Cardiovascular Procedure Kit
FDA adverse event reports and recall history for cardiovascular procedure kit (product code OEZ), from the public MAUDE corpus and the live FDA recall database.
- Total reports
- 1,609
- Deaths
- 17
- Injuries
- 142
- Malfunctions
- 1,420
Reports per year
Source: FDA adverse event reports by year received, 2012–2026. Reporting paused twice in 2026 during FDA reporting-system changes and has since resumed.
Recent recalls
- 2026-10-15Open, ClassifiedUnder Investigation by firm
Medline surgical convenience kits labeled as: 1) OPEN HEART CDS, Medline product number/SKU CDS840094R; 2) OPEN HEART CDS, Medline product number/SKU CDS840171AG; 3) MHC AV FISTULA, Medline product number/SKU DYNJ903705K; 4) PERIPHERAL VASC MAJR-LF, Medline product number/SKU CDS840379O; 5) MINOR VASCULAR PACK-LF, Medline product number/SKU DYNJ0349727D; 6) SJHC VASCULAR PK-LF, Medline product number/SKU DYNJ19906L; 7) CABG PACK-LF, Medline product number/SKU DYNJ0824648K; 8) PERIPHERAL VASC MNR-LF, Medline product number/SKU DYNJ22721N; 9) HEART A PACK, Medline product number/SKU DYNJ0362405S; 10) OPEN HEART, Medline product number/SKU DYNJ907676I; 11) FEM POP MARYVIEW, Medline product number/SKU DYNJ911714; 12) CABG PACK, Medline product number/SKU DYNJ906346G; 13) DEBOER HEART MAIN, Medline product number/SKU DYNJ907914I; 14) OPEN HEART A & B PACK, Medline product number/SKU DYNJ9718008AU; 15) OPEN HEART, Medline product number/SKU DYNJ911483A; 16) CABG ACCESSORY PACK, Medline product number/SKU DYNJ59265; 17) HEART, Medline product number/SKU DYNJ908779B; 18) CARDIOVASCULAR PACK, Medline product number/SKU DYNJ69507F; 19) OFF PUMP CABG CDS, Medline product number/SKU CDS840087AN; 20) PACK CABG CHRG, Medline product number/SKU DYNJ905683D; 21) HEART CDS, Medline product number/SKU CDS840179N;
Medical convenience kits were distributed containing cannula components which do not conform to ISO 80369-7 dimensional requirements and may contribute to leaking or breaking during use.
- 2026-10-07Open, ClassifiedProcess change control
ADULT HEART TRAY SHANDS JACKS; Model/Item Number (Kit): SHND419-08;
Product may be potentially contaminated with a lubricant used during the manufacturing process.
- 2026-10-07Open, ClassifiedProcess change control
ENDOVASCULAR PACK; Model/Item Number (Kit): VAPX014-04;
Product may be potentially contaminated with a lubricant used during the manufacturing process.
- 2026-10-07Open, ClassifiedProcess change control
PACK OPEN HEART CFH; Model/Item Number (Kit): 1. UFCF004-06, 2. UFCF004-07;
Product may be potentially contaminated with a lubricant used during the manufacturing process.
- 2026-10-07Open, ClassifiedProcess change control
ROBOTIC PROSTATECTOMY PACK; Model/Item Number (Kit): NAMC423-11;
Product may be potentially contaminated with a lubricant used during the manufacturing process.
- 2026-09-25Open, ClassifiedUnder Investigation by firm
Medical convenience kits containing BD CliniClean Pericare Wipes within BD Urinary Catheter Trays CARDIAC HEART BUNDLE NS Model No. LMCH99P OPEN HEART 2 RCH 0248495 Model No. RCOH62C
Kits contain manufacturer-recalled perineal care (pericare) wipes within urinary catheter trays, which may be contaminated with a lubricant used during the manufacturing process. Use of a contaminated wipe may lead to localized skin effects such as irritation, erythema, or mild inflammation. Failure to perform pericare due to disposal of contaminated wipes may increase risk of localized infection or catheter-associated urinary tract infection (CAUTI).
- 2026-09-14Open, ClassifiedNonconforming Material/Component
Medline Convenience Kits: 1) OPEN HEART ADULT, Catalog Number: CDS840396Y; 2) FULL LINE ANEURYSM CDS, Catalog Number: CDS983672O; 3) NON STERILE CHEST TUBE REMOVAL, Catalog Number: DYNDA1080
The kits contain certain lots of sterile applicators which may contain fungal contamination that may occur under certain environmental conditions, allowing the growth of Aspergillus penicillioides. Contamination of skin preparation products with Aspergillus penicillioides may lead to serious adverse health consequences, including systemic infection, sepsis, illness, and death.
- 2026-09-03Open, ClassifiedProcess change control
Presource Packs Containing CliniClean Pericare Wipes within BD Urinary Catheter Trays: 1) KIT, GVI OPEN HEART A B , Catalog Number: PCVNCG540; 2) KIT, GVI OPEN HEART A B , Catalog Number: PCVNCG542; 3) KIT, GVI OPEN HEART A B , Catalog Number: PCVNCG55I; 4) KIT, BLO BASIC OPEN HEART , Catalog Number: PVCGBOB10; 5) KIT, BLO BASIC OPEN HEART , Catalog Number: PVCGBOB10; 6) KIT, BLO BASIC OPEN HEART , Catalog Number: PVCGBOB12; 7) KIT, BLO BASIC OPEN HEART , Catalog Number: PVCGBOB17; 8) KIT, OPEN HEART CON , Catalog Number: PVCGOHCOH; 9) KIT,OPEN HEART ADULT MDST , Catalog Number: PVCGOHCPA; 10) KIT, CABG , Catalog Number: PVHDCBAGK; 11) KIT, ORP CABG , Catalog Number: PVHDCGVCP; 12) KIT, ORP CABG , Catalog Number: PVHDCGV40; 13) KIT, VALVE , Catalog Number: PVHDVAAGH; 14) KIT, ORP VALVE , Catalog Number: PVHDVPVCQ; 15) KIT, ORP VALVE , Catalog Number: PVHDVPV43; 16) KIT, MAJOR CARDIAC , Catalog Number: PVOCMGJ36; 17) KIT, OPEN HEART DH , Catalog Number: PVOCOHNHE; 18) KIT, OPEN HEART , Catalog Number: PVOCOH12O; 19) KIT, CAROTID ENDARTERECTOMY , Catalog Number: PVVMCV07E; 20) KIT, FEM POP BARNES JEW , Catalog Number: PVVMFP22R; 21) KIT, FEM POP BARNES JEW , Catalog Number: PVVMFP245; 22) KIT, THORACIC BARNES JEWISH , Catalog Number: PVVMTH22J; 23) KIT, THORACIC OUTLET SYNDROME , Catalog Number: PVVMTO22R; 24) KIT, THORACIC OUTLET SYNDROME , Catalog Number: PVVMTO241; 25) KIT, THORACIC OUTLET SYNDROME , Catalog Number: PVVMTO242; 26) KIT, THORACIC , Catalog Number: PVVXTHLCG; 27) KIT,OPEN HEART BASIC PRESBYTER, Catalog Number: PVV2CC10R; 28) KIT,OPEN HEART BASIC PRESBYTER, Catalog Number: PVV2CC10S; 29) KIT, MAJOR VASC, PRESBYTERIAN , Catalog Number: PVV2MJ01M; 30) KIT, CARDIAC VALVE , Catalog Number: PVV207962; 31) KIT, CARDIAC VALVE , Catalog Number: PVV207963; 32) KIT, CARDIAC VALVE , Catalog Number: PVV207964; 33) KIT, CARDIAC CABG , Catalog Number: PVV293340; 34) KIT, CARDIAC CABG , Catalog Number: PVV293362; 35) KIT, CARDIAC CABG , Catalog Number: PVV293363; 36) KIT, PUH CARDIAC CABG , Catalog Number: PVX4CAP14; 37) KIT, PUH CARDIAC , Catalog Number: PVX4CRPR7; 38) KIT, EAS THORACIC ABDOMINAL , Catalog Number: PVX4THEAA; 39) KIT, CV , Catalog Number: PV15CGSPF; 40) KIT, CV , Catalog Number: PV15CGSPG; 41) KIT,MAJOR VASCULAR , Catalog Number: PV15MJSPD; 42) KIT, OPEN HEART SET UP , Catalog Number: PV24OHN29; 43) KIT, OPEN HEART , Catalog Number: PV29OHMME; 44) KIT, OPEN HEART , Catalog Number: PV3LOHSGJ; 45) KIT, MER THORACOTOMY CHEST , Catalog Number: PV33TCMYB; 46) KIT, MER THORACOTOMY CHEST , Catalog Number: PV33TCMY3; 47) KIT, BASIC OPEN HEART , Catalog Number: PV40OHAR47; 48) KIT, BASIC OPEN HEART , Catalog Number: PV40OHAR48; 49) KIT, BASIC OPEN HEART , Catalog Number: PV40OHAR49; 50) KIT, OPEN HEART , Catalog Number: PV40OHJUD; 51) KIT, MODULE OPEN HEART , Catalog Number: PV60OH15F; 52) CV W AUX PACK 2 OF 2 CMC , Catalog Number: SCVCGPAACD; 53) THORACIC ROBOTIC PACK CMC , Catalog Number: SCVCGTRACI; 54) CV PACK 2 OF 2 GSH , Catalog Number: SCVCGVCG17; 55) CV PACK 2 OF 2 GSH , Catalog Number: SCVCGVCG18; 56) CV PACK 2 OF 2 SHER , Catalog Number: SCVCGVCS16
The Urinary Catheter Trays contain CliniClean Pericare Wipes which may potentially be contaminated with a lubricant used during the manufacturing process. If a contaminated wipe is used on a patient, localized skin effects may occur. These may include irritation, erythema, or mild inflammation.
- 2026-08-31Open, ClassifiedNonconforming Material/Component
Medline Convenience Kits: 1) CDS840396X, Catalog Number: CDS840396X; 2) CDS840396Y, Catalog Number: CDS840396Y; 3) CDS983348AA, Catalog Number: CDS983348AA; 4) CDS983348AB, Catalog Number: CDS983348AB; 5) CDS983672O, Catalog Number: CDS983672O; 6) CDS983672P, Catalog Number: CDS983672P; 7) DYKM1982, Catalog Number: DYKM1982; 8) DYNDA1080, Catalog Number: DYNDA1080; 9) DYNJ67490C, Catalog Number: DYNJ67490C; 10) DYNJ907400D, Catalog Number: DYNJ907400D; 11) DYNJ908990A, Catalog Number: DYNJ908990A
The kits contain BD ChloraPrep Clear - 1 mL and FREPP Clear 1.5 mL Applicators which have a potential breach of sterility in the packaging, due to wrinkles in the paper lidding which may extend to the seal area. If the sterile barrier is compromised, patients and users may be exposed to microbial contamination. Potential health consequences may include no injury, localized infection, or, less commonly, more serious infection requiring medical treatment, antimicrobial therapy, procedural intervention, or hospitalization. In rare cases, particularly in critically ill or immunocompromised patients, severe infection could become life-threatening.
- 2026-08-31Open, ClassifiedNonconforming Material/Component
Medline Convenience Kits containing BD ChloraPrep Clear - 1mL Applicators OPEN HEART CDS983348AA CDS983348AB
Downstream recall - manufacturer recalled specific lots of BD ChloraPrep Clear - 1mL Applicators. Affected product may exhibit an open or incomplete seal on the packaging of the applicator. Use of potentially contaminated applicator may lead to localized skin or soft tissue infection, or systemic infection or infectious complications.
Monitor cardiovascular procedure kit automatically