Recent recalls
- 2026-09-14Open, ClassifiedNonconforming Material/Component
Medline Convenience Kits: 1) DYKM1000B, Catalog Number: DYKM1000B; 2) DYKM2187A, Catalog Number: DYKM2187A
The kits contain certain lots of sterile applicators which may contain fungal contamination that may occur under certain environmental conditions, allowing the growth of Aspergillus penicillioides. Contamination of skin preparation products with Aspergillus penicillioides may lead to serious adverse health consequences, including systemic infection, sepsis, illness, and death.
- 2026-08-31Open, ClassifiedNonconforming Material/Component
Medline Convenience Kits: 1) IV START KIT LAB DRAW-SH, Model Number: CDS860014P; 2) IV START KIT, Model Number: DYKM1000B; 3) KIT, I V START NSK, Model Number: DYKM2187; 4) KIT, I V START NSK, Model Number: DYKM2187A; 5) IV BLOOD CULTURE KIT, Model Number: DYNDH1909A; 6) IV START W/EXT SET KIT, Model Number: DYNDV1615I
The kits contain BD ChloraPrep Clear - 1 mL and FREPP Clear 1.5 mL Applicators which have a potential breach of sterility in the packaging, due to wrinkles in the paper lidding which may extend to the seal area. If the sterile barrier is compromised, patients and users may be exposed to microbial contamination. Potential health consequences may include no injury, localized infection, or, less commonly, more serious infection requiring medical treatment, antimicrobial therapy, procedural intervention, or hospitalization. In rare cases, particularly in critically ill or immunocompromised patients, severe infection could become life-threatening.
- 2026-08-31Open, ClassifiedNonconforming Material/Component
Medline Convenience Kits containing BD ChloraPrep Clear - 1mL Applicators IV START KIT LAB DRAW-SH CDS860014Q IV START KIT DYKM1000B IV START KIT LAB DRAW-SH CDS860014P ULTRASOUND GUIDED PIV START KI DYNDV2684
Downstream recall - manufacturer recalled specific lots of BD ChloraPrep Clear - 1mL Applicators. Affected product may exhibit an open or incomplete seal on the packaging of the applicator. Use of potentially contaminated applicator may lead to localized skin or soft tissue infection, or systemic infection or infectious complications.
- 2026-06-29Open, ClassifiedNonconforming Material/Component
Medline Convenience Kits: 1) ARTERIAL LINE KIT, Model Number: ART890B; 2) ULTRASOUND GUIDED IV SECUREMENT SET, Model Number: IVS3350
The kits containing Huons Lidocaine HCL Injection USP 1% 10mg/ml 5mL Ampules (Lidocaine Ampules)(OEM). A recall notice was issued by Huons Co., Ltd. for Lidocaine Ampules due to quality issues identified during a recent FDA manufacturing inspection of its drug manufacturing site.
- 2026-06-13Open, ClassifiedNonconforming Material/Component
Description/REF: PI CVC KIT: 3L 7 FR X 16 CM AGB+/ASK-42703-PNHS2; PI CVC KIT: 3L 7 FR X 20 CM AGB+/ASK-45703-PNHS2; PI CVC KIT: 4L 8.5 FR X 20 CM AGB+/ASK-45854-PNHS2
Lidocaine, Bupivacaine, and 0.9% sodium chloride, the subject of a supplier recall, were included into kits and sets. The supplier was found to have quality issues and limited reports of drug ineffectiveness, and if sterility of a water-based injectable product is compromised this could lead to serious or life-threatening injuries.
- 2026-06-13Open, ClassifiedNonconforming Material/Component
Description/REF: CVC/PSI KIT: 2 LUMEN 8 FR X 6 IN/ASK-42802-PLH; CVC KIT: 3-LUMEN 12 FR X 16 CM/AK-12123-F; CVC KIT: 3-LUMEN 12 FR X 20 CM/AK-15123-F; 3L CVC KIT: 7 FR X 16 CM/ASK-12703-PMAH; 3L PI CVC KIT: 7 FR X 16 CM/ASK-12703-PNM; 3L CVC KIT: 7 FR X 16 CM/ASK-12703-PUMH; MULTILUMEN PI CVC KIT: 3L 7 FR X 8 IN/ASK-15703-PRH; MULTILUMEN PI CVC KIT: 3L 7 FR X 20 CM/CDC-15703-P1A; PI CVC KIT: 3-L 7 FR X 6IN (16 CM)/NA-12703-PCDC; PI CVC KIT: 3-L 7 FR X 8IN (20 CM)/NA-15703-PCDC; CVC KIT: 3-LUMEN 5.5 FR X 8 CM/AK-25553; 2-L CVC KIT: 4 FR X 5 CM/CDC-22402-X1A; 2-L CVC KIT: 5 FR X 5 CM/CDC-22502-X1A; 2-L CVC KIT: 4 FR X 8 CM/CDC-25402-X1A; 2-L CVC KIT: 5 FR X 8 CM/CDC-25502-X1A; 3-L CVC KIT: 5.5 FR X 8 CM/CDC-25553-X1A; 3-L CVC KIT: 5.5 FR X 13 CM/CDC-26553-X1A; CVC KIT 3L: 12 FR X 16 CM AGB/AK-22123-CDC; CVC KIT: 3-LUMEN 12 FR X 16 CM/AK-22123-F; CVC KIT: 2-LUMEN 4 FR X 5 CM/AK-22402; CVC KIT: 2-LUMEN 5 FR X 5 CM/AK-22502; CVC KIT: 16 GA X 8IN/AK-24301-SK; CVC KIT: 2-LUMEN 4 FR X 13 CM/AK-24402; CVC KIT: 3-LUMEN 7 FR X 30 CM/AK-24703-ASK; CVC KIT 3L: 12FR X 20 CM AGB/AK-25123-CDC; CVC KIT: 3-LUMEN 12 FR X 20 CM/AK-25123-F; CVC KIT: 2-LUMEN 4 FR X 8 CM/AK-25402; CVC KIT: 2-LUMEN 5 FR X 8 CM/AK-25502; CVC KIT: 3-LUMEN 5.5 FR X 13 CM/AK-26553; LBCVC KIT: 3L 12 FR X 16 CM AGB/CDC-22123-1A; LBCVC KIT: 3L 12 FR X 16 CM AGB/CDC-22123-X1A; CVC KIT: 16 GA X 20 CM/CDC-24301-1A; PI CVC KIT: 2L 7 FR X 16 CM AGB/AK-22702-P1A; PI CVC KIT: 2L 7 FR X 16 CM AGB/CDC-22702-XP1A; CVC KIT: 3L 7 FR X 20 CM/ASK-45703-CPR; MULTILUMEN PI CVC KIT: 3L 7 FR X 16 CM/ASK-42703-AKP1A; MULTI-LUMEN PI CVC KIT: 3-L 7 FR X 6IN/ASK-42703-KH; PI CVC KIT: 3L 7FR X 16CM AGB+/ASK-42703-MGH1; MULTI LUMEN PI CVC KIT: 3L 7 FR X 6IN/ASK-42703-PCCH2; PI CVC KIT: 3LUMEN 7 FR X 6IN (16 CM)/ASK-42703-PFS1; PI CVC KIT: 3L 7 FR X 16 CM AGB+/ASK-42703-PNO2; MULTI LUMEN PI CVC KIT: 3L 7 FR/ASK-42703-PSCH1; MULTILUMEN PI CVC KIT: 2L 8 FR X 16 CM/ASK-42802-AKP1A; CVC KIT: 2L 8 FR X 16CM/ASK-42802-LMDTG1; PI CVC KIT: 2L 8 FR X 6 IN (16 CM) AGB+/ASK-42802-PUCI1; PI CVC KIT: 2L 8 FR X 16 CM AGB+/ASK-42802-PUMH; PI CVC KIT: 2L 8 FR X 16 CM AGB+/ASK-42802-UMM; PI CVC KIT: 4-L 8.5 FR X 6 IN/ASK-42854-AKP1A; PI CVC KIT: 4L 8.5FR X 16CM AGB+/ASK-42854-MGH; MULTILUMEN PI CVC KIT: 3L 7 FR X 20 CM/ASK-45703-AKP1A; PI CVC KIT: 3L 7 FR X 20CM AGB+/ASK-45703-MGH; MULTI LUMEN PI CVC KIT: 3L 7 FR X 8 IN/ASK-45703-PCCH2; MULTI LUMEN PI CVC KIT: 3L 7 FR X 8 IN/ASK-45703-PECL1; PI CVC KIT: 3 LUMEN 7 FR X 8 IN (20 CM)/ASK-45703-PFS1; PI CVC KIT: 3L 7 FR X 8 IN (20 CM) AGB+/ASK-45703-PHM1; PI CVC KIT: 3L 7 FR X 20 CM AGB+/ASK-45703-PHU; PI CVC KIT: 3L 7 FR X 20 CM AGB+/ASK-45703-PMSG1; MULTILUMEN PI CVC KIT: 3L 7 FR X 20 CM/ASK-45703-PNCB; MULTILUMEN CVC KIT: 3L 7 FR X 20 CM/ASK-45703-PPCM; PI CVC KIT: 3-LUMEN 7 FR X 8 IN (20 CM)/ASK-45703-PRH; MULTILUMEN PI CVC KIT: 3L 7 FR X 8 IN/ASK-45703-PSJ2; PI CVC KIT: 3L 7 FR X 20 CM/ASK-45703-PSVM; MULTI LUMEN PI CVC KIT: 3L 7 FR X 20 CM/ASK-45703-PUHS; PI CVC KIT: 3L 7 FR X 20 CM AGB+/ASK-45703-PUKL; PI CVC KIT: 3L 7FR X 20CM AGB+/ASK-45703-PUMF1; PI CVC KIT: 3L 7 FR X 8 IN (20 CM)/ASK-45703-PUR1; PI CVC KIT: 3L 7 FR X 20 CM AGB+/ASK-45703-RHR1; MULTILUMEN PI CVC KIT: 3L 7 FR X 20 CM/ASK-45703-WA; MULTI LUMEN PI CVC KIT: 2L 8 FR X 8 IN/ASK-45802-AKP1A; PI CVC KIT: 4L 8.5 FR X 20 CM/ASK-45854-AKP1A; PI CVC KIT: 4L 8.5FR X 20CM AGB+/ASK-45854-MGH; PI CVC KIT: 4L 8.5 FR X 8IN/ASK-45854-PCCH2; CVC KIT: 4L 8.5 FR X 20 CM AGB/ASK-45854-PNM; MULTI LUMEN CVC KIT: 4L 8.5 FR X 8 IN/ASK-45854-PPCM; PI CVC KIT: 4L 8.5 FR X 20 CM AGB+/ASK-45854-PUCH2; MULTILUMEN PI CVC KIT: 2L 7 FR X 20 CM/ASK-46702-PWBH1; MULTILUMEN CVC KIT: 2L 8 FR X 16 CM/CDC-42802-P1A; PI CVC KIT: 3-L 7 FR X 20 CM AGB/CDC-45703-PA1A; CVC KIT: 2L 8 FR X 6IN (16 CM)/ASK-42802-ECL4; PI CVC KIT: 3-L 7 FR X 16 CM AGB+/AK-42703-P1A; PI CVC KIT: 2-L 8 FR X 16 CM AGB+/AK-42802-P1A; PI CVC KIT: 4-L 8.5 FR X 16 CM AGB+/AK-42854-P1A; PI CVC KIT: 3-L 7 FR X 20 CM AGB+/AK-45703-P1A; PI CVC KIT: 2-L 8 FR X 20 CM AGB
Lidocaine, Bupivacaine, and 0.9% sodium chloride, the subject of a supplier recall, were included into kits and sets. The supplier was found to have quality issues and limited reports of drug ineffectiveness, and if sterility of a water-based injectable product is compromised this could lead to serious or life-threatening injuries.
- 2026-06-13Open, ClassifiedNonconforming Material/Component
Description/REF: ACCESS TRAY/ASK-04001-JHH; ACCESS TRAY/ASK-04001-LMDTG; PI CVC KIT: 3 LUMEN 7 FR X 6 IN (16 CM)/ASK-12703-PSPH1; 3L CVC KIT: 7 FR X 16 CM/ASK-12703-WMC2; MULTILUMEN PI CVC KIT: 3L 7 FR X 20CM/ASK-15703-LMDT1; MULTILUMEN PI CVC KIT: 3L 7 FR X 20CM/ASK-15703-LMDTG1; MULTILUMEN PI CVC KIT: 3L 7 FR X 8 IN/ASK-15703-PVH; 1L CVC KIT: 16 GA X 8 IN (20CM)/ASK-24301-JHH1; CVC KIT: 16 GA X 16 CM/CDC-24306-1A; CVC KIT: 3-L 7 FR X 30 CM ANTIMICROBIAL/CDC-24703-X1A; LBCVC KIT: 3L 12 FR X 20 CM AGB/CDC-25123-1A; CVC KIT: 2L 8 FR X 6IN (16 CM)/ASK-42802-ECL3; PI CVC KIT: 3L 7 FR X 16 CM AGB+/ASK-42703-ACH; PI CVC KIT: 3L 7 FR X 16 CM AGB+/ASK-42703-BJC1; MULTI LUMEN PI CVC KIT: 3L 7 FR X 16 CM/ASK-42703-DU1; PI CVC KIT: 3L 7 FR X 16 CM AGB+/ASK-42703-EMC; MULTI LUMEN PI CVC KIT: 3L 7 FR X 6IN/ASK-42703-LMDT1; MULTI LUMEN PI CVC KIT: 3L 7 FR X 6 IN/ASK-42703-LMDTG1; PI CVC KIT: 3L 7 FR X 16 CM AGB+/ASK-42703-MCY1; MULTILUMEN PI CVC KIT: 3L 7 FR X 6 IN/ASK-42703-NS1; PI CVC KIT: 3L 7 FR X 16 CM AGB+/ASK-42703-PAGP1; PI CVC KIT: 3L 7 FR X 6 IN (16 CM)/ASK-42703-PAM1; PI CVC KIT: 3L 7 FR X 16 CM AGB+/ASK-42703-PAMC2; PI CVC KIT: 3L 7 FR X 16 CM AGB+/ASK-42703-PAU1; MULTI LUMEN PI CVC KIT: 3L 7 FR X 16/ASK-42703-PB1; PI CVC KIT: 3L 7 FR X 16CM AGB+/ASK-42703-PBSWH2; MULTI LUMEN PI CVC KIT: 3L 7 FR X 16 IN/ASK-42703-PCAM1; MULTILUMEN PI CVC KIT: 3L 7 FR X 16 CM/ASK-42703-PCSJ2; MULTI LUMEN PI CVC KIT: 3L 7 FR X 6 IN/ASK-42703-PECL2; MULTI LUMEN PI CVC KIT: 3L 7 FR X 6 IN/ASK-42703-PGM4; PI CVC KIT: 3L 7 FR X 16 CM AGB+/ASK-42703-PHHN1; MULTI LUMEN CVC KIT: 3L 7 FR X 6 IN/ASK-42703-PLC; PI CVC KIT: 3L 7 FR X 16 CM AGB+/ASK-42703-PMEM; PI CVC KIT: 3L 7 FR X 16 CM AGB+/ASK-42703-PMHC1; PI CVC KIT: 3L 7 FR X 16 CM AGB+/ASK-42703-PNHS1; PI CVC KIT: 3L 7 FR X 16 CM AGB+/ASK-42703-POHU2; MULTILUMEN PI CVC KIT: 3L 7 FR X 6/ASK-42703-POSU2; MULTILUMEN CVC KIT 7 FR X 6 IN (16 CM)/ASK-42703-PTJH; PI CVC KIT: 3L 7 FR X 16 CM AGB+/ASK-42703-PUCH2; PI CVC KIT: 3L 7 FR X 6 IN (16 CM) AGB+/ASK-42703-PUCI1; PI CVC KIT: 3L 7 FR X 16 CM AGB+/ASK-42703-PUHC2; PI CVC KIT: 3L 7 FR X 16 CM AGB+/ASK-42703-PUMH; MULTI-LUMEN PI CVC KIT: 3-L 7 FR/ASK-42703-PUPM1; MULTI LUMEN PI CVC KIT: 3L 7 FR X 6 IN/ASK-42703-SHUF2; MULTI LUMEN PI CVC KIT: 3L 7 FR/ASK-42703-SL1; CVC KIT: 3 LUMEN 7 FR X 6 IN (16 CM)/ASK-42703-UMC; PI CVC KIT: 3L 7 FR X 6 IN (16 CM) AGB+/ASK-42703-WHH; CVC/PSI KIT: 2 LUMEN 8 FR X 6 IN/ASK-42802-CHM; CVC KIT: 2L 8 FR X 16 CM/ASK-42802-LMDT1; PI CATHETER 2L: 8FR X 16CM AGB+/ASK-42802-MCY1; PI CVC KIT: 2L 8FR X 16CM AGB+/ASK-42802-PBSWH2; MULTILUMEN CVC KIT: 2L 8 FR X 6/ASK-42802-POSU2; PI CVC KIT: 2L 8 FR X 16 CM AGB+/ASK-42802-PUNCC2; PI CVC KIT: 2-L 8 FR/ASK-42802-PUPM1; PI CVC KIT: 2L 8 FR/ASK-42802-TGH1; PI CVC KIT: 4L 8.5 FR X 16 CM AGB+/ASK-42854-BJC1; CVC KIT: 4L 8.5 FR X (16CM) AGB+/ASK-42854-PBMH; PI CVC KIT: 4L 8.5FR X 16CM AGB+/ASK-42854-PMM; PI CVC KIT: 4L 8.5 FR X 16 CM AGB+/ASK-42854-PUCH2; PI CVC KIT: 3L 7 FR X 20 CM AGB+/ASK-45703-ACH; 3L CVC KIT: 7 FR X 20 CM AGB+/ASK-45703-ARM; PI CVC KIT: 3L 7 FR X 20 CM AGB+/ASK-45703-BJC1; PI CVC KIT: 3L 7 FR X 20 CM AGB+/ASK-45703-BLH; MULTI LUMEN PI CVC KIT: 3L 7 FR X 20 CM/ASK-45703-DU1; PI CVC KIT: 3L 7 FR X 20 CM AGB+/ASK-45703-HHC4; PI CVC KIT: 3L 7 FR X 20 CM AGB+/ASK-45703-LMDT1; PI CVC KIT: 3L 7 FR X 20 CM AGB+/ASK-45703-LMDTG1; PI CVC KIT: 3L 7 FR X 20 CM AGB+/ASK-45703-MCY1; PI CVC KIT: 3L 7 FR X 20 CM AGB+/ASK-45703-NO; PI CVC KIT: 3L 7 FR X 20 CM AGB+/ASK-45703-NS1; MULTI LUMEN PI CVC KIT: 3L 7 FR X 8 IN/ASK-45703-PADV1; PI CVC KIT: 3L 7 FR X 20 CM AGB+/ASK-45703-PAGP1; MULTI LUMEN CVC KIT: 3L 7 FR X 8 IN/ASK-45703-PAMC1; MULTI LUMEN CVC KIT: 3L 7 FR X 8 IN/ASK-45703-PAU1; PI CVC KIT: 3L 7FR X 20CM AGB+/ASK-45703-PBSWH2; PI CVC KIT: 3L 7 FR X 20 CM AGB+/ASK-45703-PCAM1; MULTILUMEN PI CVC KIT: 3L 7 FR X 20 CM/ASK-45703-PCSJ2; PI CVC KIT: 3L 7 FR X 8 IN (20 CM) AGB+/ASK-45703-PDM1; MULTI LUMEN PI CVC KIT: 3L 7 FR X 20 CM/ASK-45703-PECL2; MULTI LUMEN PI CVC KIT: 3L 7 FR X 8 IN/A
Lidocaine, Bupivacaine, and 0.9% sodium chloride, the subject of a supplier recall, were included into kits and sets. The supplier was found to have quality issues and limited reports of drug ineffectiveness, and if sterility of a water-based injectable product is compromised this could lead to serious or life-threatening injuries.
- 2026-06-12Open, ClassifiedProcess control
Medline convenience kit: IV START KIT W/HUBGUARD DYNDV2662
Kits contain recalled lot of Ferndale Laboratories MASTISOL Liquid Adhesive. Butyrate tubing may crack during actuation and render product unusable for application.
- 2026-05-07Open, ClassifiedProcess control
Medline Convenience Kits: 1) PICC CATHETER INSERTION TRAY, Model Number: CVI4300; 2) OSC SHERMAN KNEE ARTHRO BASIC, Model Number: DYKM1977C; 3) KIT ACES INSERT PEG, Model Number: DYKMBNDL130; 4) KIT ACES INSERT PEG, Model Number: DYKMBNDL130A; 5) KIT ACES INSERT PERCUTANEOUS T, Model Number: DYKMBNDL4; 6) NICU LINE CHANGE TRAY, Model Number: LC295
Medline has identified issues related to calibration of the equipment used to sterilize and package the devices. All products were exposed to the validated sterilization and packaging cycles; however, the identified calibration issues have the potential to impact the sterility assurance level (SAL) of the Recalled Products.
- 2026-04-30Open, ClassifiedUnder Investigation by firm
Medline or Centurion medical convenience kits, containing Webcol Large Alcohol Prep Pads, labeled as: 1. NEONATAL IV START KIT (Centurion), Medline Kit SKU IV8310E; 2. IV SECUREMENT KIT (Centurion), Medline Kit SKU IVS1700; 3. IV START KIT (Centurion), Medline Kit SKU IV8675; 4. NEONATAL IV SECUREMENT KIT W/SHIELD(Centurion), Medline Kit SKU IVSSTK12; 5. IV START & SECUREMENT KIT (Centurion), Medline Kit SKU IV6940; 6. IV START KIT WITHOUT TUBING, Medline Kit SKU IV8775; 7. NEONATAL IV SECUREMENT KIT W/SHIELD, Medline Kit SKU IVSSTK12; 8. IV SECUREMENT KIT (Centurion), Medline Kit SKU IVS1700; 9. IV START KIT, Medline Kit SKU IV8675; 10. NEONATAL IV START KIT (Centurion), Medline Kit SKU IV8310E; 11. IV START & SECUREMENT KIT (Centurion), Medline Kit SKU IV6940; 12. IV START KIT WITHOUT TUBING, Medline Kit SKU IV8775.
Medline Industries, LP is issuing a recall for specific item(s) and lot(s) of Medline Kits containing Cardinal Health Webcol Large Alcohol Prep Pads. Cardinal Health has deemed Webcol Large Alcohol Prep Pads to be non-sterile following the discovery of a contaminant (Paenibacillus phoenicis) during a routine sterilization dose audit.