MTDClass 2

Catheter, Intracardiac Mapping, High-Density Array

FDA adverse event reports and recall history for catheter, intracardiac mapping, high-density array (product code MTD), from the public MAUDE/AEMS corpus and the live FDA recall database.

Total reports
1,831
Deaths
29
Injuries
529
Malfunctions
1,257

Reports per year

12
13
14
15
16
17
18
19
20
21
22
23
24
25
26

Source: FDA adverse event reports by year received, 20122026. Reporting paused during the 2026 MAUDE-to-AEMS transition and has since resumed.

Recent recalls

  • 2015-08-28TerminatedIncorrect or no expiration date

    FIRMap 60mm Catheter; Size: 60 mm; Length 50.4 inches French Size Diameter: 8.5F (2.84mm) Model number : USAR064060 Sterile, Rx only Cardiovascular: For use in cardiac electrophysiology procedures to assist in the diagnosis of complex arrhythmias that may be difficult to identify using conventional mapping systems alone.

    The expiration date was incorrectly printed on the pouch/box labels of 19 products that were shipped to customer sites. The manufacturing date was accidentally used (copied) for the expiration date.

  • 2014-03-11TerminatedProcess design

    PENTARAY NAV High-Density Mapping Catheter and PENTARAY NAV ECO Catheter, Catalog No. D128201, D128202, D128204, D128205, D128207, D128208, D128210, D128211. The Biosense Webster PENTARAY NAV High-Density Mapping Catheter is indicated for multiple electrode electrophysiological mapping of cardiac structures in the heart, i.e., recording or stimulation only. This catheter is intended to obtain electrograms in the atrial and ventricular regions of the heart.

    Biosense Webster is recalling the PentaRay Nav Catheter because it has the potential to have partial tip separation from the catheter shaft. Biosense Webster is expanding the recall on 5/1/14 to include all lots of the PentaRay Nav Catheter and the PentaRay Nav ECO Catheter because they can lead to an insufficient bond of the distal tip to the catheter shaft.

  • 2005-03-18TerminatedOther

    Constellation Advanced Mapping Catheter, Model numbers 8031, 8038, 8048, 8060, 8075

    The coating on the product's surface can generate debris, which could then move from the heart towards the brain, resulting in Ischemic events.

  • TerminatedOther

    PENTARAY NAV High-Density Mapping Catheter.

    Contraindication language updated in the Instructions For Use (IFU) to indicate that Pentaray Catheters should not be used in patients with prosthetic valves.

  • TerminatedOther

    PENTARAY NAV High-Density Mapping Catheter.

    Contraindication language updated in the Instructions For Use (IFU) to indicate that Pentaray Catheters should not be used in patients with prosthetic valves.

  • TerminatedProcess control

    FIRMap" Catheter, 60mm Basket

    Incorrect product labeling.

  • TerminatedUse error

    Pentaray NAV High-Density Mapping Catheter, Catalog No. D128201, D128202, D128203, D128204, D128205, D128206 The Biosense Webster Pentaray NAV High-Density Mapping Catheter is intended for multiple electrode electrophysiological mapping of cardiac structures in the heart, ie., recording or stimulation only. This catheter is intended to obtain electrograms in the atrial and ventricular regions of the heart. The Pentaray NAV High-Density Mapping Catheter provides location information when used with compatible CARTO 3 EP Navigation Systems.

    Biosense Webster is recalling the Pentaray Catheters to clarify the contraindication language in the Instructions For Use (IFU) and product labeling for this catheter relative to patients with prosthetic valves.

  • TerminatedUse error

    Pentaray NAV High-Density Mapping ECO Catheter, Catalog No. D128207, D128208, D128209, D128210, D128211, D128212 The Biosense Webster Pentaray NAV High-Density Mapping Catheter is intended for multiple electrode electrophysiological mapping of cardiac structures in the heart, ie., recording or stimulation only. This catheter is intended to obtain electrograms in the atrial and ventricular regions of the heart. The Pentaray NAV High-Density Mapping Catheter provides location information when used with compatible CARTO 3 EP Navigation Systems.

    Biosense Webster is recalling the Pentaray Catheters to clarify the contraindication language in the Instructions For Use (IFU) and product labeling for this catheter relative to patients with prosthetic valves.

  • TerminatedError in labeling

    PENTARAY NAV HIGH-DENSITY MAPPING CATHETER ELECTRODE EA 22 Rx only STERILE EO - Product Usage: The Biosense Webster PENTARAY NAV High-Density Mapping Catheter is indicated for multiple electrode electrophysiological mapping of cardiac structures in the heart, i.e., recording or stimulation only. This catheter is intended to obtain electrograms in the atrial and ventricular regions of the heart.

    Mapping Catheter can become entrapped in the cardiac valvular apparatus while the user is attempting to create an electroanatomic map.

Monitor catheter, intracardiac mapping, high-density array automatically