Skip to main content
MPBClass 2

Catheter, Hemodialysis, Non-Implanted

FDA adverse event reports and recall history for catheter, hemodialysis, non-implanted (product code MPB), from the public MAUDE corpus and the live FDA recall database.

Total reports
3,225
Deaths
73
Injuries
607
Malfunctions
2,447

Reports per year

12
13
14
15
16
17
18
19
20
21
22
23
24
25
26

Source: FDA adverse event reports by year received, 2012–2026. Reporting paused twice in 2026 during FDA reporting-system changes and has since resumed.

Recent recalls

  • 2026-09-11Open, ClassifiedMaterial/Component Contamination

    Power-Trialysis Short-Term Straight Dialysis Catheter, REF: 5605150; Power-Trialysis Short-Term Straight Dialysis Catheter, REF: 5605200; Power-Trialysis Short-Term Straight Dialysis Catheter, REF: 5605240; Power-Trialysis Short-Term Straight Dialysis Catheter, REF: 5605300; Power-Trialysis Short-Term Curved Extension Dialysis Catheter, REF: 5615120; Power-Trialysis Short-Term Curved Extension Dialysis Catheter, REF: 5615150; Power-Trialysis Short-Term Curved Extension Dialysis Catheter, REF: 5615200; Power-Trialysis Short-Term Curved Extension Dialysis Catheter, REF: 5615240; Power-Trialysis Short-Term Alphacurve Dialysis Catheter, REF: 5655120; Power-Trialysis Short-Term Alphacurve Dialysis Catheter, REF: 5655150; Power-Trialysis Short-Term Alphacurve Dialysis Catheter, REF: 5655200; Power-Trialysis Short-Term Alphacurve Dialysis Catheter, REF: 5655240; Power-Trialysis Short-Term Straight Dialysis Catheter Full Procedure Tray, REF: 5605200G; Power-Trialysis Slim-Cath Straight Short-Term Dialysis Catheter, REF: 5855200G; Power-Trialysis Slim-Cath Precurved Extension Short-Term Dialysis Catheter, REF: 5865150G; Power-Trialysis Slim-Cath Straight Short-Term Dialysis Catheter, REF: 5855150; Power-Trialysis Slim-Cath Straight Short-Term Dialysis Catheter, REF: 5855200; Power-Trialysis Slim-Cath Straight Short-Term Dialysis Catheter, REF: 5855240; Power-Trialysis Slim-Cath Straight Short-Term Dialysis Catheter, REF: 5855300; Power-Trialysis Slim-Cath Precurved Extension Short-Term Dialysis Catheter, REF: 5865120; Power-Trialysis Slim-Cath Precurved Extension Short-Term Dialysis Catheter, REF: 5865150; Power-Trialysis Slim-Cath Precurved Extension Short-Term Dialysis Catheter, REF: 5865200; Power-Trialysis Slim-Cath Precurved Extension Short-Term Dialysis Catheter, REF: 5865240

    this is a downstream recall of class I recall RES 98777

  • 2026-09-11Open, ClassifiedMaterial/Component Contamination

    DuoGlide Short-Term Straight Dialysis Catheter, REF: 5625150; DuoGlide Short-Term Straight Dialysis Catheter, REF: 5625200; DuoGlide Short-Term Straight Dialysis Catheter, REF: 5625240; DuoGlide Short-Term Straight Dialysis Catheter, REF: 5625300; DuoGlide Short-Term Curved Extension Dialysis Catheter, REF: 5626120; DuoGlide Short-Term Curved Extension Dialysis Catheter, REF: 5626150; DuoGlide Short-Term Curved Extension Dialysis Catheter, REF: 5626200; DuoGlide Short-Term Curved Extension Dialysis Catheter, REF: 5626240; Niagara Dual-Lumen Short-Term Curved Extension Dialysis Catheter, REF: 5766200

    this is a downstream recall of class I recall RES 98777

  • 2026-06-13Open, ClassifiedNonconforming Material/Component

    Description/REF: HEMODIALYSIS KIT: 2-LUMEN 8 FR X 11 CM/AK-11802-F; HEMODIALYSIS KIT: 2-LUMEN 12 FR X 16 CM/AK-22122; HEMODIALYSIS KIT 2L: 14 FR X 15CM AGB/AK-22142-CDC; HEMODIALYSIS KIT 2L: 14 FR X 20CM AGB/AK-25142-CDC; HEMODIALYSIS KIT: 2L 14 FR X 15 CM/ASK-22142-UMD; HEMODIALYSIS KIT: 2L 14 FR X 15 CM/ASK-22142-UNC; HEMODIALYSIS KIT: 2L 14 FR X 20 CM/ASK-25142-UMD; HEMODIALYSIS KIT 2L: 14 FR X 20 CM AGB/ASK-25142-UN1; HEMODIALYSIS KIT: 2L 14 FR X 25 CM/ASK-26142-UMD; HEMODIALYSIS KIT: 2LUMEN 12 FR X 13 CM/AU-23122-F; HEMODIALYSIS KIT: 2LUMEN 12 FR X 20 CM/AU-25122-F; HEMODIALYSIS KIT: 2L 12 FR X 16 CM AGB/CDC-22122-X1A; HEMODIALYSIS KIT: 2L 12 FR X 16 CM AGB/CDC-22122-XU1A; HEMODIALYSIS KIT: 2L 14 FR X 15 CM AGB/CDC-22142-X1A; HEMODIALYSIS KIT: 2L 12 FR X 25 CM AGB/CDC-26122-X1A; HEMODIALYSIS KIT 2L: 12 FR X 16CM AGB/AK-22122-CDC; HEMODIALYSIS KIT: 2-LUMEN 12 FR X 16 CM/AK-22122-F; HEMODIALYSIS KIT: 2-LUMEN 14 FR X 15 CM/AK-22142-F; AHDC AGB U-BEND KIT: 2-L 12 FR X 16 CM/CDC-22122-CN1AU; AHDC AGB CURVED KIT: 2-L 14 FR X 15 CM/CDC-22142-CN1AC; AHDC AGB U-BEND KIT: 2-L 12 FR X 13 CM/CDC-23122-CN1AU; AHDC AGB U-BEND KIT: 2-L 12 FR X 20 CM/CDC-25122-CN1AU; AHDC AGB CURVED KIT: 2-L 14 FR X 20 CM/CDC-25142-CN1AC;

    Lidocaine, Bupivacaine, and 0.9% sodium chloride, the subject of a supplier recall, were included into kits and sets. The supplier was found to have quality issues and limited reports of drug ineffectiveness, and if sterility of a water-based injectable product is compromised this could lead to serious or life-threatening injuries.

  • 2026-06-05Open, ClassifiedUnder Investigation by firm

    Mahurkar Elite PASS Trays; Description (Product Number/CFN): 12 FR x 13cm Acute Dual Lumen Catheter with Straight Extensions, PASS Tray (8888221413), 12 FR x 16cm Acute Dual Lumen Catheter with Curved Extensions, PASS Tray (8888222416), 12 FR x 16cm Acute Dual Lumen Catheter with Straight Extensions, PASS Tray (8888221416), 12 FR x 20cm Acute Dual Lumen Catheter with Curved Extensions, PASS Tray (8888222420), 12 FR x 20cm Acute Dual Lumen Catheter with Straight Extensions, PASS Tray (8888221420), 12 FR x 24cm Acute Dual Lumen Catheter with Curved Extensions, PASS Tray (8888222424), 12 FR x 24cm Acute Dual Lumen Catheter with Straight Extensions, PASS Tray (8888221424), 12 FR x 30cm Acute Dual Lumen Catheter with Straight Extensions, PASS Tray (8888221430), 12.5 FR x 13 cm Acute Triple Lumen Catheter with Curved Extensions, PASS Tray (8888233413), 12.5 FR x 16 cm Acute Triple Lumen Catheter with Curved Extensions, PASS Tray (8888233416), 12.5 FR x 20 cm Acute Triple Lumen Catheter with Curved Extensions, PASS Tray (8888233420), 12.5 FR x 20 cm Acute Triple Lumen Catheter with Straight Extensions, PASS Tray (8888231420), 12.5 FR x 24 cm Acute Triple Lumen Catheter with Curved Extensions, PASS Tray (8888233424), 12.5 FR x 24 cm, Acute Triple Lumen Catheter with Straight Extensions PASS Tray (8888231424), 12.5 FR x 30 cm, Triple Lumen Catheter with Straight Extensions PASS Tray (8888231430), 12.5FR x 13cm Acute Triple Lumen Catheter with Straight Extensions, PASS Tray (8888231413), 12.5FR x 16cm Acute Triple Lumen Catheter with Straight Extensions, PASS Tray (8888231416), 13.5 FR x 16 cm High Flow Acute Dual Lumen Catheter with Curved Cannula, PASS Tray (8888213416), 13.5 Fr x 16cm High Flow Acute Dual Lumen Catheter with Straight Extensions, PASS Tray (8888211416), 13.5 FR x 20 cm High Flow Acute Dual Lumen Catheter with Curved Cannula, PASS Tray (8888213420), 13.5 Fr x 20cm High Flow Acute Dual Lumen Catheter with Straight Extensions, PASS Tray (8888211420), 13.5FR x 13cm High Flow Acute Dual Lumen Catheter with Curved Extensions, PASS Tray (8888212413), 13.5FR x 13cm High Flow Acute Dual Lumen Catheter with Straight Extensions, PASS Tray (8888211413), 13.5FR x 16cm High Flow Acute Dual Lumen Catheter with Curved Extensions, PASS Tray (8888212416), 13.5FR x 20cm High Flow Acute Dual Lumen Catheter with Curved Extensions, PASS Tray (8888212420), 13.5FR x 24cm High Flow Acute Dual Lumen Catheter with Straight Extensions, PASS Tray (8888211424); for acute hemodialysis, aphaeresis, and infusion.

    The Tegaderm CHG dressing, as specified in product labeling, was missing from certain lots of Mahurkar Elite PASS Trays.

  • 2018-02-20TerminatedProcess control

    ARROWg+ard Blue Two Lumen Hemodialysis Catheterization Kit for High Volume Infusions; Product Codes: AK-22142-CDC, AK-22142-F, AK-25142-CDC, AK-25142-F; Exp. Dates Feb 2018 - Nov 2018

    These finished good kits may contain the incorrect Springwire Guide (SWG).

  • 2015-08-18TerminatedLabeling Change Control

    RenLane Renal Denervation Catheter; Cat No.: D135601. Used in adults patients (>18 years) with drug resistant hypertension to denervate the renal arteries to reduce blood pressure.

    Potential Damage may occur to the helical tip of the RENLANE Renal Denervation Catheter, if the hemostasis valve of the arterial access device is not fully open before insertion or withdrawal of the catheter.

  • 2007-09-20TerminatedOther

    Guidewire, 70cm x 1mm, REF 5583705, Sterile, Single Use, BARD Access Systems, Hemodialysis Catheter, Salt Lake City, UT 84116.

    Metal guidewires used in Hemodialysis Catheters may have been reverse loaded within the dispenser. Potential exists for the stiff end of the guidewire to be inserted into the patient instead of the flexible end.

  • 2004-07-20TerminatedOther

    Two Lumen 14F Hemodialysis Catheter Kits/Sets with Blue FlexTip Arrowg+ard Blue Curved Catheter for high Volume Ifusions

    catheter slips out of the suture wing during use.

  • 2003-12-17TerminatedOther

    Mahurkar QPlus Dual Lumen Catheter Kit with Curved Extension, 13.5 Fr/Ch x 19.5cm For hemodialysis, apheresis, and infusion. Reference: 8888-135192

    Product is mislabeled to catheter length. Product labeled as a 13.5 Fr x 19.5 cm may contain a 13.5Fr x 16.0 cm

  • 2003-12-17TerminatedOther

    Mahurkar QPlus Dual Lumen Catheter Insertion Tray with Curved Extension, 13.5 Fr/Ch x 19.5cm For hemodialysis, apheresis, and infusion Reference: 8888-135195

    Product is mislabeled to catheter length. Product labeled as a 13.5 Fr x 19.5 cm may contain a 13.5 Fr x 16.0 cm

Monitor catheter, hemodialysis, non-implanted automatically

DeviceWatch watches FDA adverse events and recalls for the products you care about, summarizes clinical narratives with AI and alerts you when a safety signal emerges.