Skip to main content
LZPClass 3

Aid, Surgical, Viscoelastic

FDA adverse event reports and recall history for aid, surgical, viscoelastic (product code LZP), from the public MAUDE corpus and the live FDA recall database.

Total reports
2,964
Deaths
1
Injuries
2,010
Malfunctions
900

Reports per year

12
13
14
15
16
17
18
19
20
21
22
23
24
25
26

Source: FDA adverse event reports by year received, 2012–2026. Reporting paused twice in 2026 during FDA reporting-system changes and has since resumed.

Recent recalls

  • 2026-08-31Open, ClassifiedDevice Design

    HEALON EndoCoat PRO, REF: 10300012 (US/CAN) HEALON DUET PRO II, REF: 10300016 (US/CAN) HEALON EndoCoat PRO, REF: 10301012 (EU); HEALON DUET PRO II, REF: 10301016 (EU)

    Surgical instructions sent for viscoelastic products used during ophthalmic viscosurgical cataract procedures including in part: If resistance is encountered during insertion, withdraw cannula and reassess the insertion conditions (i.e. insertion angle, incision size, etc.) before proceeding because forcing the cannula may cause corneal abrasion, iris trauma or descemet's membrane detachment.

  • 2020-01-27TerminatedLabeling False and Misleading

    Healon GV PRO 0.85 mL, Model (U.S.): 10-2400-14, Model (O.U.S.): 10-2705-14, 10-2715-14, 10-2725-14, and 10-2755-14

    Ophthalmic viscosurgical device may be difficult to remove from the eye, leading to increased postoperative intraocular pressure requiring additional intervention. Also, reports of clogging of phacoemulsion equipment tubing, which may lead to delay in the procedure or ocular injury.

  • 2014-12-12TerminatedUnknown/Undetermined by firm

    Abbott Healon EndoCoat Ophthalmic Viscosurgical Device 3% sodium hyaluronate 0.85 mL 30 mg/mL Sterile A Solution Sterile EO Packaging and Cannula Product of USA Abbott Healon Duet Dual Pack 0.55 ml OVD 0.85 ml Healon EndoCoat OVD Contents: -one sterile syringe of Healon Ophthalmic Viscosurgical Device (OVD) 0.55 ml (10 mg/ml Sodium Hyaluronate) -one sterile syringe of Healon EndoCoat Ophthalmic Viscosurgical Device (OVD) 0.85 ml (30 mg/ml Sodium Hyaluronate) Part Number: US: VT585U and 57502000 (packaged in Healon Duet 10290080) OUS: VT585 and 57550500 (packaged in Healon duet 10220010, 10220011 and 10220012)

    AMO has received complaints where the finger grip dislodged while depressing the syringe plunger. The finger grip dislodgement could result in the surgeon's hand unintentionally moving the cannula further than intended, resulting in potential trauma to the eye.

  • 2013-12-20TerminatedNo Marketing Application

    Viscocel and Viscocel Plus. These products are intraocular fluid devices consisting of non-gaseous fluid intended to be introduced into the eye to aid performance of surgery, such as to maintain anterior chamber depth, preserve tissue integrity, protect tissue from surgical trauma, or function as a tamponade during retinal reattachment.

    CLR Medicals International Inc., initiated a nationwide recall of Viscocel and Viscocel Plus, in response to FDA inspection findings of deficiencies in the Quality System Regulations for Medical Device Manufacturers, 21 Code of Federal Regulation (CFR) Part 820 and lack of Premarket Approval (PMA) for devices sold or distributed in domestic commerce. The Viscoelastic products, intended for human

  • 2010-12-16TerminatedComponent design/selection

    Beaver-Visitec International (Beaver-Visitec) BD 1% OVD Sodium Hyaluronate, 10 mg/ml 1.0 mL. Sterile. Rx For Intraocular Use REF 585304 Use as a surgical aid to protect corneal endothelium during cataract extraction procedures, intraocular lens implantation and anterior segment surgery.

    Finger flange on the BD 1% OVD syringe can disengage during cataract surgery and and may lead to injury.

  • 2008-12-10TerminatedProcess design

    AMO Healon D Ophthalmic Viscosurgical Device, Product Code: 10204011, Lot Number: UD30654, 30 mg/mL fill size

    Endotoxin levels above specifications have been noted in some syringes tested for lot number UD30654 of the AMO Healon D Ophthalmic Viscosurgical Device. Endotoxin levels above the maximum USP level may be potential causes of an inflammatory response and/or TASS in patients following surgery.

  • 2005-08-23TerminatedOther

    Staarvisc II Sodium Hyaluronate 0.8 mL 12mg/mL Syringe. Sterile. Rx. For intraocular use. P/N490-001 Distributed by: STAAR Surgical Inc., Monrovia CA

    Product sterility may be compromised due incomplete heat seals in the cannula pouches that are included with the viscoelastic syringe.

  • 2005-08-23TerminatedOther

    ShellGell Sodium Hyaluronate 0.8mL Syringe, 12 mg/mL. Sterile. Rx. For intraocular use. Product Number: 1000 Distributed by Cytosol Opthalmics, Inc., Lenick, NC

    Product sterility may be compromised due incomplete heat seals in the cannula pouches that are included with the viscoelastic syringe.

  • 2005-08-23TerminatedOther

    Amvisc Sodium Hyaluronate 0.5 mL. Bausch & Lomb, Inc., Rochester, NY Product Number: 59051

    Product sterility may be compromised due incomplete heat seals in the cannula pouches that are included with the viscoelastic syringe.

  • 2005-08-23TerminatedOther

    Amvisc Sodium Hyaluronate 0.8 mL. Bausch & Lomb, Inc., Rochester, NY Product Numbr: 59081

    Product sterility may be compromised due incomplete heat seals in the cannula pouches that are included with the viscoelastic syringe.

Monitor aid, surgical, viscoelastic automatically

DeviceWatch watches FDA adverse events and recalls for the products you care about, summarizes clinical narratives with AI and alerts you when a safety signal emerges.