Skip to main content
MNHClass 2

Orthosis, Spondylolisthesis Spinal Fixation

FDA adverse event reports and recall history for orthosis, spondylolisthesis spinal fixation (product code MNH), from the public MAUDE corpus and the live FDA recall database.

Total reports
4,394
Deaths
2
Injuries
2,822
Malfunctions
1,538

Reports per year

12
13
14
15
16
17
18
19
20
21
22
23
24
25
26

Source: FDA adverse event reports by year received, 2012–2026. Reporting paused twice in 2026 during FDA reporting-system changes and has since resumed.

Recent recalls

  • 2017-04-27TerminatedLabeling mix-ups

    5.5mm Diameter x 500mm CoCr Straight Rod, Model number X077-0420. The product is packaged in plastic bags with one piece per bag. Product Usage: The 5.5mm dia. X 500 mm CoCr Straight Rod is an accessory to the Fortex Pedicle Screw System. It is a straight rod connected between two or more pedicle screws to create a pedicle screw construct. Indications for Use: The Fortex Pedicle Screw System is indicated for the treatment of severe spondylolisthesis (Grade 3 and 4) of the L5-S1 vertebra in skeletally mature patients receiving fusion by autogenous bone graft having implants attached to the lumbar and sacral spine (L3 to sacrum) with removal of the implants after the attainment of a solid fusion. In addition, the system is intended to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities of the thoracic, lumbar and sacral spine: degenerative spondylolisthesis with objective evidence of neurological impairment, fracture, dislocation, scoliosis, kyphosis, spinal tumor, and failed previous fusion (pseudarthrosis).

    The material type on the label may incorrectly state Ti6Al-4V ELI. The rods are composed of Cobalt Chromium.

  • 2015-07-10TerminatedDevice Design

    Altiva / Exactech Spine, Large Set Screw, Catalog Number 28202, Lot Number AS05107. Intended to provide immobilization and stabilization of spinal segments.

    Incorrect thread form on the screw.

  • 2015-06-22TerminatedOther

    Fortex" Pedicle Screw System Continuous Radius Rod 5.5 - 50mm, X-Spine Systems, Inc., 452 Alexandersville Road Miamisburg, OH 45342 Phone: 937-847-8400

    The Continuous Radius Rod should measure 50mm in length but actually measures 45mm in length.

  • 2015-04-22TerminatedNonconforming Material/Component

    Xpress System Pedicle Screw Assembly, 5.5 x 55mm. An internal fixation device for spinal surgery consisting of rods, pedicle screw assemblies (screw, cap, yoke) and cross bar connector assemblies.

    One lot of instruments have etched on the Yoke of the Pedicle Screw a laser marking size of 7.5 x 55mm instead of 5.5 x 55mm as described on the product label.

  • 2013-03-11TerminatedEmployee error

    Synthes Spine 5.2mm Titanium Click ' X Pedicle Screw Dual Core 40 mm Thread Length, Part Number 487.072. Intended to provide precise and segmental stabilization of the spine in skeletally mature patients.

    Lot number 7542279, of the 45 mm Click 'X Pedicle Screw (Part number 487.072), was incorrectly etched as "Click 'X Pedicle Screw 05.2 L40 TAN violet" although the actual length of the screw is 45 mm.

  • 2012-10-29TerminatedNonconforming Material/Component

    ILLlCO MIS Posterior Fixation System, Bone-screw Internal Spinal Fixation System, Orthosis, Spinal Pedical Fixation Orthosis, Spondylolisthesis Spinal Fixation The ILLICO MIS Posterior Fixation System is intended to facilitate the surgical correction of noncervical spinal deformities by providing temporary internal fixation and stabilization during bone graft healing and/or fusion mass development. When used for a minimally invasive posterior approach ILLlCO MIS Instrumentation is used in conjunction with polyaxial screw components. The ILLICO MIS Posterior Fixation System is intended for use as a posterior spinal fixation device to aid in the surgical correction of various spinal deformities and pathologies of the spine. It is intended to provide stabilization during the development of fusion utilizing a bone graft. Specific indications for the ILLICO MIS Posterior Fixation System are dependent in part on the configuration of the assembled device and the method of attachment to the spine.

    The firm initiated the recall because the stainless steel guide-wire of the Illico MIS Fixation System did not completely fit/pass through the tip of certain Illico Ti Cannulated Polyaxial Screws, therefore rendering such screws nonfunctional.

  • 2009-09-22TerminatedNonconforming Material/Component

    Fixed Closed Screw, 6.5mm (D) x 40mm (L), Made in USA; Biomet Spine, Parsippany, NJ The screw devices are an internal fixation device intended to aid in the alignment and stabilization of fractures to the skeletal system until healing has occurred. Implants used in this application include non sterile and sterile bone screws.

    Some devices could have been made with raw material lots that may have inclusions, and could result in decreased strength of the device.

  • 2009-09-22TerminatedNonconforming Material/Component

    Fixed Open Screw (TI); 7.0MM (D) x 30MM (L); Made In USA, Biomet Spine, Parsippany, NJ 07054 The screw devices are an internal fixation device intended to aid in the alignment and stabilization of fractures to the skeletal system until healing has occurred. Implants used in this application include non sterile and sterile bone screws.

    Some devices could have been made with raw material lots that may have inclusions, and could result in decreased strength of the device.

  • 2009-09-22TerminatedNonconforming Material/Component

    Fixed Closed Screw (Ti); 5.0MM (D) x 25MM (L); Made in USA, Biomet Spine, Parsippany, NJ 07054 The screw devices are an internal fixation device intended to aid in the alignment and stabilization of fractures to the skeletal system until healing has occurred. Implants used in this application include non sterile and sterile bone screws.

    Some devices could have been made with raw material lots that may have inclusions, and could result in decreased strength of the device.

  • 2009-09-16TerminatedOther

    Stryker Trio Connector Hex Socket for Torque Wrench 3.5MM Not Sterile: Manufactured by: Stryker Spine SAS, Cestas, France; Distributed in the USA by: Stryker Spine, Allendale, NJ 07401 The Trio 3.5MM Hex Socket is a reusable instrument, sterilized prior to use, used with the Trio Torque Wrench to facilitate final tightening of Trio connectors and 3.5MM Hex Screw Assembly. This Trio 3.5MM Hex Socket is used with the Trio implant system for posterior noncervical pedical and non pedical fixation of the spine.

    The Trio 3.5MM Hex socket has been reported to break under high stresses.

Monitor orthosis, spondylolisthesis spinal fixation automatically

DeviceWatch watches FDA adverse events and recalls for the products you care about, summarizes clinical narratives with AI and alerts you when a safety signal emerges.