Monitor, Bed Patient
FDA adverse event reports and recall history for monitor, bed patient (product code KMI), from the public MAUDE corpus and the live FDA recall database.
- Total reports
- 3,298
- Deaths
- 80
- Injuries
- 301
- Malfunctions
- 2,829
Reports per year
Source: FDA adverse event reports by year received, 2012–2026. Reporting paused twice in 2026 during FDA reporting-system changes and has since resumed.
Recent recalls
- 2015-03-03TerminatedDevice Design
The I-Cart is used to store, transport, and power video equipment used in medical procedures.
The transformers installed on carts used for Richard Wolf medical video systems may overheat causing smoke and black plastic material to leak from the cart chassis.
- 2014-08-26TerminatedComponent design/selection
CURBELL MEDICAL CareSense Wireless Advanced LCD Bed and Chair Monitor, MODEL # CSM-BC400; --- COMMON/USUAL NAME: Bed Patient Monitor; CLASSIFICATION NAME: Bed Patient Monitor --- Monitor is connected to a sensor pad that monitors the patient if they attempt to arise from a bed, chair, floor mat, or toilet seat. The monitor will sound an alarm.
The firm became aware of a potential problem that was initiated by a customer complaint. After consultation with the manufacturer, it was discovered that a resistor was incorrectly placed within the circuit board on the monitor. This change to the resistor was a planned change to address a product improvement (improve battery drain). However, this modification rendered the monitor's alarm via the nurse call communication port to not function.
- 2013-06-26TerminatedNonconforming Material/Component
Code Alert Advanced 4-Way Care Solution, CA520 System, PN 9600-1600, RF Technologies. This product is used to alert caregivers when a patient at risk for falls is leaving a bed or chair.
RF Technologies, Inc. has initiated a recall involving CA520 Code Alert Integrated Care Management Advanced 4-Way Care Solution . Due to a firmware error, the alarm may not be transmitted to the system server immediately.
- 2013-02-23TerminatedSoftware design
QuietCare-Networked product, Facility Server/model: QC101601; The QuietCare system is intended to detect and analyze residents' movements.
Care Innovations detected a software anomaly: During the engineering investigation into the cause of why a Wander Alert was not generated, a defect in the implementation of the Wander and Night Motion ADLs was discovered.
- 2012-09-28TerminatedDevice Design
Tabs Professional Monitor, includes one wall bracket, Model 25022. Stanley Security Solutions, Inc., Lincoln, NE. Designed to help reduce the risk of falls by alerting caregivers when a resident is leaving a bed, chair, room or wheelchair.
The monitor may fail to sound an alarm
- 2012-09-28TerminatedDevice Design
Tabs Professional Monitor, without wall bracket, Model 25023. Stanley Security Solutions, Inc., Lincoln, NE. Designed to help reduce the risk of falls by alerting caregivers when a resident is leaving a bed, chair, room or wheelchair.
The monitor may fail to sound an alarm
- 2012-09-28TerminatedDevice Design
Tabs Professional Monitor, without pull cord or wall bracket, Model 25025. Stanley Security Solutions, Inc., Lincoln, NE. Designed to help reduce the risk of falls by alerting caregivers when a resident is leaving a bed, chair, room or wheelchair.
The monitor may fail to sound an alarm
- 2012-09-28TerminatedDevice Design
Tabs Professional Voice + Monitor, includes one wall bracket, Model 25222. Stanley Security Solutions, Inc., Lincoln, NE. Designed to help reduce the risk of falls by alerting caregivers when a resident is leaving a bed, chair, room or wheelchair.
The monitor may fail to sound an alarm
- 2012-09-28TerminatedDevice Design
Tabs Professional Voice + Monitor, with wire bracket, Model 25223. Stanley Security Solutions, Inc., Lincoln, NE. Designed to help reduce the risk of falls by alerting caregivers when a resident is leaving a bed, chair, room or wheelchair.
The monitor may fail to sound an alarm
- 2012-04-28TerminatedComponent design/selection
Micro-Tech Informer Plus Silver Monitor, Model 81830. The firm name on the label is Stanley Security Solutions, Inc., Lincoln, NE. Product Usage: The system is a bed exit system designed to indicate, by alarm or signal, when someone attempts to leave the bed. The system consists of a control unit that is mounted on the bed and a pressure sensitive bed sensor pad that is placed across the width of the bed under the mattress or just beneath the sheets and overlays. The control unit is powered by means of a plug-in type power supply and an alarm cord is used to interface the control unit with the nurse call system.
Connection between the call cord and the receptacle may not make a correct connection resulting in a continuous or intermittent (false) signal to the nurse call system
Monitor monitor, bed patient automatically
DeviceWatch watches FDA adverse events and recalls for the products you care about, summarizes clinical narratives with AI and alerts you when a safety signal emerges.