OADClass 3

Catheter, Percutaneous, Cardiac Ablation, For Treatment Of Atrial Flutter

FDA adverse event reports and recall history for catheter, percutaneous, cardiac ablation, for treatment of atrial flutter (product code OAD), from the public MAUDE corpus and the live FDA recall database.

Total reports
5,984
Deaths
218
Injuries
2,824
Malfunctions
2,910

Reports per year

12
13
14
15
16
17
18
19
20
21
22
23
24
25
26

Source: FDA adverse event reports by year received, 2012–2026. Reporting paused twice in 2026 during FDA reporting-system changes and has since resumed.

Recent recalls

  • 2026-04-24Open, ClassifiedDevice Design

    Medtronic Sphere-9 Catheter, Model Number AFR-00001; catheter, percutaneous, cardiac ablation, for treatment of atrial flutter.

    Ventricular fibrillation (VF) occurred during radiofrequency (RF) therapy with the Medtronic Sphere-9 catheter in patients who have a Biotronik Implantable Cardioverter Defibrillator (ICD) or Biotronik Cardiac Resynchronization Therapy-Defibrillator (CRT-D) implanted. The observation is caused by an interaction between the Sphere-9 catheter current flow and a safety feature built into Biotronik ICDs and CRT Ds. Medtronic recommends physicians use increased caution when using the Sphere-9 catheter for RF ablation therapy in patients implanted with a Biotronik ICD/CRT-D system, and to ensure external defibrillation systems are readily available.

  • 2022-11-02Open, ClassifiedProcess control

    THERMOCOOL SMARTTOUCH SF Bi-Directional Navigation Catheter, REF: D-1348-05-S. Used for catheter-based cardiac electrophysiological mapping (stimulation and recording) and, in conjunction with an RF generator, for cardiac ablation.

    Manufacturing error resulted in potential contamination of Bi-Directional navigation catheter irrigation path with cellulose fibers that can cause 1) Failure of initial flushing inspection, 2) Insufficient irrigation causing catheter tip temperature increase, limiting the ability to deliver ablation, or 3) particles flushed through the catheter irrigation may have thrombogenic/toxic effect.

  • 2018-08-28Open, Classified

    Boston Scientific Maestro 4000 Cardiac Ablation System, Firmware Version 5.14, Model Numbers: M00440000, M0044000D0, M0044000H0,M0044000R0, M0044000Z0,

    Reports of unintended continuation of radiofrequency (RF) energy delivery from the Cardiac ablation system after the foot switch has been released.

  • 2015-03-02TerminatedDevice Design

    IntellaTip MiFi Open-Irrigated radiofrequency Ablation Catheters: Material number: M004EPM96200, Catalog Number: EPM9620: Material number: M004EPM9620K20, Catalog Number: EPM9620K2; Material number : M004EPM9620N40; Catalog number: EPM9620N4. The IntellaTip MiFi Open-Irrigated Ablation Catheter is a 7.5F (2.5 mm) quadrapolar open-irrigated (OI) ablation catheter designed to deliver radiofrequency (RF) energy to the 4.5 mm catheter tip electrode for cardiac ablation The product is not approved for use/sale in the US.

    Reports of formation of char adherent to the proximal part of the distal tip electrodes

  • 2014-06-16TerminatedUse error

    IntellaTip MiFi XP Temperature Ablation Catheter; 8mm x 8F (2.67mm) Standard Curve. The BSC Controller and Accessories are indicated for use in conjunction with standard and high power catheters for cardiac ablation procedures.

    Some units of Intella Tip MiFi XP Temperature Ablation Catheters were not manufactured according to specification.

  • 2014-06-16TerminatedUse error

    IntellaTip MiFi XP Temperature Ablation Catheter; 8mm x 8F (2.67mm); Large Curve. The BSC Controller and Accessories are indicated for use in conjunction with standard and high power catheters for cardiac ablation procedures.

    Some units of Intella Tip MiFi XP Temperature Ablation Catheters were not manufactured according to specification.

  • 2014-06-16TerminatedUse error

    IntellaTip MiFi XP Temperature Ablation Catheter; 8mm x 8F (2.67mm); Asymmetric Curve. The BSC Controller and Accessories are indicated for use in conjunction with standard and high power catheters for cardiac ablation procedures.

    Some units of Intella Tip MiFi XP Temperature Ablation Catheters were not manufactured according to specification.

  • 2014-06-16TerminatedUse error

    IntellaTip MiFi XP Temperature Ablation Catheter; 10m x 8F (2.67mm) Standard Curve. The BSC Controller and Accessories are indicated for use in conjunction with standard and high power catheters for cardiac ablation procedures.

    Some units of Intella Tip MiFi XP Temperature Ablation Catheters were not manufactured according to specification.

  • 2014-06-16TerminatedUse error

    IntellaTip MiFi XP Temperature Ablation Catheter; 10m x 8F (2.67mm) Large Curve. The BSC Controller and Accessories are indicated for use in conjunction with standard and high power catheters for cardiac ablation procedures.

    Some units of Intella Tip MiFi XP Temperature Ablation Catheters were not manufactured according to specification.

  • 2014-06-16TerminatedUse error

    IntellaTip MiFi XP Temperature Ablation Catheter; 10m x 8F (2.67mm) Asymmetric Curve. The BSC Controller and Accessories are indicated for use in conjunction with standard and high power catheters for cardiac ablation procedures.

    Some units of Intella Tip MiFi XP Temperature Ablation Catheters were not manufactured according to specification.

Monitor catheter, percutaneous, cardiac ablation, for treatment of atrial flutter automatically