KYZClass 1

Syringe, Irrigating (Non Dental)

FDA adverse event reports and recall history for syringe, irrigating (non dental) (product code KYZ), from the public MAUDE corpus and the live FDA recall database.

Total reports
602
Deaths
1
Injuries
49
Malfunctions
541

Reports per year

12
13
14
15
16
17
18
19
20
21
22
23
24
25
26

Source: FDA adverse event reports by year received, 2012–2026. Reporting paused twice in 2026 during FDA reporting-system changes and has since resumed.

Recent recalls

  • 2026-07-10Open, ClassifiedUnder Investigation by firm

    Rapid Refill Continuous Injection System, UPN M00566001

    Devices contain recalled Medline Namic Angiographic Control Syringe with Rotating Adaptor. There is a risk of syringe loosening or disconnecting from the manifold, resulting in loose connection or complete disconnection. May lead to difficulty connecting syringe, inability to aspirate or inject properly, fluid leakage, or separation of the syringe from the system, potentially requiring device exchange and prolonging the procedure.

  • 2024-09-30Open, ClassifiedUnder Investigation by firm

    Medline Contro-Bulb Syringe, REF DYND20125; bulb irrigation syringe

    Packaging material was updated for the Bulb Irrigation Syringe (DYND20125), and additional testing done at Medline Corporate indicated the potential for the sterile barrier to be breached during transportation. This only affects two lot numbers (96922110001 and 96923100001).

  • 2024-02-16Open, ClassifiedNonconforming Material/Component

    Dover" IRRIGATION 1200 CC TRAY, 60 CC PISTON SYRINGE, STERILE SALINE, TIP PROTECTOR, ALCOHOL, LIDDED

    Convenience kits were manufactured and distributed with components which were subsequently recalled by Nurse Assist.

  • 2023-02-10Open, ClassifiedUnder Investigation by firm

    Surgical convenience kits labeled as: CENTURION MEDICAL PRODUCTS IR INSTRUMENT TRAY, Reorder Number SUT10675

    The recall is due to the perforated bag not allowing for outside of the kit wrapping to be sterile, therefore, only the contents inside the kits wrapping are sterile.

  • 2016-04-14TerminatedPackaging

    Catalog Number: 900020 IRRIGATION TRAY WITH IRRIGATION BULB SYRINGE Used by medical staff to perform surgical procedures and patient care procedures such as wound healing, suture removals, irrigate wounds, etc.

    Recall initiated due to inadequate validation/qualification of sterilization processes, and package integrity for products released for distribution as sterile.

  • 2016-02-16TerminatedPackaging process control

    REF 0038460 Toomey Syringe 70cc Syringe with Catheter Tip and Luer Tip Adapters, Single Use, Rx Only, Latex Free, 50 units. Product Usage: Product is intended for Resectoscope irrigation, catheter irrigation and Foley catheter inflation.

    Report by a customer of an open package seal.

  • 2015-09-03TerminatedPackaging

    IRRIGATION TRAY W/BULB SYRINGE CUSTOMED 50/CS Used by medical staff to perform patient care procedures such as wound healing, suture removals, irrigate wounds, etc.

    Recall initiated due to inadequate validation/qualification of sterilization processes, and package integrity for products released for distribution as sterile.

  • 2013-07-25TerminatedIncorrect or no expiration date

    Medtronic Preimplantation Test Kit, Catalog No. 21047. The kit is indicated for use with Medtronic CSF-Flow Control Valves and Delta Valves, when a simple preimplantation test is desired to verify that the valve conforms to labeled product specifications.

    Medtronic Neurosurgery is recalling the Medtronic Preimplantation Test Kit because the outer carton had expiration dates that were incorrect. The date on the outer carton is later than the expiration date for one or more of the individually packaged sterile components in the kit.

  • 2012-05-11TerminatedLabeling mix-ups

    HemaSyst, Dual Cannula Tip with Adapter 16 ga. x 4" (10.2 cm). Product is labeled in part:"***Pouch label***HAEMACURE***HemaSyst***tm***Contents: One ***DUAL CANNULA TIP***WITH ADAPTER***16 ga. x 4" (10.2 cm)***REF H-1604*** CE 0297***LOT 111144***2014/10***40680b/20004-02***CAUTION: U.S. Federal Law restricts this device to sale by or on the order of a licensed physician (or properly licensed practitioner).***Contents of unopened undamaged package are sterile***CE 0297***Manufactured by: ***Micromedics*** St. Paul, MN 55121-1385 USA***Distributed by:***Haemacure Corporation***Sarasota, FL 34236 USA***Toll Free 1-877-872-4583***www.haemacure.com***Box label***Contents: 5 packages of 1 each***DUAL CANNULA TIP***WITH ADAPTER***16 ga. x 4" (10.2 cm)***REF H-1604***CE 0297***STERILE EO***LOT 11144***2014/10***40681B/20544***". Sterile, single-use instrument for the application of two liquids.

    This product has been recalled due to the lot number being different on the box and pouch. The lot number on the box label was incorrectly printed as 11144 instead of 111144. The pouch label referenced the correct lot number, 111144.

  • 2012-03-21TerminatedPackaging

    Irrigation Tray w/Bulb syringe, catalog# 900-020

    The firm has determined that there is a possibility that packaging seals may be compromised. The issue could result in an injury to the patient due to product contamination or loss of sterility condition.