Skip to main content
MEQClass 3

System, Hyperthermia, Rf/Microwave (Benign Prostatic Hyperplasia),Thermotherapy

FDA adverse event reports and recall history for system, hyperthermia, rf/microwave (benign prostatic hyperplasia),thermotherapy (product code MEQ), from the public MAUDE corpus and the live FDA recall database.

Total reports
1,248
Deaths
7
Injuries
342
Malfunctions
867

Reports per year

02
03
04
05
06
07
08
09
10
11
12
13
14
15
18

Source: FDA adverse event reports by year received, 2002–2018. Reporting paused twice in 2026 during FDA reporting-system changes and has since resumed.

Recent recalls

  • 2011-06-30TerminatedNonconforming Material/Component

    The following kits contain the UROLOGIX, Coolant Bag, CA1111B, Sterile EO, Manufactured for: UROLOGIX, Inc., 14405 Twenty-first Avenue North, Minneapolis, MN 55447. UROLOGIX, CTC Advance Short, (2.5-3.5 cm), PT1034, Sterile EO,Manufactured by: UROLOGIX, Inc., 14405 Twenty-first Avenue North, Minneapolis, MN 55447. CTC Advance Standard , (3.0-5.0 cm), PT1036, Sterile EO,, Manufactured by: UROLOGIX, Inc., 14405 Twenty-first Avenue North, Minneapolis, MN 55447. CTC Advance Long, (4.5+ cm), PT1038, Sterile EO,Manufactured by: UROLOGIX, Inc., 14405 Twenty-first Avenue North, Minneapolis, MN 55447. Targis Standard, (3.0-5.0 cm), PT1013, Sterile EO,Manufactured by: UROLOGIX, Inc., 14405 Twenty-first Avenue North, Minneapolis, MN 55447. The Urologix Targis system is a non-surgical device intended to relieve symptoms and obstruction associated with Benign Prostatic Hyperplasia (BPH) and is indicated for men with prostatic urethral lengths greater than 2.5 cm.

    Urologix is recalling certain lots of Targis System Coolant Bag devices distributed over a two week period. The devices are packaged into disposable Procedure Kits containing a microwave catheter, a Coolant Bag and a RTU Plus balloon. The reason for this Recall involves three lots of Coolant Bags that contain an increased risk of leakage of water at the Sensor Module. This leak is detectabl

  • 2010-03-19TerminatedIncorrect or no expiration date

    UROLOGIX CTC Advance" Standard Microwave Catheter (3.0-5.0 cm), CTC Advance" Long Microwave Catheter (4.5+ cm), CTC Advance" Short Microwave Catheter (2.5 -3.5 cm), RTU Plus Balloon, and RTU Plus Handle, Sterile EO, Manufactured by UROLOGIX, INC, 14405 Twenty-First Avenue North, Minneapolis, MN 55447. The CTC Advance" catheters and RTU Plus are used as part of the Targis System. Each disposable device is packaged on a card inside a heat sealed pouch. Each Kit Box then hold 3 product pouches: 1 catheter, 1 coolant bag and 1 RTU Plus balloon. The RTU Plus Kit contains 3 RTU Plus Handles packaged in separate sterile pouches.

    Urolgix is recalling certain lots of CTC Advance" catheters and RTU Plus devices which are integral components of the Targis System. The reason for this Recall is a labeling error only; the issue involves a discrepancy in the"Use Before" date printed on the product label. In the affected lots, the "Use Before" date , commonly known as the expiration date, is printed as 2012-12 when it should r

  • 2009-07-28TerminatedProcess design

    Prolieve Thermodilatation Catheter Kit, a Transurethral Microwave Therapy (TUMT) System, for BPH (Benign Prostatic Hyperplasia) Thermotherapy, Material Numbers M0068808022 and M0068808170.

    Balloon leaks: Boston Scientific has received complaints from the field involving product leaks associated with the anchor balloons and compression balloons. Correspondence between BSC and FDA has led to BSC's decision to remove the Prolieve Catheter Kits from the field.

  • 2007-04-05TerminatedOther

    Urologix Microwave Delivery System 3.0 - 5.0. For use with prostatic urethra lengths of 3.0-5.0 cm only. Model TA1121D.

    The catheter in the kit matches the description on the kit and pouch label; however, an incorrect label was placed onto the catheter during manufacturing.

  • 2007-04-05TerminatedOther

    Urologix Microwave Delivery System 2.5 - 3.5 For use with prostatic urethra lengths of 2.5-3.5 cm only. Model TA1321D.

    The catheter in the kit matches the description on the kit and pouch label; however, an incorrect label was placed onto the catheter during manufacturing.

  • 2006-07-19TerminatedOther

    Prolieve Thermodilatation Kit, consisting of a Prolieve Thermodilatation Catheter, Prolieve Heat Exchanger cartridge and 500 ml bag of sterile water, Catalog # 880-8023, packaged in single packs, Material Number M0068808022, and five packs, Material Number M0068808023, labeled in part *** Distributed by Boston Scientific Corporation, Natck, MA***Manufacturer: Celsion Corporation, Columbia, MD***.

    A medical device accessory used by healthcare practitioners in the invasive treatment of (BPH) benign prostatic hyperplasia may be defective. The catheter may fail to achieve or maintain recommended pressure.

  • 2006-05-06TerminatedOther

    Prolieve Thermodilatation Kit, consisting of a Prolieve Thermodilatation Catheter, Prolieve Heat Exchanger cartridge and 500 ml bag of sterile water, Catalog # 880-8023, Material Number M0068808023, labeled in part *** Distributed by Boston Scientific Corporation, Natck, MA***Manufacturer: Celsion Corporation, Columbia, MD***.

    Surgical treatment kits containing medical device components were mislabeled with extended expiration dates.

  • 2004-08-11TerminatedOther

    Prolieve Thermodilatation System, model number M0068808000, labeled in part***Distributed by Boston Scientific Corporation, Natick, MA Manufactured by Celsion Corporation, Columbia, MD 21046***

    Software controlling a medical device for patient treatment may malfunction and cause thermal injury to patient.

  • 2004-07-20TerminatedOther

    Prostatron Praktis Type II for Transurethral Microwave Thermotherapy. The Prostatron is a computer-controlled device designed to deliver microwave energy to the prostrate for the treatment of BPH (Benign Prostatic Hyperplasia). The Prostatron utilizes a transurethral microwave antenna, with simultaneous urethral cooling, to heat the prostate. This heating process is regulated through feedback from a series of temperature sensors.

    During treatments, using the Prostatron units, the devices' Temperature Sensing System may change the rectal temperature reading by up to 2 degrees Celsius and may briefly delay updates to the rectal temperature reading.

Monitor system, hyperthermia, rf/microwave (benign prostatic hyperplasia),thermotherapy automatically