ST. Jude Medical
FDA adverse event reports naming ST. Jude Medical as the device manufacturer, with recall history from the live FDA recall database. Reporter-supplied name as filed: ST. JUDE MEDICAL.
- Total reports
- 20,639
- Deaths
- 491
- Injuries
- 8,257
- Malfunctions
- 11,698
Reports per year
Source: FDA adverse event reports by year received, 2012–2026. Reporting paused twice in 2026 during FDA reporting-system changes and has since resumed.
Top device categories
- Introducer, CatheterDYB5,139
- Device, Hemostasis, VascularMGB2,197
- Catheter, Percutaneous, Cardiac Ablation, For Treatment Of Atrial FibrillationOAE1,983
- Drug Eluting Permanent Right Ventricular (Rv) Or Right Atrial (Ra) Pacemaker ElectrodesNVN1,962
- Implantable Cardioverter Defibrillator (Non-Crt)LWS1,357
- Permanent Pacemaker ElectrodeDTB1,293
- Catheter, Electrode Recording, Or Probe, Electrode RecordingDRF781
- Permanent Defibrillator ElectrodesNVY746
- Pulse Generator, Permanent, ImplantableNVZ636
- System, Hemodynamic, ImplantableMOM603
Recent recalls
- 2025-03-21Open, ClassifiedSoftware design
CardioMEMS Heart Failure (HF) System that consist of: -CardioMEMS Hospital System Model CM3100 -CardioMEMS Backend Web Application Model CM4000 -Merlin.net Patient Care Network (PCN) Heart Failure Web Application Model MN6000 The CardioMEMS" HF System provides pulmonary artery (PA) hemodynamic data used for monitoring and management of heart failure (HF) patients. The system measures changes in pulmonary artery (PA) pressure which physicians use to initiate or modify heart failure treatment.
Due to issues associated with data migration of patient information and results to a Cloud service, the firm has received complaint associated with some patient profile information being duplicated while other patient information is missing.
- 2025-01-17Open, ClassifiedUnder Investigation by firm
Merlin.net Patient Care Network (PCN) Heart Failure Web Application (Model MN6000) (Which interfaces with CardioMEMS" Hospital System model CM3100) The CardioMEMS" HF System provides pulmonary artery (PA) hemodynamic data used for monitoring and management of heart failure (HF) patients. The system measures changes in pulmonary artery (PA) pressure which physicians use to initiate or modify heart failure treatment.
Due to a data migration from on-premises server to the cloud environment, some customers reported that they were not able to transmit readings.
- 2025-01-17Open, ClassifiedUnder Investigation by firm
CARDIOMEMS HF PRESSURE MEASUREMENT SYSTEM CardioMEMSTM HF System Patient Electronics System (PES) REF CM1100 Merlin.net Patient Care Network (PCN) Heart Failure Web Application (Which interfaces with CardioMEMSTM HF System Patient Electronics System (PES) and CardioMEMSTM HF System Hospital Electronics System (HES)). Model Number MN6000
As a result of a cloud data migration of Patient and Hospital Electronic Systems (PES and HES) reverted to an outdated configuration causing incorrect/inaccurate pulmonary artery (PA) pressure readings.
- 2025-01-17Open, ClassifiedUnder Investigation by firm
CARDIOMEMS HF PRESSURE MEASUREMENT SYSTEM CardioMEMSTM HF System Hosptial Electronics System (PES) REF CM3000 Merlin.net Patient Care Network (PCN) Heart Failure Web Application (Which interfaces with CardioMEMSTM HF System Patient Electronics System (PES) and CardioMEMSTM HF System Hospital Electronics System (HES)). Model Number MN6000
As a result of a cloud data migration of Patient and Hospital Electronic Systems (PES and HES) reverted to an outdated configuration causing incorrect/inaccurate pulmonary artery (PA) pressure readings.
- 2024-07-12Open, ClassifiedUnder Investigation by firm
St. Jude Medical Agilis NxT Steerable Introducer, REF 408309
One lot of product has dilators that are too short and will not extend outside the introducer sheath.
- 2024-01-25Open, ClassifiedUnder Investigation by firm
TactiFlex Ablation Sensor Enabled Ablation Catheter, Models A-TFSE-FJ, 7.5 F shaft and an 8F distal section, Sterile.
When the catheters are used with the EnSiteX EP System, the system does not correctly recognize the catheter as the appropriate product model and instead reads and displays it as a different model. This results in some features specific to the catheter do not appear on the display and the catheter image may also appear inverted.
- 2023-11-03Open, ClassifiedDevice Design
CardioMEMS Patient Electronic System (PES), Model Number CM1100. Used for wirelessly measuring and monitoring pulmonary artery pressure and heart rate.
Potential for damaged and frayed power connector plug with repeated bending or manipulation beyond 90 degrees.
- 2023-03-06Open, ClassifiedDevice Design
CardioMEMS HF System PA Sensor and Delivery System, Model Number CM2000, The CardioMEMS HF System provides pulmonary artery (PA) hemodynamic data used for the monitoring and management of heart failure (HF) patients. The system measures changes in PA pressure which physicians use to initiate or modify heart failure treatment.
Select CardioMEMS PA Sensors (Model CM2000) operate outside of the intended frequency range at higher elevations when readings are taken over approximately 2,000 ft. (610 meters) above sea level; operation outside of the intended radiofrequency has the potential to result in inaccurate readings or sensor signal acquisition difficulties.
- 2023-03-06Open, ClassifiedDevice Design
CardioMEMS HF System PA Sensor and Delivery System, Model Number CM3000, The CardioMEMS HF System provides pulmonary artery (PA) hemodynamic data used for the monitoring and management of heart failure (HF) patients. The system measures changes in PA pressure which physicians use to initiate or modify heart failure treatment.
Select CardioMEMS PA Sensors (Model CM2000) operate outside of the intended frequency range at higher elevations when readings are taken over approximately 2,000 ft. (610 meters) above sea level; operation outside of the intended radiofrequency has the potential to result in inaccurate readings or sensor signal acquisition difficulties.
- 2023-03-06Open, ClassifiedDevice Design
CardioMEMS HF System PA Sensor and Delivery System, Model Number CM3100, The CardioMEMS HF System provides pulmonary artery (PA) hemodynamic data used for the monitoring and management of heart failure (HF) patients. The system measures changes in PA pressure which physicians use to initiate or modify heart failure treatment.
Select CardioMEMS PA Sensors (Model CM2000) operate outside of the intended frequency range at higher elevations when readings are taken over approximately 2,000 ft. (610 meters) above sea level; operation outside of the intended radiofrequency has the potential to result in inaccurate readings or sensor signal acquisition difficulties.
Monitor ST. Jude Medical automatically
DeviceWatch watches FDA adverse events and recalls for the products you care about, summarizes clinical narratives with AI and alerts you when a safety signal emerges.