LIPClass 2

Enzyme Linked Immunoabsorption Assay, Treponema Pallidum

FDA adverse event reports and recall history for enzyme linked immunoabsorption assay, treponema pallidum (product code LIP), from the public MAUDE corpus and the live FDA recall database.

Total reports
502
Deaths
0
Injuries
9
Malfunctions
490

Reports per year

12
13
14
15
16
17
18
19
20
21
22
23
24
25
26

Source: FDA adverse event reports by year received, 2012–2026. Reporting paused twice in 2026 during FDA reporting-system changes and has since resumed.

Recent recalls

  • 2026-08-14Open, ClassifiedUnder Investigation by firm

    Siemens Healthineers Immulite 2000 Systems SYP Syphilis Screen REF:L2KSY2(D)/10471981 IVD, RxOnly

    Syphilis Screen assay may contain a negative patient bias resulting in low reactive patient results being reported as nonreactive.

  • 2026-08-14Open, ClassifiedUnder Investigation by firm

    Siemens Healthineers Immulite 2000 Systems SYP Syphilis Screen REF(s):L2kSY2/10489085; L2KSY6/10488319 IVD, RxOnly

    Syphilis Screen assay may contain a negative patient bias resulting in low reactive patient results being reported as nonreactive.

  • 2014-12-16TerminatedUnder Investigation by firm

    Trinity biotech Captia (TM) Syphilis IgM Capture Test Kit, Product No./REF 800-935, Test Kit for 96 Determinations, IVD for In Vitro Diagnostic use; an antibody class capture enzyme immunoassay for the detection of IgM antibodies to T. pallidum as an aid to the identification of active syphilis in human serum.

    Through in-house routine real time stability monitoring of Trinity's Captia Syphilis IgM Capture Test Kit, Lot 033, the firm identified a failure of the kit to meet its labeled expiry dating of 6 months.

  • 2013-12-26TerminatedProcess design

    Captia Syphilis-G Test Kit Product Usage: This is an enzyme immunoassay for the qualitative detection of IgG antibodies to T. pallidum in serum specimens, to be used in conjunction with non-treponemal testing to provide serological evidence of infection with T. pallidum ( the agent of syphilis). It is also intended for testing of serum or plasma specimens to screen blood and/or plasma donors to exclude a history of syphilis.

    Trinity Biotech recalled Trinity Biotech Captia Syphilis IgG kits due to false negative results.

  • 2012-08-20TerminatedComponent design/selection

    Siemens ADVIA Centaur Syphilis (SYPH) Assay , 200 ReadyPack Reference Number 10492493 Product Usage: The ADVIA Centaur Syphilis (SYPH) assay is an in vitro diagnostic immunoassay for the qualitative determination of antibodies to Treponema pallidum in human serum or plasma (EDTA, lithium or sodium heparinized, citrate) using the ADVIA Centaur and ADVIA Centaur XP systems as an aid in the diagnosis of syphilis

    Syphilis Assay Interference with HBsAg Assay

  • 2008-06-11TerminatedNonconforming Material/Component

    BIOPLEX 2200 SYPHILIS IgG Kit: 100 tests - Catalog No. 665-1450 - manufactured by Bio-Rad Laboratories in Redmond, WA 98052. The product is a multiplex flow immunoassay intended for the qualitative detection of Treponema pallidium IgG antibodies in human serum.

    False negative results due to reagent packs exhibiting low signal.

  • 2007-11-09TerminatedLabeling Change Control

    BioPlex 2200 System, Cat. No. 665-1460A containing APF CD SW2_v1., Syphilis IgG IFU Packet contains the Syphilis IgG Assay Protocol File LAPF CD

    Mislabeling: Reporting terminology in the Syphilis IgG APF CD is not consistent with the distributed Instructions for Use. (Non-Reactive and Reactive rather than Negative and Positive)

  • 2005-04-28TerminatedOther

    Trep-Chek Syphilis Test Kit, 960 tests, Catalog No. TP-960, Distributed by DiaSorin, Inc. 1951 Northwestern Ave, Stillwater, MN 55082-0285 USA. Manufactured by Phoenix Bio-Tech Corp., 6910 Kitimat Road, Unit #1, Mississauga, Ontario, Canada L5N 5M2.

    Package insert incorrectly states that specimen diluent is ready to use, however specimen diluent bottle in kit states that the diluent must be diluted to one liter.

  • 2004-12-17TerminatedOther

    The Is-Syphilis TREP-CHEK (TM) Test Kit is a confirmatory in vitro enzyme immunoassay for the qualitative detection of Treponema pallidum IgG antibodies in human serum or plasma. The reagents can be used either manually or in conjunction with the MAGO Plus or APTUS Automated EIA Processors. The FDA has not cleared this product for use in screening blood or plasma donors. The kit is labeled with an expiration date of Mar 04 and requires storage at 2-8 degree Centigrade.The non conforming kit component is the Conjugate that consists of a glass bottle with red cap containing 30 ml goat anti-human IgG labeled with horseradish peroxidase.

    Several customers complained that either the negative control index value exceeded the upper control limit or there was very low activity of the cut off calibrator causing patient sample test runs to be called invalid.

  • 2004-07-20TerminatedOther

    Product is packaged in a box and is labeled: Syphilis TREP-CHEK No. 720-100-10, 960 test, For in Vitro Diagnostic Use Lot 71303 Exp. Jun 04 Diamedix, A subsidiary of IVAX Diagnostics, Inc. MIAMI, FL 33127

    The test kit may have the potential to give erroneous results in that it may give higher frequency of equivocal/low positive results.

Monitor enzyme linked immunoabsorption assay, treponema pallidum automatically