Spectranetics Corporation

FDA adverse event reports naming Spectranetics Corporation as the device manufacturer, with recall history from the live FDA recall database. Reporter-supplied name as filed: SPECTRANETICS CORPORATION.

Total reports
1,844
Deaths
338
Injuries
1,228
Malfunctions
271

Reports per year

12
13
14
15
16
17
18
19
20
21
22
23
24
25
26

Source: FDA adverse event reports by year received, 2012–2026. Reporting paused twice in 2026 during FDA reporting-system changes and has since resumed.

Top device categories

Recent recalls

  • 2025-02-14Open, ClassifiedDevice Design

    Intact Vascular Tack Endovascular System, to treat vascular dissections with Tack implant(s) following angioplasty: (4F,1.5-4.5mm), 150cm, REF: 154150041; Tack, 4F Gen 1.5, 150cm CE, REF: 154150042; Tack, 4F Gen 1.5, 90cm CE, REF: 154090042 (6F, 3.5 - 6.0mm), 135cm, REF: 156135061; (6F, 4.0 - 8.0mm), 135cm, REF: 206135061; Tack, 6F Gen 2.0, 135cm CE, REF: 206135062; Tack, 6F Gen 1.5, 135cm CE, REF: 156135062; Tack, 6F Gen 2.0, 80cm CE, REF: 206080062; Tack, 6F Gen 1.5, 80cm CE, REF: 156080062

    Use of Tack Endovascular system, designed to treat acute dissections of inner wall or lining of an artery by tacking damaged tissue to inner luminal surface, could result in problems with deployment and stability of device in vessel after deployment, which may cause failure to resolve dissection, migration of implant, bailout stenting, reintervention, unintended removal of tack devices, and ischemia.

  • 2024-12-16Open, ClassifiedDevice Design

    Turbo Elite Laser Atherectomy Catheter Model Number / UDI-DI code / Product Description 414-151 / 989930000531 / 1.4 mm OTW 417-152 / 989930000551 / 1.7 mm OTW 420-006 / 989930000571 / 2.0 mm OTW 423-001 / 989930000591 / 2.3 mm OTW 425-011 / 989930000601 / 2.5 mm OTW 423-135-01 / 989930004171 / 2.3 mm OTW 423-135-02 / 989930004181 / 2.3 mm OTW 425-135-01 / 989930004201 / 2.5 mm OTW 425-135-02 / 989930004211 / 2.5 mm OTW The Turbo-Elite devices are indicated for use in the treatment, including atherectomy, of infrainguinal stenoses and occlusions in humans.

    Due to complaints received for the marker band detaching from the distal tip of the catheter and remaining in the patient as laser catheter was retracted.

  • 2023-12-08Open, ClassifiedPackaging process control

    Spectranetics Turbo-Elite Laser Atherectomy Catheter 2.0 RX REF 420-159 Spectranetics Turbo-Elite Laser Atherectomy Catheter 2.0 OTW REF 420-006 Spectranetics Turbo-Elite Laser Atherectomy Catheter 1.4 RX REF 414-159 Spectranetics Turbo-Elite Laser Atherectomy Catheter 1.7 OTW REF 417-152 The Turbo-Elite devices are indicated for use in the treatment, including atherectomy, of infrainguinal stenoses and occlusions in humans.

    Incorrect product labeling. Exterior product box label does not match internal pouch label.

  • 2022-11-11Open, ClassifiedDevice Design

    Philips Laser System, REF: LAS-100. Used in minimally invasive interventional procedures within the cardiovascular system, and for the removal of problematic pacemaker and defibrillator cardiac leads.

    Laser System may detect Error 106 or Error 108 System Failures that will cause the system to enter non-recoverable safe state. The user will not be able to proceed until the error is cleared. May result in initiation of treatment delay and/or treatment beyond initial scope and/or unable to treat patient.

  • 2017-08-26TerminatedNonconforming Material/Component

    Spectranetics Bridge Occlusion Balloon catheter, Sheath Compatibility 12F, Guidewire Compatibility 0.035in, Working Length 90cm, Balloon Outer Diameter 31mm, Balloon Length 80mm, Rx Only. Product Usage: It is a device used to occlude the vessel and prevent blood loss as the physician preps for surgery resulting from an SVC tear complication of a lead extraction case. It is used for temporary vessel occlusion of the superior vena cava in applications including perioperative occlusion and emergency control of hemorrhage.

    Possible inability to pass the guidewire through the Bridge device, therefore, resulting in a potential delay of treatment.

  • 2017-07-14TerminatedDevice Design

    Spectranetics Turbo-Elite Laser Atherectomy Catheter Peripheral Rapid Exchange Catheters Device is indicated for use in the treatment, including atherectomy, of infrainguinal stenosis and occlusions

    Potential for flouroscopially visible marker band at the tip of the Rapid Exchange Turbo Elite Atherectomy Catheters to become loose or disengaged rom the catheter when the device is in use in an off-label manner.

  • 2016-11-28TerminatedPackaging

    Turbo Elite Atherectomy Catheter. Models: 410-152, 410-154, 414-151, 414-159, 417-152, 417-156, 420-006, 420-159, 423-001, 423-135-01 The Laser Catheters are used in conjunction with the Spectranetics CVX-300 Excimer Laser System and are intended for use in patients with single or multivessel coronary artery disease, either as a stand-alone modality or in conjunction with Percutaneous Transluminal Coronary Balloon Angioplasty (PTCA), and who are acceptable candidates for coronary artery bypass graft (CABG) surgery.

    Spectranetics Corporation announces a voluntary field action for the Turbo Elite Atherectomy Catheter, ELCA Coronary Atherectomy Catheter, and Bridge Occlusion Balloon due to potentially compromised integrity of the outer sterile packaging.

  • 2016-11-28TerminatedPackaging

    ELCA Coronary Atherectomy Catheter. Models: 110-001, 110-002, 110-004, 114-009, 117-016, 117-205, 120-009 The Laser Catheters are used in conjunction with the Spectranetics CVX-300 Excimer Laser System and are intended for use in patients with single or multivessel coronary artery disease, either as a stand-alone modality or in conjunction with Percutaneous Transluminal Coronary Balloon Angioplasty (PTCA), and who are acceptable candidates for coronary artery bypass graft (CABG) surgery.

    Spectranetics Corporation announces a voluntary field action for the Turbo Elite Atherectomy Catheter, ELCA Coronary Atherectomy Catheter, and Bridge Occlusion Balloon due to potentially compromised integrity of the outer sterile packaging.

  • 2016-11-28TerminatedPackaging

    Bridge Occlusion Balloon. Model: 590-001 Temporary vessel occlusion of the superior vena cava in applications including perioperative occlusion and emergency control of hemorrhage. Any use for procedures other than those indicated in the instructions is not recommended.

    Spectranetics Corporation announces a voluntary field action for the Turbo Elite Atherectomy Catheter, ELCA Coronary Atherectomy Catheter, and Bridge Occlusion Balloon due to potentially compromised integrity of the outer sterile packaging.

  • 2011-08-04TerminatedPackage design/selection

    Spectranetics Turbo-Booster Laser Guide Catheter, 7 Fr, REF 518-043, Sterile EO, Spectranetics Corporation, 96 Talamine Court, Colorado Springs, CO 80907. Designed for directing and supporting Spectranetics laser catheters for use in the treatment of infrainguinal stenoses and occlusions.

    Packaging integrity may be compromised, thus sterility can not be assured.

Monitor Spectranetics Corporation automatically

DeviceWatch watches FDA adverse events and recalls for the products you care about, summarizes clinical narratives with AI and alerts you when a safety signal emerges.