HXCClass 1

Wrench

FDA adverse event reports and recall history for wrench (product code HXC), from the public MAUDE corpus and the live FDA recall database.

Total reports
1,583
Deaths
1
Injuries
75
Malfunctions
1,501

Reports per year

12
13
14
15
16
17
18
19
20
21
22
23
24
25
26

Source: FDA adverse event reports by year received, 2012–2026. Reporting paused twice in 2026 during FDA reporting-system changes and has since resumed.

Recent recalls

  • 2016-05-10TerminatedDevice Design

    Axial Torque Limiting Driver (1st generation) Product Usage: The Bradshaw Medical Axial Torque Limiting Driver is a reusable surgical instrument designed to limit the magnitude of applied (input) torque transferred to an external (output) device or fastener in the clockwise direction. The device is a non-adjustable mechanical click style hand torque tool which presents an audible and tactile click when the maximum desired torque is reached.

    A component failure could cause a situation where the applied torque was significantly higher than the calibrated torque setting.

  • 2016-02-11TerminatedComponent design/selection

    Firebird Spinal Fixation System Torque Limiting Handle (PN 52-1512) Intended for posterior, non-cervical pedicle, and non-pedicle fixation (T1-S2/llium).

    There is a possibility that the device may deliver a torque value less than the required setting after initial sterilization. In worst case, the unexpected drop in torque value may lead to the spinal construct loosening and requiring corrective surgical intervention.

  • 2015-08-03TerminatedLabeling design

    S4C Occiput Torque Wrench F/Set Screw; used to tighten the S4 Cervical Spinal System clamping screws with a defined torque 2.8 Nm for tightening the clamping screw in the screw head/hook head/occipital plate/transverse connector and other connectors.

    A FW103R torque wrench that was improperly reassembled after reprocessing caused a screw to break during implantation due to too much torque. The firm did not include instructions for reassembly after reprocessing.

  • 2015-04-20TerminatedComponent design/selection

    Lineum HF Torque Handle Limit (Lineum) Model Number 14-525035 P_roduct Usage: Designed to facilitate reconstruction of the cervical and upper thoracic spine using bones screws, locking plugs, and various types of rods, hooks, and lateral connectors.

    Biomet is recalling the Lineum HF Torque Handle Limit (Lineum) and Torque Limiting Handle (Aspen/ Alpine) due to the supplier withdrawing it from the market for component updates or reconfiguration.

  • 2015-04-20TerminatedComponent design/selection

    Torque Limiting Handle (Aspen/ Alpine) Model Number 6200-1109 Product Usage: Provides posterior fixation in the non-cervical spine with an interspinous fixation device.

    Biomet is recalling the Lineum HF Torque Handle Limit (Lineum) and Torque Limiting Handle (Aspen/ Alpine) due to the supplier withdrawing it from the market for component updates or reconfiguration.

  • 2013-01-16TerminatedDevice Design

    DePuy Spine EXPEDIUM Offset Torque Wrench Product Code 2797-29-510 The device is intended for use during the final tightening of an Expedium Offset Spinal Construct.

    A component within the handle of the Expedium Offset Torque Wrench is prematurely wearing, potentially resulting in the instrument recording torque values outside of the specification.

  • 2009-03-04TerminatedProcess control

    Zimmer Silhouette Axial Torque Handle, Zimmer Spine, Inc., Minneapolis, MN; REF 7010-0151-01. Reusable instrument that is used to apply the appropriate torque to the lock nut that is part of the Silhouette Spinal Fixation System.

    Some of the torque wrenches apply less than the minimum torque to the screw locking cap when the torque indicators are aligned as described in the surgical technique.

  • Open, ClassifiedNonconforming Material/Component

    Metalogix Slotted 90 Tubular Wrench x 10mm REF 900104 LOT A29618A

    Due to manufacturing processing error, wrench causing stripping when torqueing nuts.

Monitor wrench automatically