Medtronic Neurosurgery
FDA adverse event reports naming Medtronic Neurosurgery as the device manufacturer, with recall history from the live FDA recall database. Reporter-supplied name as filed: MEDTRONIC NEUROSURGERY.
- Total reports
- 7,942
- Deaths
- 101
- Injuries
- 3,105
- Malfunctions
- 3,972
Reports per year
Source: FDA adverse event reports by year received, 2012–2026. Reporting paused twice in 2026 during FDA reporting-system changes and has since resumed.
Top device categories
- Shunt, Central Nervous System And ComponentsJXG6,592
- Device, Monitoring, Intracranial PressureGWM524
- Dura SubstituteGXQ199
- Plate, Fixation, BoneHRS163
- Plate, BoneJEY121
- Screw, Fixation, BoneHWC116
- Endoscope, NeurologicalGWG31
- Plate, Cranioplasty, Preformed, Non-AlterableGXN29
- Port & Catheter, Implanted, Subcutaneous, IntraventricularLKG27
- Catheter, Percutaneous, Intraspinal, Short TermMAJ20
Recent recalls
- 2026-07-21Open, ClassifiedProcess control
Ventriculostomy Kit, REF: 46154
Ventriculostomy devices, used during ventriculostomy procedures to gain access to the ventricular system, may exhibit endotoxin levels that exceed the acceptable limit for devices that come into contact with cerebrospinal fluid; endotoxin exposure can cause an acute inflammatory process.
- 2024-12-19Open, ClassifiedUnder Investigation by firm
Becker External Drainage and Monitoring System: 24146 EDMS 24146 BECKER NO Y-SITE 25120 EDMS II 25120 BECKER W/1-WAY VALVE 26040 KIT 26040 BECKER EDMS II 27609 BECKER 27609 W/NEEDLESLESS INJ. SITE 27670 BECKER 27670 STOP BELOW DC NDL-LS IN 27672 BECKER 27672 ONEWAY VLV Y-SITE PT LN 27702 EDMS 27702 EURO BECKER II GR PT LN 27761 BECKER 27761 STOP BCNDLESS PATLN 24 27767 BECKER 27767 NO STPCOCK ON PTLN 63 27779 EDMS 27779 BECKER BC NDLESS BOND CONN 27811 EDMS 27811 BECKER GRN PL VCATH 27931 EDMS 27931 BECKER GS TUBING SMARTSITES 46128 EDMS 46128 BECKER II BLUE PT LN 46129 EDMS 46129 EURO BECKER II BLUE PT LN The Becker External Drainage and Monitoring System (Becker EDMS) is a closed system for: 1. Draining cerebrospinal fluid (CSF) from the lateral ventricles of the brain or the lumbar subarachnoid space. 2. Monitoring CSF pressure and flow rate from the lateral ventricles of the brain and the lumbar subarachnoid space.
Due to complaints received reporting cracks and/or leaks of the stopcocks associated with the external drainage and monitoring system (EDMS).
- 2024-12-19Open, ClassifiedUnder Investigation by firm
Exacta External Drainage and Monitoring System: 27581 KIT 27581 EXACTA W/EDM VCATH 35CM 27636 EDM 27636 EXACTA W/BRAIDED CORD LOCK 27666 EDM 27666 EXCTA W GLUE STPCK GR PT LN 27732 EDM 27732 EXACTA W/NDL-LS INJ. ST W/CAP 27785 EDMS 27785 EXACTA 50ML BC NDLESS INJ 27795 EDMS 27795 EXACTA 100ML CATH 27861 EDMS 27861 EXACTA 50ML ANTIRFLUX GRNPL 46700 SYSTEM 46700 EXACTA DISP. DRAINAGE 46705 SYSTEM 46705 EXACTA DRAINAGE 100ML The Exacta external drainage and monitoring system (EDMS) is a system for externally draining and monitoring cerebrospinal fluid (CSF) and monitoring intracranial pressure (ICP).
Due to complaints received reporting cracks and/or leaks of the stopcocks associated with the external drainage and monitoring system (EDMS).
- 2024-02-27Open, ClassifiedUnder Investigation by firm
Medtronic Duet External Drainage and Monitoring System, Interlink Injection Sites, REF 46913, Sterile EO, Rx Only. Used to drain cerebrospinal fluid (CSF) as a means to reduce intracranial pressure and CSF volume.
Potential for catheter disconnection from the patient line stopcock connectors.
- 2024-02-27Open, ClassifiedUnder Investigation by firm
Medtronic Duet External Drainage and Monitoring System, SmartSite, Injection Sites, REF 46914, Sterile EO, Rx Only. Used to drain cerebrospinal fluid (CSF) as a means to reduce intracranial pressure and CSF volume.
Potential for catheter disconnection from the patient line stopcock connectors.
- 2024-02-27Open, ClassifiedUnder Investigation by firm
Medtronic Duet External Drainage and Monitoring System, Interlink Injection Sites, Ventricular Catheter, REF 46915, Sterile EO, Rx Only. Used to drain cerebrospinal fluid (CSF) as a means to reduce intracranial pressure and CSF volume.
Potential for catheter disconnection from the patient line stopcock connectors.
- 2024-02-27Open, ClassifiedUnder Investigation by firm
Medtronic Duet External Drainage and Monitoring System, SmartSite Injection Sites, Ventricular Catheter, REF 46916, Sterile EO, Rx Only. Used to drain cerebrospinal fluid (CSF) as a means to reduce intracranial pressure and CSF volume.
Potential for catheter disconnection from the patient line stopcock connectors.
- 2024-02-27Open, ClassifiedUnder Investigation by firm
Medtronic Duet External Drainage and Monitoring System, Interlink Injection Sites, Lumbar Catheter, REF 46917, Sterile EO, Rx Only. Used to drain cerebrospinal fluid (CSF) as a means to reduce intracranial pressure and CSF volume.
Potential for catheter disconnection from the patient line stopcock connectors.
- 2023-08-17Open, ClassifiedLabeling Change Control
Medtronic REF 46915 Duet External Drainage and Monitoring system, Interlink Injection sites, Ventricular Catheter, STERILE EO, Rx Only
Product labeling contains incorrect expiration date
- 2023-07-20Open, ClassifiedProcess change control
Durepair Dura Regeneration Matrix: DUREPAIR DURA SUBSTITUTE 2 X 2, 61100; DUREPAIR DURA SUBSTITUTE 3 X 3, 61105; DUREPAIR DURA SUBSTITUTE 1 X 3, 61106; DUREPAIR DURA SUBSTITUTE 4 X 5, 61110; DUREPAIR DURA SUBSTITUTE 1 X 1, 61111; DURA 62100 SUBSTITUTE DUREPAIR 2X2IN NCE, 62100; DURA 62105 SUBSTITUTE DUREPAIR 3X3IN NCE, 62105; DURA 62106 SUBSTITUTE DUREPAIR 1X3IN NCE, 62106; DURA 62110 SUBSTITUTE DUREPAIR 4X5IN NCE, 62110; DURA 62111 SUBSTITUTE DUREPAIR 1X1IN NCE, 62111; DURA 62158 SUBSTITUTE DUREPAIR 5X8IN NCE, 62158.
Dura regeneration matrix may have out-of-specification endotoxin levels due to issues with in-process and finished goods endotoxin testing, which may present clinically with signs and symptoms of an acute inflammatory process, comparable to infection.
Monitor Medtronic Neurosurgery automatically
DeviceWatch watches FDA adverse events and recalls for the products you care about, summarizes clinical narratives with AI and alerts you when a safety signal emerges.