Skip to main content
MQNClass 2

External Mandibular Fixator And/Or Distractor

FDA adverse event reports and recall history for external mandibular fixator and/or distractor (product code MQN), from the public MAUDE corpus and the live FDA recall database.

Total reports
1,420
Deaths
3
Injuries
1,066
Malfunctions
326

Reports per year

12
13
14
15
16
17
18
19
20
21
22
23
24
25
26

Source: FDA adverse event reports by year received, 2012–2026. Reporting paused twice in 2026 during FDA reporting-system changes and has since resumed.

Recent recalls

  • 2015-01-23TerminatedLabeling design

    The Synthes Mandible External Fixator; all lots of part nos.: 04.305.003 04.305.004 04.305.005 04.305.010 04.305.011 04.305.012 03.305.006 04.305.100 04.305.101 04.305.102 04.305.103 04.305.128 04.305.130 04.305.134 04.305.138 04.305.140 04.305.142 03.305.105 03.305.500 03.305.500S Intended to stabilize and provide treatment for fractures of the maxillofacial area, including severe open mandibular fractures, highly comminuted closed fractures, nonunions and delayed unions (especially associated with infection), fractures associated with infections, tumor resections, facial deformity corrections, gunshot wounds, pan facial fractures, burn maintenance, and bone grafting defects.

    Under new testing protocols for MR Environment safety and compatibility, metal devices are no longer designated MR Safe. Some components in the CMF Mandible External Fixator Systems were labeled and/or etched with information indicating they are MR Safe. They can no longer be labeled MR Safe.

  • 2014-08-20TerminatedDevice Design

    DePuy Synthes Craniomaxillofacial Distraction System (AB Distractor Bodies and BC Distractor Bodies)

    DePuy Synthes is initiating a recall of certain lots of the Craniomaxillofacial Distraction System (AB Distractor Bodies and BC Distractor Bodies) because they may reverse post-operatively.

  • 2013-07-12TerminatedNonconforming Material/Component

    Synthes CMF Distraction System The product is intended for use as a bone stabilizer and lengthening (and/or transport) device for correction of congenital deficiencies or post-traumatic defects of the mandibular body and ramus, where gradual bone distraction is required. It is intended for single use only.

    The firm initiated a voluntary recall of the BC Distractor Body which is part of the Craniomaxillofacial (CMF) Distractor System, due to a mis-alignment issue. There have been instances reported within the impacted lots in which the slot in the barrel of the BC distractor was rotated such that it was not possible to attach the B-type and C-type foot plates.

  • TerminatedUnder Investigation by firm

    TI Single Vector Distractor Body with Right Foot/20mm; Catalog ID 487.962 The Titanium Single Vector Distractor and Proximal Foot Plates are intended for mandibular bone lengthening where gradual bone distraction is required, including conditions such as congenital mandibular deficiencies or post-traumatic defects.

    DePuy Synthes is voluntarily initiating a recall due to a possibility the fastener on the Titanium Single Vector Distractor Body may become prematurely separated from the Proximal Foot Plate.

  • TerminatedUnder Investigation by firm

    TI Single Vector Distractor Body with Left Foot/20mm; Catalog ID 487.963 The Titanium Single Vector Distractor and Proximal Foot Plates are intended for mandibular bone lengthening where gradual bone distraction is required, including conditions such as congenital mandibular deficiencies or post-traumatic defects.

    DePuy Synthes is voluntarily initiating a recall due to a possibility the fastener on the Titanium Single Vector Distractor Body may become prematurely separated from the Proximal Foot Plate.

  • TerminatedUnder Investigation by firm

    TI Single Vector Distractor Body with Right Foot/30mm; Catalog ID 487.964 The Titanium Single Vector Distractor and Proximal Foot Plates are intended for mandibular bone lengthening where gradual bone distraction is required, including conditions such as congenital mandibular deficiencies or post-traumatic defects.

    DePuy Synthes is voluntarily initiating a recall due to a possibility the fastener on the Titanium Single Vector Distractor Body may become prematurely separated from the Proximal Foot Plate.

  • TerminatedUnder Investigation by firm

    TI Single Vector Distractor Body with Left Foot/30mm; Catalog ID 487.965 The Titanium Single Vector Distractor and Proximal Foot Plates are intended for mandibular bone lengthening where gradual bone distraction is required, including conditions such as congenital mandibular deficiencies or post-traumatic defects.

    DePuy Synthes is voluntarily initiating a recall due to a possibility the fastener on the Titanium Single Vector Distractor Body may become prematurely separated from the Proximal Foot Plate.

  • TerminatedUnder Investigation by firm

    TI Single Vector Distractor Proximal Foot/Right; Catalog ID 487.974 The Titanium Single Vector Distractor and Proximal Foot Plates are intended for mandibular bone lengthening where gradual bone distraction is required, including conditions such as congenital mandibular deficiencies or post-traumatic defects.

    DePuy Synthes is voluntarily initiating a recall due to a possibility the fastener on the Titanium Single Vector Distractor Body may become prematurely separated from the Proximal Foot Plate.

  • TerminatedUnder Investigation by firm

    TI Single Vector Distractor Proximal Foot/Left; Catalog ID 487.975 The Titanium Single Vector Distractor and Proximal Foot Plates are intended for mandibular bone lengthening where gradual bone distraction is required, including conditions such as congenital mandibular deficiencies or post-traumatic defects.

    DePuy Synthes is voluntarily initiating a recall due to a possibility the fastener on the Titanium Single Vector Distractor Body may become prematurely separated from the Proximal Foot Plate.

Monitor external mandibular fixator and/or distractor automatically

DeviceWatch watches FDA adverse events and recalls for the products you care about, summarizes clinical narratives with AI and alerts you when a safety signal emerges.