Table, Radiographic, Tilting

FDA adverse event reports and recall history for table, radiographic, tilting (product code IXR), from the public MAUDE corpus and the live FDA recall database.

Total reports
762
Deaths
1
Injuries
21
Malfunctions
726

Reports per year

11
12
13
14
15
16
17
18
19
20
21
22
23
24
26

Source: FDA adverse event reports by year received, 2011–2026. Reporting paused twice in 2026 during FDA reporting-system changes and has since resumed.

Recent recalls

  • 2025-11-07Open, ClassifiedProcess control

    Brand Name: Sonesta Product Name: 6210 Model/Catalog Number: 0120-LA120-03 Software Version: N/A Product Description: Sonesta 6210 - Procedure table designed for full fluoroscopic imaging of the urinary tract during video Urodynamics procedures. Component: N/A

    Video fluoroscopy table may contain inadequate weld on backrest bracket resulting in backrest dropping.

  • 2018-05-03TerminatedNonconforming Material/Component

    708033 URODiagnost As a multifunctional universal imaging application system, General RJF, Fluoroscopy, Radiography and Angiography can be Performed along with more specialized interventional applications on human patients.

    The fixation of the upper and lower tilt actuator, of the MD-Eleva system might break off and the table will start to rotate from 0 to + 90 I- 90 degree with high speed. This rotating movement cannot be stopped by the user.

  • 2018-02-23TerminatedDevice Design

    Foot Controls impacted for the following devices: OAKWORKS Medical CFPM 300 Imaging Table OAKWORKS Medical CFPM 301 Imaging Table OAKWORKS Medical CFPM 400 Imaging Table OAKWORKS Medical CFPM 401 Imaging Table OAKWORKS Medical CFPMB 301 Bariatric Imaging Table OAKWORKS Medical CFUR 301 Urology Table OAKWORKS Medical CFUR 401 Urology Table OAKWORKS Medical CFLU 401 Lithotripsy/Urology Table

    The foot control used on the OAKWORKS Inc., CFPM300, CFPM301, CFPM400, CFPM401, CFPMB301, CFUR301, CFUR401 and CFLU401 Imaging Tables can become lodged under the base or under the column of the table.

  • 2017-05-22TerminatedDevice Design

    Table Patient Step on RFX/SFX, Legacy, and Precision 500D systems

    Reported incidents of a patient step detaching from the table. A fall from a patient step detaching while in use could result in an injury to a patient or operator.

  • 2016-04-28TerminatedDevice Design

    X-Ray Diagnostic Table, Model No. YSF-300 Use in combination with an X-ray high voltage generator, an X-ray tube unit, an Image intensifier and X-ray television unit, this table is applied for the following X-ray examinations: -X-ray T.V. fluoroscopy -Spot-filming -Bucky radiography

    Report of unintentional movement of table to reverse tilting.

  • 2012-08-15TerminatedEquipment maintenance

    Philips Easy Diagnost Classic-Stationary x-ray system Catalog Numbers: 70642, 70643, 706030, 706031, 706032 Stationary x-ray system, Universal RF system for general use.

    Inclination switch in the stand may have been mounted incorrectly, as a result, the switch could not stop the tilting movement of the table base due tol hardware or software errors.

  • 2012-06-18TerminatedDevice Design

    Philips Easy Diagnost Product Usage: Stationary Fluoroscopic system

    If a lead ruler is not positioned in the same plane as the anatomical image detail to be measured, measured object distances (using the ruler) can be wrong by a corresponding factor. If, additionally, the measurement tool is not used to check the ruler, or is used in the right way (ie: calibration), such calibration error is not detected. As a result of this, a surgical intervention may be execut

  • 2011-04-13TerminatedOther

    Rapid Response H.U.T. (Head Up Tilt) Table. Model 1017. Powered electrophysiology tilt table. Table can tilt -15 degrees to 90 degrees (Trendelenburg). Medical Positioning Incorporated.800-593-3246. Used in clinical and hospital settings by trained radiologists.

    The tilt tables work intermittently and some have become stuck in an inclined or reclined position during procedures.

  • 2011-04-13TerminatedOther

    Rapid Response HUT (Head Up Tilt) Table. Model 1117. Powered electrophysiology tilt table with single drop section. Table that can tilt -15 degrees to 90 degrees (Trendelenburg). Medical Positioning Incorporated.800-593-3246. Used in clinical and hospital settings by trained radiologists.

    The tilt tables work intermittently and some have become stuck in an inclined or reclined position during procedures.

  • 2011-04-13TerminatedOther

    Rapid Response HUT (Head Up Tilt) Table. Model 1217. Powered electrophysiology tilt table with dual 2 way drop section. Table that can tilt -15 degree to 90 degree (Trendelenburg). Medical Positioning Incorporated. 800-593-3246. Used in clinical and hospital settings by trained radiologists.

    The tilt tables work intermittently and some have become stuck in an inclined or reclined position during procedures.

Monitor table, radiographic, tilting automatically