Activated Whole Blood Clotting Time
FDA adverse event reports and recall history for activated whole blood clotting time (product code JBP), from the public MAUDE corpus and the live FDA recall database.
- Total reports
- 321
- Deaths
- 10
- Injuries
- 25
- Malfunctions
- 269
Reports per year
Source: FDA adverse event reports by year received, 2012–2026. Reporting paused twice in 2026 during FDA reporting-system changes and has since resumed.
Recent recalls
- 2025-12-03Open, ClassifiedPackaging process control
Hemochron Activated Clotting Time Low-Range Test Cuvette, REF: ACT-LR, to be used with the Hemochron Signature ELITE Whole Blood Microcoagulation System
Test cuvettes, used with an assay for monitoring heparin anticoagulation, may have a foreign object that has sharp edges and could pose a risk of injury if not detected prior to handling.
- 2025-11-18Open, ClassifiedUnder Investigation by firm
Medtronic HR-ACT (High Range Activated Clotting Time Cartridges), REF 402-03
Medtronic personnel observed trace amounts of dry blood on the external carton label and Instructions for Use (IFU) in five boxes of one lot of ACT Cartridges.
- 2011-02-16TerminatedDevice Design
Celite ACT Cartridge Cartridge is useful for monitoring patients receiving heparin for treatment of pulmonary embolism or venous thrombosis, and for monitoring anticoagulation therapy in patients undergoing medical procedures such as catheterization, cardiac surgery, surgery organ transplantation and dialysis.
Celite ACT cartridges have increased numbers of values outside the accepted allowable error.
- 2010-11-17TerminatedOther
i-STAT ACT Celite Cartridges in vitro diagnostic test used to monitor moderate and high-level heparin therapy through analysis of arterial and venous whole blood samples.
Certain lots of i-STAT Celite ACT and Kaolin ACT cartridges may be difficult to fill or will not fill when attempting to transfer blood to the sample entry port of the cartridge.
- 2010-11-17TerminatedOther
i-STAT ACT Kaolin Cartridges in vitro diagnostic test which uses fresh whole blood to monitor high-dose heparin anticoagulation frequently associated with cardiovascular surgery.
Certain lots of i-STAT Celite ACT and Kaolin ACT cartridges may be difficult to fill or will not fill when attempting to transfer blood to the sample entry port of the cartridge.
- 2010-02-23TerminatedLabeling False and Misleading
Abbott i-STAT ACT Celite Cartridges. In vitro diagnostic test used to monitor moderate and high-level heparin therapy through analysis of arterial and venous whole blood samples.
Labeling discrepancy: The manual instruction state that the line should be flushed with 5 mL of saline and the first 5 mL of blood or six dead space volumes should be discarded. The Cartridge Test Information sheets that it should be 2 mL of blood - which is incorrect.
- 2010-02-23TerminatedLabeling False and Misleading
Abbott i-STAT ACT Kaolin Cartridges. In vitro diagnostic test which uses fresh whole blood to monitor high-dose heparin anticoagulation frequently associated with cardiovascular surgery.
Labeling discrepancy: The manual instruction state that the line should be flushed with 5 mL of saline and the first 5 mL of blood or six dead space volumes should be discarded. The Cartridge Test Information sheets that it should be 2 mL of blood - which is incorrect.
- 2009-08-21TerminatedEmployee error
Hemochron Jr. ACT- LR Assay (JACT- LR); ITC Catalogue/Code Number: JACTLR 45 Cuvettes; For Performance on the HEMOCHROM Whole Blood Microagulation Systems; International Technidyne Corp., Edison, NJ 08820. The HEMOCHRON Jr. ACT-LR is a quantitative assay for monitoring heparin anticoagulation during various medical procedures. The ACT-LR demonstrated linear correlation to the anticoagulation effects of heparin up to 2.5 unit/ml of blood. It is intended for use in monitoring low to moderate heparin doses frequently associated with procedures such as cardiac catheterization, Extracorporeal Membrane Oxygenation (ECMO) Hemodialysis, and Percutaneous Transluminal Coronary Angioplasty.
One lot of ACT-LR was released when one finished good testing criteria acceptance limit did not meet acceptance criteria.
- 2005-08-23TerminatedOther
Hemochron Jr. Whole Blood Microcoagulation system Low Range Activated Clotting Time. ACT-LR Cuvettes. In vitro diagnostic use, non-sterile, Packaged in individual foil pouches. 45 foil pouches per shelf carton box. Mfg. by International Technidyne Corp, Edison, NJ 08820.
Validation had been initiated for a molded component of the finished device but not completed. Also, the device did not meet mean clotting time using Normal Donor Blood as media.
- 2005-06-21TerminatedOther
i-STAT Celite ACT Cartridge. ACT, activated clotting time, celite activated clotting time test.
Misidentification of Celite ACT cartridge as kaolin ACT Cartridge in the analyzer.
Monitor activated whole blood clotting time automatically