the position of tubes within the allergen holder wedge.
- 2025-11-13Open, ClassifiedUnder Investigation by firm
3gAllergy Specific IgE Universal Kit; Kit Component: 3gAllergy Specific IgE Adjustor Antibody (L2UNS1), 3gAllergy Specific IgE Control Antibody (L2UNS2); Siemens Material Number (SMN): 10380875; Catalog Number: L2KUN6;
The barcode orientation on affected devices causes incorrect scanning order of tubes within the allergen holder wedge. When using an IMMULITE 2000 / IMMULITE 2000 XPi instrument in combination with a Zebra barcode scanner, the instrument will not correctly recognize the position of tubes within the allergen holder wedge.
- 2025-11-13Open, ClassifiedUnder Investigation by firm
Food Panel 3 Specific Allergen; Siemens Material Number (SMN): 10385891; Catalog Number: FP3L4;
The barcode orientation on affected devices causes incorrect scanning order of tubes within the allergen holder wedge. When using an IMMULITE 2000 / IMMULITE 2000 XPi instrument in combination with a Zebra barcode scanner, the instrument will not correctly recognize the position of tubes within the allergen holder wedge.
- 2025-10-27Open, ClassifiedUnder Investigation by firm
Assay: IMMULITE 2000 Intact PTH; Test Code: iPT; Siemens Material Number (SMN): (1) 10381441, (2) 10381442; Catalog Number: (1) L2KPP2, (2) L2KPP6;
The potential for falsely depressed Intact PTH patient results at the low end of the assay range, less than or equal to 50 pg/mL (less than or equal to 5.3 pmol/L), when using specific lots identified by the firm on the IMMULITE 2000/IMMULITE 2000 XPi systems. The bias is observed in both serum and plasma samples.
Monitor Siemens Healthcare Diagnostics automatically
DeviceWatch watches FDA adverse events and recalls for the products you care about, summarizes clinical narratives with AI and alerts you when a safety signal emerges.