Arthroscope
FDA adverse event reports and recall history for arthroscope (product code HRX), from the public MAUDE corpus and the live FDA recall database.
- Total reports
- 25,912
- Deaths
- 36
- Injuries
- 2,736
- Malfunctions
- 22,569
Reports per year
Source: FDA adverse event reports by year received, 2012–2026. Reporting paused twice in 2026 during FDA reporting-system changes and has since resumed.
Recent recalls
- 2025-03-25Open, ClassifiedUnder Investigation by firm
Medline procedure kits labeled as: 1) C SCOPE DISPOSABLE KIT, Pack Number 613034700, 2) C SCOPE DISPOSABLE KIT, Pack Number 613034702
Medical convenience kits contain plastic syringes affected by the FDA Safety Alert issued on March 19, 2024. Leaks, breakage, and/other quality issues have been identified that may pose a risk to patient health.
- 2024-11-25Open, ClassifiedUnder Investigation by firm
4.5 x 180 mm REF 28208BKS Aggressive Cutter, sterile, 6x 3.5 x 70 mm REF 28206CBS Full Radius Resector, sterile, 6x 5.5 x 120 mm REF 28205NDS Aggr. Pro Line Shaver Blade, sterile, 6x 5.5 x 120 mm REF 20205FDS Round Burr, sterile, 6x 6.5 x 120 mm REF 28205HES, Aggressive Barrel Burr, sterile, 6x 4.2 x 120 mm REF 28205GDS Finish Barrel Burr, sterile, 6x 5.5 x 180 mm REF 28208IDS Semi Hooded Barrel Burr, sterile, 6x 5.5 x 120 mm REF 28205HDS Aggressive Barrel Burr, sterile, 6x
Due to holes detected in the inner barrier system that may compromise the sterility of the affected products.
- 2024-09-06Open, ClassifiedUnder Investigation by firm
Medline Convenience kits labeled as: 1) C SCOPE DISPOSABLE KIT, Pack Code 613034700; 2) C SCOPE DISPOSABLE KIT, Pack Code 613034701; 3) C SCOPE DISPOSABLE KIT, Pack Code 613034702
Medical convenience kits contain plastic syringes affected by the FDA Safety Alert issued on March 19, 2024. Leaks, breakage, and/ other quality issues have been identified that may pose a risk to patient health.
- 2024-07-01Open, ClassifiedProcess control
WOM Tube Set for lrrlgatlon, single-use- Intended to transport irrigation fluid to the patient in endoscopic surgeries. Distr. by Endoscopy Smith & Nephew Inc. REF Numbers: T0449-01
Incorrect transponder data was written on the RFID tags triggers the error message E03, Tube Set lnvalid, may result in a delay of surgery
- 2020-07-24Open, ClassifiedProcess design
Smith & Nephew T-F1X0 RCG Drill Pac, 2 mm Drill & (2) Sleeves - Product Usage: indicated for use in surgical arthroscopic rotator cuff repair procedures. REF/ Catalog Number : 014771
The T-Fix sterile package contains only one sleeve instead of two, The device will not perform as intended for the second bone tunnel due to the absence of thesleeve
- 2018-05-25TerminatedOther
MicroAire SmartRelease Endoscopic System, Endoscopic Carpal Tunnel Release, SmartRelease Handpiece, containing IFU rev. D The MicroAire Carpal Tunnel Release System is for use in patients diagnosed with carpal tunnel syndrome that is not associated with, or secondary to, any other known pathology (i.e., idiopathic carpal tunnel syndrome). Preoperative x-rays of the wrist, including a carpal tunnel view, are recommended to aid in the diagnosis of associated pathology (i.e., calcific tendonitis, fracture of the hook of the hamate). This device is indicated for releasing the transverse carpal ligament (flexor retinaculum).
The Instructions for Use (IFU) is incorrect with regards to sterilization parameters and must be replaced.
- 2016-05-26TerminatedEquipment maintenance
Various trauma and sports medicine instruments and implants. Arthroscope.
Insufficient seal strength on sterile barrier packaging. The seal could be jeopardized causing the sterile barrier to be compromised and the product could become nonsterile. If the product becomes non-sterile and is used or implanted, it may lead to an infection.
- 2016-02-09TerminatedProcess control
Reuseable rotary blade/abrader, product number 899751305. The round burr is an attachment or accessory to the air-powered device intended for use during surgical procedures to cut hard tissue or bone and soft tissue. General hospital and plastic surgery use.
Weak weld in the reusable rotary blade/abrader (burr) may result in inner part breaks at the distal or proximal end making the product dysfunctional.
- 2016-02-09TerminatedProcess control
Reuseable rotary blade/abrader, product number 899751504. The oval burr laterally hooded is an attachment or accessory to the air-powered device intended for use during surgical procedures to cut hard tissue or bone and soft tissue. General hospital and plastic surgery use.
Weak weld in the reusable rotary blade/abrader (burr) may result in inner part breaks at the distal or proximal end making the product dysfunctional.
- 2016-02-09TerminatedProcess control
Reuseable rotary blade/abrader, product number 899751514. The oval burr frontally hooded is an attachment or accessory to the air-powered device intended for use during surgical procedures to cut hard tissue or bone and soft tissue. General hospital and plastic surgery use.
Weak weld in the reusable rotary blade/abrader (burr) may result in inner part breaks at the distal or proximal end making the product dysfunctional.
Monitor arthroscope automatically