Skip to main content
IYXClass 1

Camera, Scintillation (Gamma)

FDA adverse event reports and recall history for camera, scintillation (gamma) (product code IYX), from the public MAUDE/AEMS corpus and the live FDA recall database.

Total reports
404
Deaths
5
Injuries
51
Malfunctions
287

Reports per year

04
05
06
07
08
09
10
11
12
13
14
15
16
18
22

Source: FDA adverse event reports by year received, 20042022. Reporting paused during the 2026 MAUDE-to-AEMS transition and has since resumed.

Recent recalls

  • 2026-01-09Open, ClassifiedPackage design/selection

    SMV DSX New Line, System, Tomography, Computed, Emission

    GE HealthCare has become aware that certain Nuclear Medicine systems that are past the End of Guaranteed Service (herein referred to as Impacted Systems and listed in the Affected Product Details section of this letter) could have been transported or relocated without adequate detector support. This could result in excessive stress being applied to the detector mounting mechanisms, compromising their integrity. If this occurs, it can potentially result in a detector fall and lead to life-threatening bodily injury. There have been no reports of detector falls or injuries as a result of this potential issue. The Impacted Systems affected by this notice are those that have not been manufactured for several years. GE HealthCare has previously communicated End of Guaranteed Service for these Impacted Systems.

  • 2026-01-09Open, ClassifiedPackage design/selection

    SMV BodyTrack, System, Tomography, Computed, Emission

    GE HealthCare has become aware that certain Nuclear Medicine systems that are past the End of Guaranteed Service (herein referred to as Impacted Systems and listed in the Affected Product Details section of this letter) could have been transported or relocated without adequate detector support. This could result in excessive stress being applied to the detector mounting mechanisms, compromising their integrity. If this occurs, it can potentially result in a detector fall and lead to life-threatening bodily injury. There have been no reports of detector falls or injuries as a result of this potential issue. The Impacted Systems affected by this notice are those that have not been manufactured for several years. GE HealthCare has previously communicated End of Guaranteed Service for these Impacted Systems.

  • 2004-08-24TerminatedOther

    SMV FX-40 Nuclear Camera

    The detector head of a FX-80 Nuclear camera may fall from the gantry. Three potential causes have been determined. (1) A ball nut in the detector's radial drive assembly can back out of the bearing block that contains it. (2) Misalignment of the radial drive assembly. (3) Mounting bolts on the radial drive assembly may become loose, fail, or back out.

  • 2004-08-24TerminatedOther

    SMV FX-80 Nuclear Camera

    The detector head of a FX-80 Nuclear camera may fall from the gantry. Three potential causes have been determined. (1) A ball nut in the detector's radial drive assembly can back out of the bearing block that contains it. (2) Misalignment of the radial drive assembly. (3) Mounting bolts on the radial drive assembly may become loose, fail, or back out.

  • 2004-02-10TerminatedOther

    CDLCAM, First-Pass Radionuclide Angiography Camera System, Model 70-500101, with operating Software Version B1A, marketed by CDL Medical Tech.

    Due to limitations in the operating software, the acquired scan may not be processed properly.

  • 2003-03-06TerminatedOther

    Integrated Orbiter Single Detector General Purpose Gamma Camera System; Siemens Medical Systems, Inc., Nuclear Medicine Group, 2501 North Barrington Road, Hoffman Estates, IL 60195-5203

    Unintended yoke rotational motion.

  • TerminatedDevice Design

    e.cam and Symbia E gamma camera systems with patient beds To detect or image the distribution of radionuclides in the body or organ, using the following techniques: planar imaging, whole body imaging, tomographic imaging for isotopes with energies up to 588 keV.

    "We have received reports of patients hair being caught in the e.cam and Symbia E patient bed up/down drive. The purpose of this letter is to remind users of the patient positioning instructions for your e.cam or Symbia E system and to inform you of an update that will be performed by your local Siemens service representative."

Monitor camera, scintillation (gamma) automatically

DeviceWatch watches FDA adverse events and recalls for the products you care about, summarizes clinical narratives with AI and alerts you when a safety signal emerges.