IPFClass 2

Stimulator, Muscle, Powered

FDA adverse event reports and recall history for stimulator, muscle, powered (product code IPF), from the public MAUDE corpus and the live FDA recall database.

Total reports
678
Deaths
1
Injuries
347
Malfunctions
181

Reports per year

12
13
14
15
16
17
18
19
20
21
22
23
24
25
26

Source: FDA adverse event reports by year received, 2012–2026. Reporting paused twice in 2026 during FDA reporting-system changes and has since resumed.

Recent recalls

  • 2023-12-07Open, ClassifiedError in labeling

    Multi-Mode Stimulator, Transcutaneous Electrical Nerve Stimulation

    The instruction manuals that were included with the Multi-Mode Stimulators distributed from 2018 to 2023 did not contain all of the appropriate warnings and contraindications.

  • 2014-06-26TerminatedComponent design/selection

    IF 8000; 1/F Interferential Electrical Stimulation Device; NMES (neuromuscular electrical stimulation) mode. Designed for use in physical therapy, rehabilitation, and pain relief applications.

    Zynex notified customers that a malfunction in the IF 8000 can result in the device ceasing to operate, and in some instances,overheating and becoming hot to the touch.

  • 2012-03-01TerminatedNonconforming Material/Component

    Perfector Product Usage: Muscle stimulation

    Wires do not meet performance standards under 21 CFR 898 and have unprotected electrode configurations. Additionally, devices were sold/distributed without 510(k) or PMA

  • 2012-03-01TerminatedNonconforming Material/Component

    Ion Magnum Product Usage: Muscle stimulation

    Wires do not meet performance standards under 21 CFR 898 and have unprotected electrode configurations. Additionally, devices were sold/distributed without 510(k) or PMA

  • 2012-03-01TerminatedNonconforming Material/Component

    Arasys Product Usage: Muscle stimulation

    Wires do not meet performance standards under 21 CFR 898 and have unprotected electrode configurations. Additionally, devices were sold/distributed without 510(k) or PMA

  • 2011-07-25TerminatedOther

    eSwallow Multi-Program Dysphagia Therapy Test unit Intended Use: Powered Muscle Stimulator for treatment of dysphagia.

    It was discovered that the firm was distributing medical devices without FDA approval.

  • 2010-11-08TerminatedOther

    The device is labeled in part: " RS Medical RS-4i Stimulator". The device is sold in a kit that includes a carrying case, connector cables, pads (electrodes), battery charger, patient document, instructional DVD, return mail bag, and the operation manual. This device is used with cables and electrodes that are placed on skin in the treatment area, and allow an electrical micro-current to relieve pain. The device requires a prescription from a physician. It is programmed by an RS medical employee (or Account Manager) to the physician's specific treatment plan for each patient. The patient is given instructions on how to utilize the device (proper electrode placement). Powered MUSCLE Stimulation indications for use including: 1) Relax muscle spasm. 2) Prevention or retardation of disuse atrophy. 3) Maintain or increase range of motion. 4) Increase local blood circulation. 5) Re-educate muscle. 6) Immediate post-surgical stimulation of calf muscles to prevent venous thrombosis. INTERFERENTIAL Stimulation indications for use including: 1) Relieve acute pain. 2) Relieve and manage chronic pain.

    The charge current is leaking through two Diodes, which are supposed to block the reverse current, when the device is warm during the main battery charge operation, it then causes the lithium battery to swell around two years of use and it causes the device to be inoperable.

Monitor stimulator, muscle, powered automatically