LXGClass 1

Equipment, Laboratory, General Purpose, Labeled Or Promoted For A Specific Medical Use

FDA adverse event reports and recall history for equipment, laboratory, general purpose, labeled or promoted for a specific medical use (product code LXG), from the public MAUDE/AEMS corpus and the live FDA recall database.

Total reports
1,540
Deaths
2
Injuries
29
Malfunctions
1,471

Reports per year

12
13
14
15
16
17
18
19
20
21
22
23
24
25
26

Source: FDA adverse event reports by year received, 20122026. Reporting paused during the 2026 MAUDE-to-AEMS transition and has since resumed.

Recent recalls

  • 2026-01-21Open, ClassifiedSoftware design

    TS-10/TS-10H Tube Sorter, automatic sorting system for sorting barcoded sample tubes, Catalog Number BN168792, running software versions 00-17

    Under specific conditions, the lift's electromagnetic holding force may disengage unexpectedly, allowing unintended downward movement of the lift.

  • 2025-08-22Open, ClassifiedLabeling Change Control

    Dynex Agility Sample Tips; Model Number: 67910; The 67910 Agility Sample Tips are an accessory/consumable used with the Agility Automated ELISA system.

    The internal label affixed to the sample tip rack is incorrectly labeled as reagent tip racks. When scanned by the Agility instrument, the tip rack is misidentified as a different tip type, rendering it incompatible with the system and preventing use which causes a delay in obtaining patient results.

  • 2023-06-16Open, ClassifiedProcess design

    Serrated Blade Applicator Kit (12 Sample), REF: 552687, For use with the Spife Nexus system, Contents: 30 Blade Applicators. used in invitro diagnostics

    Packaging for a serrated blade applicator kit (12 Sample) may contain a serrated blade applicator (18 sample). This results in a characteristic pattern of missed or light samples on the gel, leading to incorrect or no result, or delay in result.

  • 2016-08-25TerminatedNonconforming Material/Component

    Hydroflex ELISA The HYDROFLEX is a plate washer for 96-well microplates. The instrument is intended to be used primarily in in-vitro diagnostic processing of samples from the human body to obtain information on physiological and pathological states. Software and instrument have been validated for processing of qualitative and quantitative Enzyme-linked Immunosorbent Assays (ELISA) and therefore are intended for professional use in in-vitro diagnostics. The instrument has not been validated for other areas of application not mentioned in the Intended Use (e.g. veterinary, biopharma).

    The batteries have the potential to overheating, melt or char.

  • 2014-06-19TerminatedDevice Design

    VersaCell X3 Solution and VersaCell X3 Expansion Pack, a robotic laboratory sample-management system. It connects up to 3 instruments and provides a user interface that routes samples, reduces manual tasks and consolidates results.

    The keyboard and monitor may not be properly secured to the monitor arm.

  • 2012-10-09TerminatedLabeling design

    PREVI Isola System, Catalog numbers 29500 and 29500R, bioMerieux, Inc., Durham, NC. Intended to perform the inoculation and streaking of Prepoured Media (PPM) with liquid microbiological samples.

    The instrument may not dispense the specimen onto the pre-poured media resulting in a false negative result.

  • 2011-08-29TerminatedOther

    MagNA Pure LC 1.0 (software version 3.0.11). Roche Diagnostics Operations, Inc. An automated instrument used for isolation of nucleic acids (DNA, total RNA, total viral nucleic acids) from different kinds of biological research sample material (whole blood, serum, blood cells, culture cells, tissue, bacteria, fungi) using the specially designed MagNA Pure LC kits, for the purpose of life science research only and automated filling of different kinds of PCR reaction vessels (LightCycler Capillaries, 96-well PCR plates, PCR tube strips) with PCR reaction mixes and template nucleic acid, or other reaction tubes for the making of dilution series, reaction mixes.

    Roche has detected a problem with the MagNA Pure LC 1.0 (software version 3.0.11) and the MagNA Pure LC 2.0 (software versions 1.1.23 and 1.1.24) instruments. Under certain circumstances, only a fraction of each sample is processed which may lead to false negative results, and an impact to patient health if used in a homebrew diagnostic application.

  • 2011-08-29TerminatedOther

    MagNA Pure LC 2.0 (software version 1.1.23 and 1.1.24) Roche Diagnostics Operations, Inc. An automated instrument used for isolation of nucleic acids (DNA, total RNA, total viral nucleic acids) from different kinds of biological research sample material (whole blood, serum, blood cells, culture cells, tissue, bacteria, fungi) using the specially designed MagNA Pure LC kits, for the purpose of life science research only and automated filling of different kinds of PCR reaction vessels (LightCycler Capillaries, 96-well PCR plates, PCR tube strips) with PCR reaction mixes and template nucleic acid, or other reaction tubes for the making of dilution series, reaction mixes.

    Roche has detected a problem with the MagNA Pure LC 1.0 (software version 3.0.11) and the MagNA Pure LC 2.0 (software versions 1.1.23 and 1.1.24) instruments. Under certain circumstances, only a fraction of each sample is processed which may lead to false negative results, and an impact to patient health if used in a homebrew diagnostic application.

  • 2011-05-19TerminatedOther

    AutoMate TM Sample Processing System, P/N A20745 Basic Assembly - Automate The AutoMate system prepares sample tubes for diagnostic testing and for storage. The AutoMate system contains an automated track that connects to Input/Output, Centrifuge, Serum Level Detection, Decapper, and Output modules. The AutoMate TM 800 model also contains and Aliquot module.

    The recall was initiated because Beckman Coulter has confirmed an issue with the AutoMate Sample Processing Systems. If during the recovery from Error 81201001, a stuck sample carrier with a tube is moved backwards to the loading position, sample tube/input tray information will become mismatched for samples being loaded onto the AutoMate.

  • 2009-05-18TerminatedDevice Design

    Roche MagNA Pure LC Workstation; Product Numbers: 12236931001, 12236931444, 12236931692 and 03670325001. Robotic workstation for automated isolation of nucleic acids from different kinds of crude sample material such as whole blood, serum, blood cells, culture cells, tissue, bacteria and fungi.

    Protruding screw threads may cut the user when cleaning the interior of the instrument.