FDA adverse event reports naming Bard Access Systems, Inc. as the device manufacturer, with recall history from the live FDA recall database. Reporter-supplied name as filed: BARD ACCESS SYSTEMS, INC..
- Total reports
- 1,903
- Deaths
- 11
- Injuries
- 450
- Malfunctions
- 1,378
Reports per year
Source: FDA adverse event reports by year received, 2012–2026. Reporting paused twice in 2026 during FDA reporting-system changes and has since resumed.
Top device categories
- Catheter, Intravascular, Therapeutic, Long-Term Greater Than 30 DaysLJS686
- Port & Catheter, Implanted, Subcutaneous, IntravascularLJT417
- Set, Administration, IntravascularFPA288
- Catheter, Intravascular, Therapeutic, Short-Term Less Than 30 DaysFOZ221
- Catheter, Intravascular, DiagnosticDQO107
- Catheter, Hemodialysis, Triple Lumen, Non-ImplantedNIE33
- Catheter, Hemodialysis, ImplantedMSD20
- Midline CatheterPND16
- Non-Coring (Huber) NeedlePTI15
- Introducer, CatheterDYB13
Recent recalls
- 2026-09-11Open, ClassifiedMaterial/Component Contamination
Power-Trialysis Short-Term Straight Dialysis Catheter, REF: 5605150; Power-Trialysis Short-Term Straight Dialysis Catheter, REF: 5605200; Power-Trialysis Short-Term Straight Dialysis Catheter, REF: 5605240; Power-Trialysis Short-Term Straight Dialysis Catheter, REF: 5605300; Power-Trialysis Short-Term Curved Extension Dialysis Catheter, REF: 5615120; Power-Trialysis Short-Term Curved Extension Dialysis Catheter, REF: 5615150; Power-Trialysis Short-Term Curved Extension Dialysis Catheter, REF: 5615200; Power-Trialysis Short-Term Curved Extension Dialysis Catheter, REF: 5615240; Power-Trialysis Short-Term Alphacurve Dialysis Catheter, REF: 5655120; Power-Trialysis Short-Term Alphacurve Dialysis Catheter, REF: 5655150; Power-Trialysis Short-Term Alphacurve Dialysis Catheter, REF: 5655200; Power-Trialysis Short-Term Alphacurve Dialysis Catheter, REF: 5655240; Power-Trialysis Short-Term Straight Dialysis Catheter Full Procedure Tray, REF: 5605200G; Power-Trialysis Slim-Cath Straight Short-Term Dialysis Catheter, REF: 5855200G; Power-Trialysis Slim-Cath Precurved Extension Short-Term Dialysis Catheter, REF: 5865150G; Power-Trialysis Slim-Cath Straight Short-Term Dialysis Catheter, REF: 5855150; Power-Trialysis Slim-Cath Straight Short-Term Dialysis Catheter, REF: 5855200; Power-Trialysis Slim-Cath Straight Short-Term Dialysis Catheter, REF: 5855240; Power-Trialysis Slim-Cath Straight Short-Term Dialysis Catheter, REF: 5855300; Power-Trialysis Slim-Cath Precurved Extension Short-Term Dialysis Catheter, REF: 5865120; Power-Trialysis Slim-Cath Precurved Extension Short-Term Dialysis Catheter, REF: 5865150; Power-Trialysis Slim-Cath Precurved Extension Short-Term Dialysis Catheter, REF: 5865200; Power-Trialysis Slim-Cath Precurved Extension Short-Term Dialysis Catheter, REF: 5865240
this is a downstream recall of class I recall RES 98777
- 2026-09-11Open, ClassifiedMaterial/Component Contamination
DuoGlide Short-Term Straight Dialysis Catheter, REF: 5625150; DuoGlide Short-Term Straight Dialysis Catheter, REF: 5625200; DuoGlide Short-Term Straight Dialysis Catheter, REF: 5625240; DuoGlide Short-Term Straight Dialysis Catheter, REF: 5625300; DuoGlide Short-Term Curved Extension Dialysis Catheter, REF: 5626120; DuoGlide Short-Term Curved Extension Dialysis Catheter, REF: 5626150; DuoGlide Short-Term Curved Extension Dialysis Catheter, REF: 5626200; DuoGlide Short-Term Curved Extension Dialysis Catheter, REF: 5626240; Niagara Dual-Lumen Short-Term Curved Extension Dialysis Catheter, REF: 5766200
this is a downstream recall of class I recall RES 98777
- 2026-08-14Open, ClassifiedComponent change control
BD Needle Kit for Powered Driver 15mm x 15Ga, REF: D015151NK, BD Needle Kit for Powered Driver 25mm x 15Ga, REF: D015251NK, BD Needle Kit for Powered Driver 35mm x 15Ga, REF: D015351NK, BD Needle Kit for Powered Driver 45mm x 15Ga, REF: D015451NK, BD Needle Kit for Powered Driver 55mm x 15Ga, REF: D015551NK
After placement of intraosseous (IO) needle sets, used when intravenous access is difficult or impossible to obtain in emergent, urgent, or medically necessary cases, users may experience difficulty/inability to remove obturator, due to it locking to the needle hub, due to out-of-tolerance dimensions and IFU unclarity, which may result in new needle placement, which may result in delayed therapy
- 2026-07-02Open, ClassifiedNonconforming Material/Component
OTP5000 THORA/PARA TRAY, 5FR, NON-VALVED UDI-DI Code: 0110885403284748 PIG1260T SAFE-T-CENTESIS TRAY 6FR X 16CM UDI-DI Code: 0110885403108365 TPT1000 THORACENTESIS/PARACENTESIS TRAY UDI-DI Code: 0110885403108488 The Acute Drainage devices are indicated for use in removing fluid from either the pleural or peritoneal spaces during an acute drainage / aspiration procedure.
Due to lidocaine ampoules being manufactured under deficient manufacturing practices by manufacturer, lidocaine ampoules are currently being recalled by supplier.
- 2026-07-02Open, ClassifiedNonconforming Material/Component
CK000495A Poly Midline Catheter 4 Fr Single-Lumen UDI-DI Code: 00801741121609 CK000566 Poly Midline Catheter 4 Fr Single-Lumen UDI-DI Code: 00801741108051 CK000566 Poly Midline Catheter 4 Fr Single-Lumen UDI-DI Code: 00801741108051 The Poly Per-Q-Cath Midline catheters are indicated for short or long term peripheral access to the peripheral venous system for selected intravenous therapies and blood sarnpling.
Due to lidocaine ampoules being manufactured under deficient manufacturing practices by manufacturer, lidocaine ampoules are currently being recalled by supplier.
- 2026-07-02Open, ClassifiedNonconforming Material/Component
5625240 DuoGlide Short-Term Straight Dialysis Catheter 13 Fr Dual-Lumen UDI-DI Code: 00801741042119 The intended use of the Short-Term Dialysis Catheter is attaining temporary/short-term (less than 30 days) vascular access for hemodialysis, hemoperfusion, or apheresis therapy via the jugular, subclavian, or femoral vein.
Due to lidocaine ampoules being manufactured under deficient manufacturing practices by manufacturer, lidocaine ampoules are currently being recalled by supplier.
- 2026-07-02Open, ClassifiedNonconforming Material/Component
CK000662 PowerPICC SOLO HF Catheter 5 Fr Triple-Lumen UDI-DI Code: 00801741129674 Catheter stylets provide internal reinforcement to aid in catheter placement.
Due to lidocaine ampoules being manufactured under deficient manufacturing practices by manufacturer, lidocaine ampoules are currently being recalled by supplier.
- 2026-07-02Open, ClassifiedNonconforming Material/Component
1274108D PowerPICC SV Catheter 4 Fr Dual-Lumen REKW2449 00801741087110 3173108D PowerPICC SV Catheter 3 Fr Single-Lumen REKV2227 00801741027536 The PowerPlCC SV catheters are intended for short or long term peripheral access to the central venous system for intravenous therapy and blood sampling.
Due to lidocaine ampoules being manufactured under deficient manufacturing practices by manufacturer, lidocaine ampoules are currently being recalled by supplier.
- 2026-07-02Open, ClassifiedNonconforming Material/Component
5605150 Power-Trialysis Short-Term Straight Dialysis Catheter 13 Fr Triple-Lumen UDI-DI Code: 00801741086953 5605240 Power-Trialysis Short-Term Straight Dialysis Catheter 13 Fr Triple-Lumen UDI-DI Code: 00801741086977 5605300 Power-Trialysis Short-Term Straight Dialysis Catheter 13 Fr Triple-Lumen UDI-DI Code: 00801741086984 5615120 Power-Trialysis Short-Term Curved Extension Dialysis Catheter 13 Fr Triple-Lumen UDI-DI Code: 00801741075087 5615200 Power-Trialysis Short-Term Curved Extension Dialysis Catheter 13 Fr Triple-Lumen UDI-DI Code: 00801741075100 5615200 Power-Trialysis Short-Term Curved Extension Dialysis Catheter 13 Fr Triple-Lumen UDI-DI Code: 00801741075100 5615200 Power-Trialysis Short-Term Curved Extension Dialysis Catheter 13 Fr Triple-Lumen UDI-DI Code: 00801741075100 5655120 Power-Trialysis Short-Term Alphacurve Dialysis Catheter 13 Fr Triple-Lumen UDI-DI Code: 00801741066054 The Power-Trialysis" Short-Term Dialysis Catheter, with a third internal lumen for intravenous therapy, power injection of contrast media, and central venous pressure monitoring, is indicated for use in attaining short-term (less than 30 days) vascular access for hemodialysis, hemoperfusion, and apheresis treatments. The catheter is intended to be inserted in the jugular, femoral, or subclavian vein as required. The maximum recommended infusion rate is 5 mL/sec for power injection of contrast media.
Due to lidocaine ampoules being manufactured under deficient manufacturing practices by manufacturer, lidocaine ampoules are currently being recalled by supplier.
- 2026-07-02Open, ClassifiedNonconforming Material/Component
5855240 Power-Trialysis Slim-Cath Straight Short-Term Dialysis Catheter 12 Fr Triple-Lumen UDI-DI Code: 00801741107177 5855300 Power-Trialysis Slim-Cath Straight Short-Term Dialysis Catheter 12 Fr Triple-Lumen UDI-DI Code: 00801741107184 5865120 Power-Trialysis Slim-Cath Precurved Extension Short-Term Dialysis Catheter 12 Fr Triple-Lumen UDI-DI Code: 00801741107191 5865200 Power-Trialysis Slim-Cath Precurved Extension Short-Term Dialysis Catheter 12 Fr Triple-Lumen UDI_DI Code: 00801741107214 5865240 Power-Trialysis Slim-Cath Precurved Extension Short-Term Dialysis Catheter 12 Fr Triple-Lumen UDI-DI Code: 00801741107221 The Power-Trialysis Slim-Cath Short-Term Dialysis Catheter, with a third internal lumen for intravenous therapy, power injection of contrast media, and central venous pressure monitoring, is indicated for use in attaining short-term (less than 30 days) vascular access for hemodialysis, hemoperfusion, and apheresis treatments. The catheter is intended to be inserted in the jugular, femoral, or subclavian vein as required. The maximum recommended infusion rate is 5 mL/sec for power injection of contrast media.
Due to lidocaine ampoules being manufactured under deficient manufacturing practices by manufacturer, lidocaine ampoules are currently being recalled by supplier.
Monitor Bard Access Systems, Inc. automatically
DeviceWatch watches FDA adverse events and recalls for the products you care about, summarizes clinical narratives with AI and alerts you when a safety signal emerges.