Monitor, Cardiac (Incl. Cardiotachometer & Rate Alarm)
FDA adverse event reports and recall history for monitor, cardiac (incl. cardiotachometer & rate alarm) (product code DRT), from the public MAUDE corpus and the live FDA recall database.
- Total reports
- 3,123
- Deaths
- 576
- Injuries
- 178
- Malfunctions
- 2,236
Reports per year
Source: FDA adverse event reports by year received, 2012–2026. Reporting paused twice in 2026 during FDA reporting-system changes and has since resumed.
Recent recalls
- 2025-03-06Open, ClassifiedLabeling design
Vios Monitoring System Bedside Monitor Model BSM2050
Batteries may deplete over time while not in use if devices are stored without being plugged in to wall outlet. Depleted batteries may lead to tablet connectivity issues.
- 2025-02-12Open, ClassifiedSoftware design
Vios Monitoring System Bedside Monitor, Model BSM2050, Software Version Numbers 1.54.20 and 1.56.00
A premature failure condition was identified with the L2050R pulse oximeter SpO2 sensor that connects to the L2050G Vios chest sensor device. When a failure occurs, a Pulse Ox Sensor Off warning condition will be incorrectly displayed by the system.
- 2025-01-30Open, ClassifiedSoftware design
muRata Vios Monitoring System Model 2050; bedside cardiac monitor, including cardiotachometer and alarm rate
During the set-up and workflow to begin Vios monitoring, it has been noticed that patient vital signs and ECG waveforms can become distorted and will flicker or flash very fast. This issue only occurs on the Central Station Monitor (CSM) in the patient tiles view and is not seen at any other point during patient monitoring & not on the Bedside Monitor.
- 2025-01-16CompletedDevice Design
muRata Vios Monitoring System Model 2050; bedside cardiac monitor, including cardiotachometer and alarm rate
During the set-up and workflow to begin Vios monitoring, it has been noticed that patient vital signs and ECG waveforms can become distorted and will flicker or flash very fast. This issue only occurs on the Central Station Monitor (CSM) in the patient tiles view and is not seen at any other point during patient monitoring & not on the Bedside Monitor.
- 2014-08-19TerminatedUnknown/Undetermined by firm
Blood pressure (BP) circuit of the ANSAR ANX-3.0 Autonomic Monitor system. The ANX 3.0 system is comprised of these components. 1. Patient Physiological Monitor, 2. Laptop Computer, 3. Stand w/wheels, 4. Patient cables, 5. Software components (Respiratory and Cardiac Spectral Frequency Signal Processor). The different monitor components that can be used in the system are one of the following per system are as follows: Patient Physiological Monitors used: CJPS Vital Pro, Zoe Medical Nightingale Monitoring system, Ivy Biomedical model 405P, Software components: Ansar ANS C 3000. The device is also referred to as the ANS-C3000.
The blood pressure (BP) circuit occasionally fails to inflate the blood pressure cuff and the BP circuit fails to activate, resulting in no BP measured.
- 2012-02-24TerminatedProcess control
V Series Monitor Mindray DS USA, Inc. 800 MacArthur Boulevard. Mahwah, NJ 07430 The Indications for Use for the V Series include the monitoring of the following human physiological parameters: ECG waveform derived from 3, 5, 6 and 12 lead measurements Heart Rate Pulse Oximetry (Sp02) ST Segment Analysis Arrhythmia Detection Non Invasive Blood Pressure (NIBP) Invasive Blood Pressure (IBP) Cardiac Output (CO) Respiratory Gasses Respiration Rate Temperature The V Series Monitor has the capability of performing IV Drug and Hemodynamic Calculations and interfacing with network devices
A system database corruption may occur that causes the V Series Monitor to reset.
- 2005-11-23TerminatedOther
Spectrum Patient Monitor, Physiological, Patient with arrhythmia detection or alamrs. Monitor can monitor, display, trend and print a patient''s physiological parameters. The device has a 12.1 inch color display and has a standard configuration of a 3 or 5 lead ECG, Masimo SET SpO2, non-invasive blood pressure, respiration, continuous temperature and IV Drug Calculations. Optional digital displays are provided for invasive blood pressure (up to four) anesthetic agents, O2 and NO2, ST, and CO2.
Software anomalies which include shut down while printing, invalid diastolic blood pressure display, and incomplete and inaccurate interpretation reports of 12-Lead ECG data.
- 2005-11-23TerminatedOther
Passport 2 with View 12 ECG Analysis Module. It is a transportable, multi-parameter physiological monitor designed to monitor and display the following physiological parameters: ECG, Heart Rate derived from selected sources (Sp)2, ECG, IBP and NIBP), SpO2 level, ST Segment, Arrhythmia, Blood pressure (both invasive and non-invasive), Respiration rate (dirived from ECG or CO2), inspired or expired CO2, temperature , and gases (i.e. five anesthetsia gases, O2, N2O, and CO2)
Software anomalies which include shut down while printing, invalid diastolic blood pressure display, and incomplete and inaccurate interpretation reports of 12-Lead ECG data.
- 2005-09-21TerminatedOther
Panorama Patient Monitoring Network, Cardiac Arrhythmia Monitor.
The software version contains an anomaly which could freeze the unit when the right click button is used on the mouse.
- 2005-08-06TerminatedOther
Panorama Patient Monitoring Network. Cardiac Arrhythmia Monitor.
Upon the new release of software, the firm started receiving reports of unexpected system failures in the database subsystem related to virtual memory pages.
Monitor monitor, cardiac (incl. cardiotachometer & rate alarm) automatically
DeviceWatch watches FDA adverse events and recalls for the products you care about, summarizes clinical narratives with AI and alerts you when a safety signal emerges.