Skip to main content

Beta Bionics Inc.

FDA adverse event reports naming Beta Bionics Inc. as the device manufacturer, with recall history from the live FDA recall database. Reporter-supplied name as filed: BETA BIONICS INC..

Total reports
37,340
Deaths
13
Injuries
6,670
Malfunctions
30,657

Reports per year

24
25
26

Source: FDA adverse event reports by year received, 2024–2026. Reporting paused twice in 2026 during FDA reporting-system changes and has since resumed.

Top device categories

Recent recalls

  • 2026-06-18Open, ClassifiedSoftware design

    iLet Bionic Pancreas, REF: BB1001

    The reason for the recall is: it was found in version 3.3.6 of the iLet ACE Pump firmware and all previous releases that a screen unlock failure could occur when the user successfully slides the unlock slider on the Lock Screen, no screen transition occurs, and the user remains on the Lock Screen. Because the user cannot exit the Lock Screen, the user is unable to perform a cartridge change or meal announcement. If this occurs and therapy is in progress, therapy will continue normally until the insulin cartridge is depleted. The user will be unable to perform a cartridge change or a meal announcement and will be stuck on the screen until the battery fully drains. This can lead to hyperglycemia.

  • 2026-04-29Open, ClassifiedSoftware change control

    iLet Bionic Pancreas, REF: BB1001

    insulin pump software versions 1.4.2, and 1.4.3 issue with Dexcom Continuous Glucose Monitoring (CGM) G7 sensor may result in delayed CGM reading then switch to non-CGM dosing, leading to only basal/requested meal doses provided, no correction doses/insulin reductions/suspensions for high/low glucose unless blood glucose entered for sensor life or replacement. Potential health risks to users include severe hyperglycemia with and without DKA and severe hypoglycemia.

  • 2026-04-10Open, ClassifiedSoftware design

    iLet Ace Pump Kit REF: BB1001 iLet Dosing Decision Software

    it was found that in versions 1.3.7, 1.4.2, and 1.4.3, the Lock Screen and Limited Access Passcode Screen on the iLet graphical user interface (GUI) include certain icons displayed in the status bar that are active, thereby allowing the user to bypass those screens when those icons on the status bar are pressed, allowing unauthorized access while the device is in Limited Access Mode. A Health Risk associated with Limited access mode includes severe hypoglycemia due to unauthorized access to the iLet if someone were to make unauthorized meal announcements or stopped insulin delivery.

Monitor Beta Bionics Inc. automatically

DeviceWatch watches FDA adverse events and recalls for the products you care about, summarizes clinical narratives with AI and alerts you when a safety signal emerges.