NCXClass 2

System, Hypothermia, Intravenous, Cooling

FDA adverse event reports and recall history for system, hypothermia, intravenous, cooling (product code NCX), from the public MAUDE/AEMS corpus and the live FDA recall database.

Total reports
4,355
Deaths
44
Injuries
261
Malfunctions
4,041

Reports per year

12
13
14
15
16
17
18
19
20
21
22
23
24
25
26

Source: FDA adverse event reports by year received, 20122026. Reporting paused during the 2026 MAUDE-to-AEMS transition and has since resumed.

Recent recalls

  • 2014-01-27TerminatedNonconforming Material/Component

    InnerCool RTx Endovascular System, Model Numbers: 861470 (120V), 861472 (240V). Product Usage: The InnerCool RTx device is a thermal regulating system intended to induce, maintain and reverse mild hypothermia, to achieve and/or maintain normothermia, and for use in fever reduction. K080908

    Phillips Healthcare initiated this action because the Main Control Board (MCB) may produce an inaccurate low patient temperature reading and low temperature alarm.

  • 2007-02-15TerminatedOther

    Alsius Cool Line Catheter, Model CL-2295A

    Testing by Alsius has identified that 6-10% of catheters from the three affected lots may exhibit a significant reduction in their heat exchange capacity.

  • 2007-02-15TerminatedOther

    Alsius Cool Line Catheter, Model CL-2295AE

    Testing by Alsius has identified that 6-10% of catheters from the three affected lots may exhibit a significant reduction in their heat exchange capacity.

  • 2006-01-10TerminatedOther

    Alsius CoolGard Temperature Regulation System

    Alsius has found that fluid spills or ingress may result in an alarm condition. The potential health risk involved in this state can be the discontinuance of therapy.

  • 2005-08-24TerminatedOther

    Alsius CoolGard 3000 Temperature Regulation System

    Firm wants users to be aware not to leave the units in standby mode for more than an hour in rooms in excess of 75 F due to risk of an alarm mode being generated due to overheating.

  • 2004-11-25TerminatedOther

    Alsius CoolGard 3000 patient temperature regulation system

    Product alarms that there may be a power supply interruption.

  • 2004-07-23TerminatedOther

    Alsius CoolGuard 3000 Temperature Regulation System, Model CoolGuard 3000

    Higher than expected rate of pump alarms occur under specific conditions.

  • TerminatedLabeling design

    Zoll REF: 8700-0782-01 (IC-3893), ICY Intravascular Heat Exchange Catheter Kit, with central venous infusion capabilities (3 lumens) , Femoral vein Insertion Only, Sterile EO, Rx Only, UDI: (01)00849111075237

    Labeling update concerning potential leaks from the catheter or the start-up kit (SUK) tubing

  • TerminatedLabeling design

    Zoll, REF: 8700-0791-01 (IC-4593), Premium Access Kit QUATTRO, Intravascular Heat exchange Catheter Kit (Heparin), with central venous infusion capabilities (3 lumens), Femoral Vein Insertion Only, Sterile EO, Rx only, UDI: (01)008491110 7550 3

    Labeling update concerning potential leaks from the catheter or the start-up kit (SUK) tubing

  • TerminatedLabeling design

    ZOLL, REF: 8700-0781-01 (CL-2295), COOL LINE, Intravascular Heat Exchange Catheter Kit Applause Custom Luer Heparin, STERILE EO, Rx only, UDI: (01)00849111075190

    Labeling update concerning potential leaks from the catheter or the start-up kit (SUK) tubing

Monitor system, hypothermia, intravenous, cooling automatically