FDA adverse event reports and recall history for implant, endosseous, root-form (product code DZE), from the public MAUDE corpus and the live FDA recall database.
- Total reports
- 3,985,038
- Deaths
- 45
- Injuries
- 3,954,182
- Malfunctions
- 30,089
Reports per year
Source: FDA adverse event reports by year received, 2012–2026. Reporting paused twice in 2026 during FDA reporting-system changes and has since resumed.
Recent recalls
- 2026-09-15Open, ClassifiedUnder Investigation by firm
GM Helix Implant, REF: 109.984;
There is a discrepancy between the product identification on the packaging and the dimensions of the implant contained inside.
- 2026-08-11Open, ClassifiedUnder Investigation by firm
Straumann Bone Level Tapered (BLT) Implant, D 4.1mm RC, SLActive 14mm, Roxolid, Loxim (Article 021.5314); implant, endosseous, root-form
Bone Level Tapered (BLT) Implant, D 4.1mm RC, SLActive 14mm, Roxolid, Loxim may inadvertently contain implants that are 12mm in length instead of 14mm as the labeling would suggest.
- 2025-10-01Open, ClassifiedEnvironmental control
IMPLANT EPIKUT PLUS MT16 3,5X10,0MM, REF: ILM 3510N; IMPLANT EPIKUT PLUS MT16 3.8X11.5MM, REF: ILM 3511N; IMPLANT EPIKUT PLUS MT16 3,5X13,0MM, REF: ILM 3513N; IMPLANT EPIKUT PLUS MT16 3,5X15,0MM, REF: ILM 3515N; IMPLANT EPIKUT PLUS MT16 3,8X10,0MM, REF: ILM 3810N; IMPLANT CM16 3,8 X 11MM, REF: ILM 3811N; IMPLANT EPIKUT PLUS MT16 3,8X15,0MM, REF: ILM 3815N; IMPLANT EPIKUT PLUS MT16 4,0X10,0MM, REF: ILM 4010N; IMPLANT EPIKUT PLUS MT16 4,0X11,5MM, REF: ILM 4011N; IMPLANT EPIKUT PLUS MT16 4,0X13,0MM, REF: ILM 4013N; IMP EPIKUT PLUS LONG MT16 4,0X20,0MM, RES: ILM 4020N; IMPLANT EPIKUT PLUS MT16 4,0X8,5MM, RES: ILM 4085N; IMPLANT EPIKUT PLUS MT16 4,5X13,0MM, REF: ILM 4513N; IMPLANT EPIKUT PLUS MT16 4,5X15,0MM, REF: ILM 4515N; IMPLANT EPIKUT PLUS MT16 4,5X8,5MM, REF: ILM 4585N; IMPLANT EPIKUT PLUS MT16 5,0X10,0MM, REF: ILM 5010N; IMPLANT EPIKUT PLUS MT16 5,0X11,5MM, REF: ILM 5011N; IMPLANT EPIKUT PLUS MT16 4,5X10,0MM, REF: ILM 4510N; IMPLANT EPIKUT PLUS MT16 5,0X13,0MM, RES: ILM 5013N; IMPLANT EPIKUT PLUS MT16 5,0X15,0MM, REF: ILM 5015N; IMPLANT EPIKUT PLUS MT16 5,0X8,5MM, REF: ILM 5085N; IMP EPIKUT PLUS LONG MT16 4,0X18,0MM, REF: ILM 4018N; IMP EPIKUT PLUS LONG MT16 3,8X18,0MM, REF: ILM 3818N; IMPLANT EPIKUT PLUS MT16 4,5X11,5MM, REF: ILM 4511N; IMPLANT EPIKUT MT16 4,5X15,0MM, REF: ILM 4515; IMPLANT EPIKUT MT16 4,5X8,5MM, REF: ILM 4585; IMPLANT EPIKUT MT16 3,8X13,0MM, REF: ILM 3813; IMPLANT EPIKUT MT16 3,8X15,0MM, REF: ILM 3815; IMPLANT EPIKUT MT16 5,0X8,5MM, REF: ILM 5085; IMPLANT EPIKUT MT16 3,8X11,5MM, REF: ILM 3811; IMPLANT EPIKUT PLUS MT16 3,8X20,0MM, REF: ILM 3820N; IMPLANT EPIKUT PLUS MT16 4,5X18,0MM, REF: ILM 4518N; IMPLANT UNITITE MORSE COMPACT 6.0X7MM, REF: UCMC 6007N
Dental implants were imported under temperature and storage conditions that do not comply with the instructions for use and product labeling so there may be packaging damage, which could compromise product quality and performance.
- 2025-05-28Open, ClassifiedUnder Investigation by firm
GM Helix Acqua Implant, Article Number: 140.984
It is possible that a package labelled as an 11.5 mm implant may contain a 13 mm implant instead.
- 2025-05-28Open, ClassifiedUnder Investigation by firm
GM Helix Acqua Implant, Article Number: 140.985
It is possible that a package labelled as an 11.5 mm implant may contain a 13 mm implant instead.
- 2025-02-05Open, ClassifiedProcess control
. Nobel Biocare N1 TiUltra TCC RP 4.0x9mm . Nobel Biocare N1 TiUltra TCC RP 4.0x11mm . Nobel Biocare N1 TiUltra TCC RP 4.0x13mm Nobel Biocare N1 TiUltra TCC implants are intended for use as an endosseous dental implant in the maxilla or mandible for anchoring or supporting dental protheses to restore chewing function
Due to manufacturing issue (unintended by-product of the injection molding process) a sharp pin that may puncture the blister packaging and breaching the sterile barrier of the finished product.
- 2025-01-15Open, ClassifiedProcess control
Implant Epikut S Plus CM 16-Degrees 4,5 X 18,0 mm, REF: ILM 4518N
Dental implant box incorrectly labels the diameter as 4,5 X 18,0 mm, but the internal label correctly labels the diameter as 4,0 X 18,0 mm; if the dentist drills the bone with the larger diameter stated on the box, the smaller diameter implant, will become loose and will not fit, which may necessitate an additional surgery.
- 2023-05-18Open, ClassifiedLabeling Change Control
ET III Nano-HA fixture System ET NH Dental Implant Model # ET3R5010B -Intended for Dental Implant Catalog #: AET3R5010B
Mis-labeled length of the dental implant on the Recall Implant's package. Dental implant size D5.0 x L8.5mm, labeled as D5.0 x L10mm
- 2022-08-23Open, ClassifiedProcess change control
Nobel Biocare N1 TiUltra TCC NP 3.5x13mm
Due to the presence of a burr which may cause an aspiration risk to patient during surgical procedure.
- 2020-05-04TerminatedLabeling mix-ups
NobelParallel Conical Connection NP, 3.75x10mm (Endosseous Dental Implant); REF 37965; UDI (01)07332747091441(10)12129104(17)240203 - Product Usage: are intended to be used in the upper or lower jaw bone (osseointegration) and used for anchoring or supporting tooth replacements to restore chewing function.
The top label of article no. 37965, lot 12129104 (immediate packaging of endosseous dental implants ) may incorrectly indicate an implant length of 7mm, which is shorter than the actual length of the implant (10mm).
Monitor implant, endosseous, root-form automatically