Skip to main content
MNTClass 2

Continuous, Minimal Ventilatory Support, Facility Use Ventilator

FDA adverse event reports and recall history for continuous, minimal ventilatory support, facility use ventilator (product code MNT), from the public MAUDE corpus and the live FDA recall database.

Total reports
48,851
Deaths
250
Injuries
525
Malfunctions
48,026

Reports per year

12
13
14
15
16
17
18
19
20
21
22
23
24
25
26

Source: FDA adverse event reports by year received, 2012–2026. Reporting paused twice in 2026 during FDA reporting-system changes and has since resumed.

Recent recalls

  • 2025-07-02Open, ClassifiedDevice Design

    BiPAP A40 Ventilator. Used to provide noninvasive ventilation support for the purpose of treating adult and pediatric patients. BiPAP A40 Pro - sold OUS

    This device does not indicate for use in patients with respiratory failure.

  • 2024-05-24Open, ClassifiedDevice Design

    BiPAP A40 Ventilators: BiPAP A40, Part Numbers 1111169 (US and OUS) and (OUS ONLY)1111170 1111171 1111173 1111174 1111175 1111177 1116156 1111170S BR1111169 CN1111169 IT1111169 R1111169 R1111177 R1116156 ; BiPAP A40 Pro, Part Numbers (OUS Only): ARX3100S19 AUX3100S19 BLX3100S19 BRX3100S18 CAX3100S12 CAX3100T12 DEX3100S13 EEX3100S19 ESX3100S19 FRX3100S14 GBX3100H19 GBX3100S19 IAX3100S19 INX3100H19 INX3100S19 ITX3100S21 SPX3100S19 ; BiPAP A40 EFL, Part Numbers (OUS Only): AUX3000S19 DEX2900S13 DEX3000S13 EEX3000S19 ESX3000S19 FRX3000S14 GBX3000S19 INX3000H19 ITX3000S21

    Potential for devices to experience interruption/loss of therapy during a Ventilator Inoperative alarm. This may lead to hypoventilation, mild to severe hypoxemia, hypercarbia, respiratory failure/insufficiency, or potentially death in the most vulnerable patients.

  • 2023-09-28Open, ClassifiedNonconforming Material/Component

    Philips Respironics V60/V60 Plus Ventilator, PCBA Part Number: 453561544461 V60 Device Part Numbers 1053617 (US) and 1137276 (Philippines)

    Power Management PCBAs may malfunction, causing a power failure leading to ventilator loss of function.

  • 2023-06-29Open, ClassifiedNo Marketing Application

    Philips Respironics V60 Ventilator-Intended to mechanically control or assist patient breathing by delivering a predetermined percentage of oxygen in the breathing gas. Model Number: R1053618 and R1076709. These are retrofitted device.

    Devices were imported with Japanese Language and NIST Oxygen Gas Fittings and retrofitted, may pose a serious health risk as the gas pathway of these devices may be contaminated.

  • 2022-04-18Open, ClassifiedDevice Design

    Philips Respironics V60 Ventilator (All Models, including: 1053613, 1053614, 1053615, 1053616, 1053617, 1053618, 1076709, 1076716, 1076717, 1137292, DU1053617, U1053617, R1053618, R1076709)

    Ventilator units have an issue impacting an internal electrical circuit within the ventilators, that in some cases could result in the ventilator ceasing to operate.

  • 2022-04-18Open, ClassifiedDevice Design

    Philips Respironics V60 Plus Ventilator (All Models, including: 1138747, 1137276)

    Ventilator units have an issue impacting an internal electrical circuit within the ventilators, that in some cases could result in the ventilator ceasing to operate.

  • 2022-04-18Open, ClassifiedDevice Design

    Philips Respironics V680 Ventilator (All Models, including: P/N 1103044 (850011)), *Distributed outside the United States

    Ventilator units have an issue impacting an internal electrical circuit within the ventilators, that in some cases could result in the ventilator ceasing to operate.

  • 2022-02-25Open, ClassifiedProcess control

    Philips Respironics V60 Ventilator Part Number 1053617

    A limited number of ventilators were assembled with expired adhesive. If the adhesive fails, a bracket may become loose and potentially damage the capacitors, which could cause the ventilator to stop providing ventilation to the patient. This failure may either activate both visual and audible alarms, or it may not sound or display an alarm (a silent shutdown).

  • 2022-02-25Open, ClassifiedProcess control

    Philips Respironics V60 Plus Ventilator Part Number 1138747

    A limited number of ventilators were assembled with expired adhesive. If the adhesive fails, a bracket may become loose and potentially damage the capacitors, which could cause the ventilator to stop providing ventilation to the patient. This failure may either activate both visual and audible alarms, or it may not sound or display an alarm (a silent shutdown).

  • 2021-01-22Open, ClassifiedDevice Design

    Philips Respironics V60 Ventilator Part Number 1053613 - Product Usage: intended to be used only with various combinations of Respironics-recommended patient circuits, interfaces (masks), humidifiers, and other accessories.

    Potential issues with ventilator navigation ring interface and liquid ingress: 1) The navigation ring may become inoperative or operate intermittently; 2) The navigation ring may cause ventilator parameter values to change erratically during setting entries and adjustments.

Monitor continuous, minimal ventilatory support, facility use ventilator automatically

DeviceWatch watches FDA adverse events and recalls for the products you care about, summarizes clinical narratives with AI and alerts you when a safety signal emerges.