Biohorizons Implant Systems

FDA adverse event reports naming Biohorizons Implant Systems as the device manufacturer, with recall history from the live FDA recall database. Reporter-supplied name as filed: BIOHORIZONS IMPLANT SYSTEMS.

Total reports
57,913
Deaths
0
Injuries
57,537
Malfunctions
376

Reports per year

19
20
21
22
23
24
25
26

Source: FDA adverse event reports by year received, 2019–2026. Reporting paused twice in 2026 during FDA reporting-system changes and has since resumed.

Top device categories

Recent recalls

  • 2015-12-07TerminatedEmployee error

    RBT, Internal Implant, Laser-Lok, 5.0 x 15mm, 5.7 Platform, REF LPBR5015, Rx only, Sterile R, BIOHORIZONS(R), Dental Implant

    An incorrect label reading 10.5mm and not the specified 15mm was placed on the implant inner vial packaging.

  • 2015-05-12TerminatedProcess control

    Tapered HD Upgrade Set, REF TSKHDUS, Non-Sterile, Rx Only, Product Usage Usage: Surgical instruments used in preparation for dental implant placement

    BioHorizons Tapered HD Upgrade set was packaged with an incorrect drill component manufactured of stainless steel in place of the correct component manufactured from titanium.

  • 2014-02-20TerminatedMixed-up of materials/components

    External Implant RBT, D3 Threadform 4.0 X 10.5mm, REF 40105D3, STERILE R, Rx Only, BioHorizons(R), 2300 Riverchase Center, Birmingham, AL 35244 Usage: dental

    The body length of the External Implant 40105D3 Lot 1302762 labeled as 10.5mm in length is in fact 12mm in length.

  • 2012-12-19TerminatedComponent design/selection

    AutoTac Delivery Handle, REF 400-200, Rx Only, non-sterile, BIOHORIZONS, BIRMINGHAM, AL 35244. Dental.

    The cleaning instructions provided may not be sufficient to remove residual contaminants after surgical use.

  • 2012-12-19TerminatedComponent design/selection

    Titanium Tack Starter Kit, REF 400-270, Rx Only, non-sterile, BIOHORIZONS, BIRMINGHAM, AL 35244. Dental.

    The cleaning instructions provided may not be sufficient to remove residual contaminants after surgical use.

  • 2010-11-04TerminatedOther

    Single-stage 3.5mm Healing Abutment, 4 mm, REF SYHA40, Rx Only, STERILE R, gamma irradiated, expires 2014-44, CE 0473, BIOHORIZONS, BIRMINGHAM, AL 35244. Endosseous dental implant healing abutment.

    Healing abutment may not fully seat on the implant.

  • 2007-05-11TerminatedOther

    Biohorizons 3.0mm Overdenture Implant System, REF 30120S2, (3 mm x12 mm-2mm collar), Biohorizons Implant Systems, Inc., Birmingham, AL 35243

    Dental implant system is missing ball attachment system.

  • 2007-04-13TerminatedOther

    BioHorizons 0.035 Hex Driver, REF 300-377, BioHorizons Implant Systems, Inc., Birmingham, AL 35243, non-sterile, Rx only, REF 300-377.

    Premature wear; The material from which the hex driver was made was improperly hardened during manufacturing and could lead to premature wear.

  • 2007-04-13TerminatedOther

    BioHorizons 0.050 Hex Driver, Regular, REF 300-350, BioHorizons Implant Systems, Inc., Birmingham, AL 35243, non-sterile, Rx only

    Premature Wear; The material from which the hex driver was made was improperly hardened during manufacturing and could lead to premature wear.

  • 2007-04-13TerminatedOther

    BioHorizons 0.050 Hex Driver, Long, REF 300-351, BioHorizons Implant Systems, Inc., Birmingham, AL 35243, non-sterile, Rx only

    Premature Wear; The material from which the hex driver was made was improperly hardened during manufacturing and could lead to premature wear.