Medline Industries, Inc.
FDA adverse event reports naming Medline Industries, Inc. as the device manufacturer, with recall history from the live FDA recall database. Reporter-supplied name as filed: MEDLINE INDUSTRIES, INC..
- Total reports
- 2,526
- Deaths
- 25
- Injuries
- 652
- Malfunctions
- 1,310
Reports per year
Source: FDA adverse event reports by year received, 2012–2026. Reporting paused during the 2026 MAUDE-to-AEMS transition and has since resumed.
Top device categories
- General Surgery TrayLRO310
- Walker, MechanicalITJ203
- Electrosurgical, Cutting & Coagulation & AccessoriesGEI104
- Wheelchair, MechanicalIOR94
- Pack, Hot Or Cold, DisposableIMD71
- Catheter Care TrayOHR68
- Gauze/Sponge, Internal, X-Ray DetectableGDY60
- Catheter, UrologicalKOD50
- Catheter, Retention Type, BalloonEZL48
- Surgeon'S GlovesKGO45
Recent recalls
- 2020-02-11TerminatedUnder Investigation by firm
Medline HOI LUMBAR REF DYNJ902823G Lot 20AKA895 Expiration 2021-05-31 1 each GTIN (01)10193489219180
The sterile pack inside the Complete Delivery System (CDS) did not go through a complete sterilization cycle, therefore the sterility of these components cannot be guaranteed.
- 2020-02-11TerminatedUnder Investigation by firm
Medline ROBOTIC-LF REF CDS984543B Lot 20AKA927 Expiration 2020-09-30 GTIN (01)10888277056350
The sterile pack inside the Complete Delivery System (CDS) did not go through a complete sterilization cycle, therefore the sterility of these components cannot be guaranteed.
- 2019-08-12TerminatedNonconforming Material/Component
Medline Primary Warmer Pack, Product No. DYNJ52510A. The Medline Primary Warmer Pack contains the recalled Vyaire enFlow Disposable Cartridge, which is the subject of this recall, and the recalled BD Alaris Pump Infusion Set (RES#82951) Product Usage: The Vyaire enFlow Disposable Cartridges contain a heating element that is used to help raise or maintain a patient's body temperature.
The Vyaire enFlow disposable cartridge was recalled due to the potential for unsafe aluminum levels to elute into the infusate. The Use of the BD Alaris Pump Infusion Set may lead to serious adverse events for patients due to the incomplete occlusion caused by variation in tubing wall thickness.
- 2019-08-12TerminatedNonconforming Material/Component
Centurion Convenience Kits, containing BD Alaris Pump Infusion Sets. BD code 11522558 (Centurion code 110931) contained inside kits DYNJ52509A and DYNJ52510A. Product Usage: The Centurion Primary Set Pack and Primary Warmer Pack Convenience Kit helps continuously or intermittently deliver fluids, medications, blood and blood products to adult, pediatric or neonatal patients.
This recall is a sub recall to BD s recent Class I recall for the Alaris Pump Infusion Set due to an issue with the consistency of the inner lumen thickness of the silicone tubing segment which directly impacts amount of occlusion force necessary to fully seal the tube. This defect prevents the pump from complete occlusion and results in the potential for over-infusion of drug product into the patient.
- 2019-07-18Open, ClassifiedDevice Design
Anti-fog solution packaged in a Tyvek peel pouch and it is placed into various kits. Kit are labeled as follows: ROBOTIC GENERAL, LAP CHOLE, GENERAL LAPAROSCOPY PACK-LF, T&A PACK, LAP CHOLE PACK-LF, LAPAROSCOPY PACK-LF, EAR ACCESSORY PACK, RF LAP CHOLEPACK (LCLUI)642-LF, GEN LAPAROSCOPY PACK-LF, LAPAROSCOPY PELVISCOPY PACK, LAP ABDOMINAL CDS-LF, GENERAL LAPAROSCOPY CDS, GYN LAPAROSCOPY CDS, CSMC/ENDOSINUS/NASAL PACK-LF, GENERAL LAPAROSCOPY PACK, GENERAL SURGERY, MODULE TONSIL, MODULE GYN LAP NATALIE, GEN SURGERY LAP CHOLE PACK, T & A CDS, GYN LAPAROSCOPY PACK, GENERAL LAPAROSCOPY, GYN LAPAROSCOPY, TONSIL PACK, LAPAROSCOPY CDS-LF, TRMC GENERAL ENDOSCOPY PACK, GENERAL ENDOSCOPIC PACK-LF, RVMC LAP CHOLE PACK, LAP CHOLE PACK, MH GENERAL LAPAROSCOPY, THORACIC, GB GENERAL ENDO, T & A, DM LAPAROSCOPY PACK, THORACIC ROBOT, LAVH PACK, LAPAROSCOPY, T AND A, SINUS PACK, ROBOTICS PACK-LF, GYN LAPAROSCOPY-LF, LAPAROSCOPIC PACK, GENERAL LAP PACK, ENT PACK, OPEN HEART PK A&B&C, LAPAROSCOPIC, LAP TUBAL LIGATION PACK, ROBOTICS SI, OPEN HEART CDS, LAPAROSCOPY CDS, LAP GASTRIC BY PASS, GENERAL LAPAROSCOPY PK-LF, THORACOTOMY THORACOSCOPY, T AND A COBLATOR, ROBOTICS PACK, TOTAL LAP HYSTERECTOMY CDS, LAPAROSCOPY TRAY-LF, PATEWOOD T AND A PACK, FESS PACK, AMB MSL W INJECTION, LAP CHOLE CDS, NASAL SEPTOPLASTY PACK, ENDOSCOPY PACK, AMB GYN LAPAROSCOPY, GASTRIC BYPASS CDS-LF, MHC LAP CHOLE, HHOR ENT, LAP BARIATRIC, LAPAROSCOPY PACK, MHC OPEN HEART 1 OF 2, BARIATRIC, GENERAL LAP PACK-LF, MAG LAPAROSCOPY CDS, SPRINGHILL LAP CHOLE PACK, BMHM GASTRIC BAND-BYPASS PACK, NASAL PACK, LAPAROSCOPY PACK - OSC, ALT GENERAL LAPAROSCOPY CDS, MER ROBOTIC, JAM/HRZ GENERAL LAPAROSCOPY, ARTHROSCOPY PACK, MAJOR LITHOTOMY SOMC-LF, BARI GASTRECTOMY CDS, LAP GYN PACK-LF, THORACOTOMY PACK-LF, T&A PACK-LF, PELVISCOPY PACK, GENERAL LAPAROSCOPY-LF, ROBOT GYN, MAJOR ENT PACK, TONSIL & ADENOIDS PACK, PROSTATE ROBOTIC, CARDIAC SURGERY CABG PACK-LF, LAP CHOLE TRAY, THORASCOPIC TETHERING OR PACK, ROBOTIC PACK, LAVH, OPEN HEART, LAP CHOLE QVH VER. B, BARIATRIC-LF, T&A TRAY #64-RF, BASIC LAP PACK W TUBING, TONSIL & ADENOID PACK, CUSTOM ENDOSCOPY PACK-LF, FESS TRAY #60-RF, LAP PACK WITHOUT TUBING, NASAL SINUS ENDOSCOPY, DAVINCI, TV LAP PACK-LF, MAD T & A, ROBOTIC GU/GYN, RICH LAVH, GYN ROBOTIC-LF, MAD GYN LAPAROSCOPY, PAD GYN LAPAROSCOPY, OSC GYN LAP, SUB GYN LAPAROSCOPY PACK-LF, LAPAROSCOPY-ROBOT, GYN LAP KIT, GENERAL LAP, LAP CHOLE PACK B10, LAP CHOLE CDS-LF, GYN LAPAROSCOPY PACK-LF, LAP CHOLE SURGICOUNT, DIAGNOSTIC LAP PACK, CABG-VEIN HARVESTING PACK-LF, TONSIL PACK UOPSC-LF, BELLEVUE T&A PACK, BGH 001471 SHOULDER PACK-LF, SCOPE LAP THOR PACK, MAIN/LAPAROSCOPY GYN PACK-LF, LAP CHOLE OR PACK, ENSEMBLE THORACO-LF, LAPAROSCOPIE CHIRURGICALE-LF, MAJOR GYN LAPAROSCOPY CDS, HEPATOBILIAIRE LAPAROSCOPIE-LF, GYNE MAJOR LAPAROSCOPY GRH-LF, LAP CHOLE PACK TBRHSC-LF, MAJOR LAPAROSCOPIC SJHC-LF, LAPAROSCOPY RVHS-LF, LAPAROSCOPY III-LF.
The Anti-Fog Solution may not defog properly due to a degradation in the chemical properties.
- 2018-10-11TerminatedUnder Investigation by firm
Endoscopic Cleaning Brush, single use, sold in kits and labeled as the following: a. Item Number DYK1002DCB, BRUSH, CLEANING, DOUBLE ENDED, W/ HANDLE - 300 EA/CS, 50EA/BX, 6BX/CS; b. Item Number DYK1002DBDE, BRUSH, CLEANING, DBL, DIF ENDS - 500 EA/CS, 50 EA/BX, 10 BX/CS; c. Item Number DYK1002DBSE, BRUSH, CLEANING, DBL, SAME END - 500 EA/CS, 50 EA/BX, 10 BX/CS; d. Item Number DYK1002SBC, BRUSH, CLEANING, SINGLE END - 500 EA/CS, 50 EA/BX, 10 BX/CS
There is potential risk of brush detachment during cleaning. If brush detachment is not identified, there is the potential for the brush to be left within the scope.
- 2017-11-21TerminatedPackaging
Sensicare Green Surgical Glove, PI, LF, PF. Packaged in a poly/poly peel pouch with Sunoco films, sterile. Surgical glove.
Possible open seal on top portion of the package. Could cause breach of sterility.
- 2017-11-18TerminatedEmployee error
MEDLINE PEDI ELBOW CLOSED SUCTION CATHETER, 8Fr, REF DYNCPE8
Products labeled as sterile were distributed prior to sterilization
- 2017-11-18TerminatedEmployee error
MEDLINE DOUBLE SWIVEL CLOSED SUCTION CATHETER, 21.3 in (54 cm) FOR ENDOTRACHEAL TUBE, 12 Fr, REF DYNCSDS12, 1 Each, Sterile
Products labeled as sterile were distributed prior to sterilization
- 2015-08-25TerminatedError in labeling
Central Line >34 Weeks Kit. Cardiology department. The Central Line >34 Weeks Kit (DYNDC1987A) is intended for use on patients greater than 34 weeks of age. The central venous catheter, also called a central line, is a long, thin, flexible tube used to give medicines, fluids, nutrients, or blood products over a long period of time, usually several weeks or more. A catheter is often inserted in the arm or chest through the skin into a large vein. The catheter is threaded through this vein until it reaches a large vein near the heart.
The print plate artwork for this lot was found to state: Central Line <34 Weeks Kit displaying an incorrect sign in front of the 34. The description for this device should have stated Central Line >34 Weeks Kit. The defect may lead to the product to be used on patient population that is <34 weeks rather than intended population of >34 weeks.
Monitor Medline Industries, Inc. automatically
DeviceWatch watches FDA adverse events and recalls for the products you care about, summarizes clinical narratives with AI and alerts you when a safety signal emerges.