FDA adverse event reports naming Masimo Corporation as the device manufacturer, with recall history from the live FDA recall database. Reporter-supplied name as filed: MASIMO CORPORATION.

Total reports
2,938
Deaths
73
Injuries
161
Malfunctions
2,644

Reports per year

12
13
14
15
16
17
18
19
20
21
22
23
24
25
26

Source: FDA adverse event reports by year received, 20122026. Reporting paused during the 2026 MAUDE-to-AEMS transition and has since resumed.

Top device categories

Recent recalls

  • 2026-07-02Open, ClassifiedProcess control

    Radius VSM ECG pre-connected Set, REF: 4842, 4695

    Two devices recalled: 1) Electrocardiogram (ECG) electrode assembly ECG feature may incorrectly detect extreme bradycardia, tachycardia and trigger alarms on normal heart rate patients, which may distract clinicians away from management of true positive alarms, which could delay treatment; 2) Small and medium size blood pressure cuffs may contain rough edges, may result in skin irritation/redness.

  • 2026-07-02Open, ClassifiedProcess control

    Radius VSM Disposable NIBP Cuff, REF: 4825, 4826

    Two devices recalled: 1) Electrocardiogram (ECG) electrode assembly ECG feature may incorrectly detect extreme bradycardia, tachycardia and trigger alarms on normal heart rate patients, which may distract clinicians away from management of true positive alarms, which could delay treatment; 2) Small and medium size blood pressure cuffs may contain rough edges, may result in skin irritation/redness.

  • 2024-04-12Open, ClassifiedMaterial/Component Contamination

    Masimo Rad-G, Pulse Oximeter with temperature (W/Sensor), REF:9210, Rx Only,

    Their is a potential that Oximeter may automatically power off and on resulting in loss of monitoring.

  • 2024-04-12Open, ClassifiedMaterial/Component Contamination

    Masimo Rad-G, Pulse Oximeter (W/Sensor), REF:9847, Rx Only,

    Their is a potential that Oximeter may automatically power off and on resulting in loss of monitoring.

  • 2024-04-12Open, ClassifiedMaterial/Component Contamination

    Masimo Rad-G, Pulse Oximeter (W/Patient Cable), REF:9849, Rx Only,

    Their is a potential that Oximeter may automatically power off and on resulting in loss of monitoring.

  • 2024-04-12Open, ClassifiedMaterial/Component Contamination

    Masimo Rad-G, Pulse Oximeter (W/Patient Cable), REF:9895 Rx Only,

    Their is a potential that Oximeter may automatically power off and on resulting in loss of monitoring.

  • 2023-06-21Open, ClassifiedNonconforming Material/Component

    Masimo RD Set TC-I SpO2 Adult Reusable Ear Sensor, REF: 4053

    TC-I tip clip sensor may produce readings outside the accuracy specification.

  • 2023-06-21Open, ClassifiedNonconforming Material/Component

    Masimo LNOP TC-I SpO2, Reusable Ear Sensor, REF: 1794

    TC-I tip clip sensor may produce readings outside the accuracy specification.

  • 2023-06-21Open, ClassifiedNonconforming Material/Component

    Masimo LNCS TC-I SpO2, Reusable Ear Sensor, REF: 1895

    TC-I tip clip sensor may produce readings outside the accuracy specification.

  • 2023-06-21Open, ClassifiedNonconforming Material/Component

    Masimo LNCS TC-I SpO2, Reusable Ear Sensor, REF: 2503

    TC-I tip clip sensor may produce readings outside the accuracy specification.