JTCClass 1

Device, Microtiter Diluting/Dispensing

FDA adverse event reports and recall history for device, microtiter diluting/dispensing (product code JTC), from the public MAUDE corpus and the live FDA recall database.

Total reports
7,714
Deaths
0
Injuries
23
Malfunctions
5,476

Reports per year

09
10
11
12
13
14
15
19
20
21
22
23
24
25
26

Source: FDA adverse event reports by year received, 2009–2026. Reporting paused twice in 2026 during FDA reporting-system changes and has since resumed.

Recent recalls

  • 2023-04-20Open, ClassifiedSoftware design

    BD Kiestra InoqulA+ with BD Kiestra" InoqulA+" and BeA Software version 5.1 and 5.1.1 as part of the Icefall A platform. An in vitro diagnostic medical device intended to automate specimen processing according to user-defined procedures and protocols. Catalog (Ref) No. : 447213

    Upon installation of BD Kiestra" InoqulA+" and BeA version 5.1 and 5.1.1 as part of the Icefall A platform, plate information was not visible in Synapsys" after processing has occurred. This could possibly lead to a delayed diagnosis and/or treatment or need for specimen recollection streaking plated media, and inoculating tubes and slides. In Semi-Automated (SA) mode, plates are automatically selected, barcoded, streaked in a pre-configured pattern while the user manually inoculates plates, tubes, and slides. An optional biosafety cabinet on the SA module provides personnel, product, and environmental protection. The InoqulA+" solution is indicated for use in the clinical laboratory.

  • 2013-08-30TerminatedDevice Design

    WASP (Walk Away Specimen Process). Automatic Planting and Streaking Instrument Catalog number: W086 WASP is a fully automated system used to process microbiological specimens in liquid phase for the investigation of infectious microbes.

    The recall of the WASP (Walk Away Specimen Process) instrument was initiated because Copan Italia SpA has upgraded the software concerning the broth inoculation table feature. The upgrade has been considered necessary from the manufacturer in order to eliminate the very low risk of rotation of the broth table when the door is open.

  • 2009-09-09TerminatedProcess control

    300 Microliter CO-RE Tips for use with Microlab STAR, manufactured by Hamilton Company, Reno, NV. Product is a disposable product used with Microlab STAR series Instruments, which are microtiter diluting and dispensing devices.

    Product Defect-- some tips from the mold cavity 28 are too short and do not always aspirate or dispense liquid correctly.

  • 2009-04-17TerminatedProcess control

    300 microliter CO-RE tips for use with Microlab STAR series instruments, Part Number 235902, 5,760 tips per case, manufactured by Hamilton Company, Reno, NV. The products are a disposable product that are used with the Microlab STAR series instruments, which are microtiter diluting and dispensing devices.

    Some tips may be occluded and are unable to aspirate or dispense liquid.

  • 2008-02-08TerminatedError in labeling

    Hamilton Sample Carriers for the ML STAR line (SMP-CAR-24). Product Code: 866.2500; Part Number: 173400. Hamilton Company, Reno, NV 89520 (Accessory on the Microlab STAR series instruments.)

    Incorrectly labeled-- Product has the wrong barcode labeling. The barcode error will not influence the results of testing. The instrument will discover the error and post an error notice.

  • 2006-02-14TerminatedOther

    Microlab AT, part numbers 135001, 135001OOC, 135002, 135003, 135005, 135006, 135006R, 135007, 135008, 135016, 135028, 135029, 936400, 936400BLU. Microlab AT+ and Microlab AT+2, part numbers 142000, 142001, 142001R, 142002, 142003, 142005, 142006, 142006R, 142007, 142008, 142009, 142015, 142017, 142035, 142036

    Heat sinking on power boards may not operate as intended and the board may cease to operate.

  • 2005-04-13TerminatedOther

    Version 7 Software for wash program on Bio Tek Automated Microplate Washer Model ELx50 which performs the washing steps for various programmed mictotiter plate assays.

    When software was updated for the Washer program of the Bio Tek Automated Microplate Washer Model ELx50, the software did not automatically clear old versions of the wash program when new ones were added.

  • TerminatedSoftware design

    BD Kiestra InoqulA Software Version 20.3.IVD automated specimen processing Catalog Number: 447202

    An anomaly is present in InoqulA / InoqulA+ software version 20.3, has the potential to cause a mismatch between a specimen and plate

  • TerminatedSoftware design

    BD Kiestra InoqulA+ Software Version 20.3. IVD automated specimen processing Catalog Number : 447213

    An anomaly is present in InoqulA / InoqulA+ software version 20.3, has the potential to cause a mismatch between a specimen and plate

Monitor device, microtiter diluting/dispensing automatically