Spectranetics
FDA adverse event reports naming Spectranetics as the device manufacturer, with recall history from the live FDA recall database. Reporter-supplied name as filed: SPECTRANETICS.
- Total reports
- 2,144
- Deaths
- 498
- Injuries
- 1,365
- Malfunctions
- 280
Reports per year
Source: FDA adverse event reports by year received, 2005–2022. Reporting paused twice in 2026 during FDA reporting-system changes and has since resumed.
Top device categories
- Drug-Eluting Peripheral Transluminal Angioplasty CatheterONU1,380
- Device, Removal, Pacemaker Electrode, PercutaneousMFA196
- Catheter, Percutaneous, Cutting/ScoringPNO159
- Stylet, CatheterDRB117
- Catheter, Peripheral, AtherectomyMCW71
- Catheter, Percutaneous Transluminal Coronary Angioplasty (Ptca), Cutting/ScoringNWX56
- Catheter, Intravascular Occluding, TemporaryMJN48
- Dilator, Vessel, For Percutaneous CatheterizationDRE44
- Device, Angioplasty, Laser, CoronaryLPC40
- Catheter, PercutaneousDQY26
Recent recalls
- 2025-02-14Open, ClassifiedDevice Design
Intact Vascular Tack Endovascular System, to treat vascular dissections with Tack implant(s) following angioplasty: (4F,1.5-4.5mm), 150cm, REF: 154150041; Tack, 4F Gen 1.5, 150cm CE, REF: 154150042; Tack, 4F Gen 1.5, 90cm CE, REF: 154090042 (6F, 3.5 - 6.0mm), 135cm, REF: 156135061; (6F, 4.0 - 8.0mm), 135cm, REF: 206135061; Tack, 6F Gen 2.0, 135cm CE, REF: 206135062; Tack, 6F Gen 1.5, 135cm CE, REF: 156135062; Tack, 6F Gen 2.0, 80cm CE, REF: 206080062; Tack, 6F Gen 1.5, 80cm CE, REF: 156080062
Use of Tack Endovascular system, designed to treat acute dissections of inner wall or lining of an artery by tacking damaged tissue to inner luminal surface, could result in problems with deployment and stability of device in vessel after deployment, which may cause failure to resolve dissection, migration of implant, bailout stenting, reintervention, unintended removal of tack devices, and ischemia.
- 2024-12-16Open, ClassifiedDevice Design
Turbo Elite Laser Atherectomy Catheter Model Number / UDI-DI code / Product Description 414-151 / 989930000531 / 1.4 mm OTW 417-152 / 989930000551 / 1.7 mm OTW 420-006 / 989930000571 / 2.0 mm OTW 423-001 / 989930000591 / 2.3 mm OTW 425-011 / 989930000601 / 2.5 mm OTW 423-135-01 / 989930004171 / 2.3 mm OTW 423-135-02 / 989930004181 / 2.3 mm OTW 425-135-01 / 989930004201 / 2.5 mm OTW 425-135-02 / 989930004211 / 2.5 mm OTW The Turbo-Elite devices are indicated for use in the treatment, including atherectomy, of infrainguinal stenoses and occlusions in humans.
Due to complaints received for the marker band detaching from the distal tip of the catheter and remaining in the patient as laser catheter was retracted.
- 2023-12-08Open, ClassifiedPackaging process control
Spectranetics Turbo-Elite Laser Atherectomy Catheter 2.0 RX REF 420-159 Spectranetics Turbo-Elite Laser Atherectomy Catheter 2.0 OTW REF 420-006 Spectranetics Turbo-Elite Laser Atherectomy Catheter 1.4 RX REF 414-159 Spectranetics Turbo-Elite Laser Atherectomy Catheter 1.7 OTW REF 417-152 The Turbo-Elite devices are indicated for use in the treatment, including atherectomy, of infrainguinal stenoses and occlusions in humans.
Incorrect product labeling. Exterior product box label does not match internal pouch label.
- 2022-11-11Open, ClassifiedDevice Design
Philips Laser System, REF: LAS-100. Used in minimally invasive interventional procedures within the cardiovascular system, and for the removal of problematic pacemaker and defibrillator cardiac leads.
Laser System may detect Error 106 or Error 108 System Failures that will cause the system to enter non-recoverable safe state. The user will not be able to proceed until the error is cleared. May result in initiation of treatment delay and/or treatment beyond initial scope and/or unable to treat patient.
- 2017-08-26TerminatedNonconforming Material/Component
Spectranetics Bridge Occlusion Balloon catheter, Sheath Compatibility 12F, Guidewire Compatibility 0.035in, Working Length 90cm, Balloon Outer Diameter 31mm, Balloon Length 80mm, Rx Only. Product Usage: It is a device used to occlude the vessel and prevent blood loss as the physician preps for surgery resulting from an SVC tear complication of a lead extraction case. It is used for temporary vessel occlusion of the superior vena cava in applications including perioperative occlusion and emergency control of hemorrhage.
Possible inability to pass the guidewire through the Bridge device, therefore, resulting in a potential delay of treatment.
- 2017-07-14TerminatedDevice Design
Spectranetics Turbo-Elite Laser Atherectomy Catheter Peripheral Rapid Exchange Catheters Device is indicated for use in the treatment, including atherectomy, of infrainguinal stenosis and occlusions
Potential for flouroscopially visible marker band at the tip of the Rapid Exchange Turbo Elite Atherectomy Catheters to become loose or disengaged rom the catheter when the device is in use in an off-label manner.
- 2016-11-28TerminatedPackaging
Turbo Elite Atherectomy Catheter. Models: 410-152, 410-154, 414-151, 414-159, 417-152, 417-156, 420-006, 420-159, 423-001, 423-135-01 The Laser Catheters are used in conjunction with the Spectranetics CVX-300 Excimer Laser System and are intended for use in patients with single or multivessel coronary artery disease, either as a stand-alone modality or in conjunction with Percutaneous Transluminal Coronary Balloon Angioplasty (PTCA), and who are acceptable candidates for coronary artery bypass graft (CABG) surgery.
Spectranetics Corporation announces a voluntary field action for the Turbo Elite Atherectomy Catheter, ELCA Coronary Atherectomy Catheter, and Bridge Occlusion Balloon due to potentially compromised integrity of the outer sterile packaging.
- 2016-11-28TerminatedPackaging
ELCA Coronary Atherectomy Catheter. Models: 110-001, 110-002, 110-004, 114-009, 117-016, 117-205, 120-009 The Laser Catheters are used in conjunction with the Spectranetics CVX-300 Excimer Laser System and are intended for use in patients with single or multivessel coronary artery disease, either as a stand-alone modality or in conjunction with Percutaneous Transluminal Coronary Balloon Angioplasty (PTCA), and who are acceptable candidates for coronary artery bypass graft (CABG) surgery.
Spectranetics Corporation announces a voluntary field action for the Turbo Elite Atherectomy Catheter, ELCA Coronary Atherectomy Catheter, and Bridge Occlusion Balloon due to potentially compromised integrity of the outer sterile packaging.
- 2016-11-28TerminatedPackaging
Bridge Occlusion Balloon. Model: 590-001 Temporary vessel occlusion of the superior vena cava in applications including perioperative occlusion and emergency control of hemorrhage. Any use for procedures other than those indicated in the instructions is not recommended.
Spectranetics Corporation announces a voluntary field action for the Turbo Elite Atherectomy Catheter, ELCA Coronary Atherectomy Catheter, and Bridge Occlusion Balloon due to potentially compromised integrity of the outer sterile packaging.
- 2016-02-05TerminatedError in labeling
2.3mm Turbo-Power OTW, Manual, Model No 423-050 Product Usage The Turbo-Power System (Laser Atherectomy Catheter) is a laser atherectomy device designed for use with the CVX-300" Excimer Laser System. The Turbo-Power Laser Atherectomy Catheter is a sterile, single use, prescription only device used for peripheral atherectomy. Turbo-Power is used exclusively with SPNC s CVX 300" Excimer Laser System and is a Type CF device, Defibrillation proof. Turbo-Power is a laser atherectomy catheter designed for treatment of de novo or restenotic lesions in native infrainguinal arteries and for the treatment of femoropopliteal artery in-stent restenosis (ISR) in bare nitinol stents, with adjunctive Percutaneous Transluminal Angioplasty (PTA). Turbo-Power is used to directionally ablate infrainguinal concentric and eccentric lesions in vessels that are 3.5 mm or greater in diameter. The device is comprised of three parts: the working length of the catheter shaft (also the applied part), the motor drive unit (MDU), and the proximal laser shaft which connects the catheter fiber optics to the CVX-300" Excimer Laser System.
The product is labeled with an expiration date that is past its shelf life.