Skip to main content
OCXClass 2

Endoscopic Irrigation/Suction System

FDA adverse event reports and recall history for endoscopic irrigation/suction system (product code OCX), from the public MAUDE corpus and the live FDA recall database.

Total reports
277
Deaths
0
Injuries
28
Malfunctions
242

Reports per year

12
13
14
15
16
17
18
19
20
21
22
23
24
25
26

Source: FDA adverse event reports by year received, 2012–2026. Reporting paused twice in 2026 during FDA reporting-system changes and has since resumed.

Recent recalls

  • 2026-05-01Open, ClassifiedComponent change control

    ERBEFLO CleverCap: Hybrid Tubing/Cap Set for Olympus Scopes, 20325-201; ERBEFLO CleverCap Hybrid Tubing/Cap Set for Fujifilm Scopes, REF: 20325-203;

    Devices providing sterile water/CO2/air to endoscopes were manufactured with a distal irrigation segment connector configuration that may be more susceptible to unintended water flow from distal tip under unsupported third-party connector use conditions, which may lead to water aspiration, which may progress to aspiration pneumonia, acute respiratory distress syndrome, or respiratory failure.

  • 2026-05-01Open, ClassifiedComponent change control

    ERBEFLO 2, Endoscopy Pump Tubing/Cap Set, REF: 20325-222

    Devices providing sterile water/CO2/air to endoscopes were manufactured with a distal irrigation segment connector configuration that may be more susceptible to unintended water flow from distal tip under unsupported third-party connector use conditions, which may lead to water aspiration, which may progress to aspiration pneumonia, acute respiratory distress syndrome, or respiratory failure.

  • 2022-10-07Open, ClassifiedProcess control

    Hobbs Medical Spray Catheter: The Mistifier: 2.6mm 260cm Disposable For endoscopy procedures Ref: 2190

    Device label display an incorrect expiration date, extends the shelf life of the product. Affected product distributed in the United States from 3/25/2018 to 9/28/2020, expiration dates between 2022-11-01 and 2025-09-01 (Devices have a lot number ending in R, or are kits containing at least 1 device with a lot number ending in R.)

  • 2022-10-07Open, ClassifiedProcess control

    Hobbs Medical Spray Catheter: The Mistifier: 2.6mm 165cm Disposable For endoscopy procedures Ref: 2191

    Device label display an incorrect expiration date, extends the shelf life of the product. Affected product distributed in the United States from 3/25/2018 to 9/28/2020, expiration dates between 2022-11-01 and 2025-09-01 (Devices have a lot number ending in R, or are kits containing at least 1 device with a lot number ending in R.)

  • 2015-07-01TerminatedUnder Investigation by firm

    Velocity" Biopsy Valve, 25 units per box, Product Usage: The disposable Velocity biopsy valve is used to cover the opening of the biopsy inlet port of a flexible gastrointestinal endoscope. The Velocity biopsy valve provides access for endoscopic device passage and exchange, helps maintain insufflation, and minimizes leakage of biomaterial from the accessory port throughout the gastrointestinal endoscopic procedure. The Velocity biopsy valve provides a connection for irrigation through the Velocity irrigation pump.

    The company has received reports of structural non conformance at the connection between the valve body and the irrigation tube, resulting in separation of the components during use.

  • 2015-01-26TerminatedPackage design/selection

    Product Code 2C4013, Four Lead TUR Irrigation Set, for use with UROMATIC Plastic Containers, Approximate Length 85" (2.2 m)

    Potential for failure of the pouch packaging seal at high altitudes.

  • 2013-04-11TerminatedDevice Design

    Torrent" irrigation tubing. Product Usage: The Torrent irrigation system (tubing and accessories to accommodate various endoscopes and irrigation pumps) is intended to provide irrigation via irrigation fluids, such as sterile water, during gastrointestinal endoscopic procedures when used in conjunction with an irrigation pump or electrosurgical unit.

    The firm was notified by their customers that there was a water leakage from the white tubing connector.

  • TerminatedProcess control

    STOPCON Disposable Valves Set-Single Use Single Use Valves Olympus R (Air-Water-/Suction-/ Biopsy-Valve) DISTRIBUTED BY: KEY SURGICAL 8101 WALLACE ROAD / EDEN PRAIRIE, MN 55344 / USA Product Code: EN10229

    Suction button is reported sticky and/or broken during or after the procedure, may cause prolonged procedure

  • TerminatedProcess control

    STOPCON Disposable Valves Set-Single Use Valves (suction-/air-water-/biopsy-valve/auxiliary water connector) DISTRIBUTED BY: KEY SURGICAL 8101 WALLACE ROAD / EDEN PRAIRIE, MN 55344 / USA Product Code: EN10229.1

    Suction button is reported sticky and/or broken during or after the procedure, may cause prolonged procedure

  • TerminatedProcess control

    STOPCON Disposable Endoscope Valves Set-Single Use Valves Olympus R (Air-Water-/Suction) DISTRIBUTED BY: KEY SURGICAL 8101 WALLACE ROAD / EDEN PRAIRIE, MN 55344 / USA Product Code: EN10229.2

    Suction button is reported sticky and/or broken during or after the procedure, may cause prolonged procedure

Monitor endoscopic irrigation/suction system automatically

DeviceWatch watches FDA adverse events and recalls for the products you care about, summarizes clinical narratives with AI and alerts you when a safety signal emerges.