FDA adverse event reports and recall history for bur, surgical, general & plastic surgery (product code GFF), from the public MAUDE corpus and the live FDA recall database.

Total reports
2,120
Deaths
0
Injuries
173
Malfunctions
1,921

Reports per year

12
13
14
15
16
17
18
19
20
21
22
23
24
25
26

Source: FDA adverse event reports by year received, 2012–2026. Reporting paused twice in 2026 during FDA reporting-system changes and has since resumed.

Recent recalls

  • 2016-05-31TerminatedMixed-up of materials/components

    Hip Preservation System Signature Series PreBent Burs under the following labels: 1) PreBent Spherical Bur, 5.5mm x 19cm Catalog Number HPS-HB11, 2) PreBent Polishing Bur, 5.5mm x 19cm Catalog Number HPS-HB12 and 3) PreBent Oval Bur, 6.0mm x 19cm Catalog Number HPS-HB13 The ConMed Hip Preservation System Signature Series is intended to be used for resection of osseous tissue (bone) in arthroscopic and endoscopic surgical procedures

    Metal shavings released from burs during use are due to contact between the bur and the hood of the PreBent Bur assembly. During the manufacturing process an assembly error occurred which caused inadvertent mixing of two sizes of bearings.

  • 2015-07-24TerminatedOther

    Medical Device Exchange 2.15MMX22MM Fluted Spiral Router for CRANI-A; Pouch, Tyvek/Mylar, Sterile, Single Use Only; OEM Catalog number A-CRN-S; EXP (repackager), Anspach (OEM) Bur, surgical, general & plastic surgery

    EXP did not register as a medical device establishment, list the devices being recalled, or establish its own quality system and instead relied on the fact that its vendors were registered and had their own quality systems.

  • 2014-01-27TerminatedPending

    Anspach REF: TURQ-434-4 Twist Drill for 1.5mm x 4mm screw. Rx only Single use Sterile bone cutting burs.

    Cutter was longer than was stated on the label

  • 2014-01-06TerminatedUnknown/Undetermined by firm

    Anspach B-Blue-S 11.25 cm attachment and Anspach B-Green Standard Craniotome. Cutting and shaping bone.

    Anspach was contacted by a hospital to inform Anspach that a Blackmax motor had been used in a case where the patient was diagnosed with Creutzfeldt-Jacob Disease (CJD).

  • 2013-07-01TerminatedPackaging process control

    - Acorn Bur, Long, For Use With TPS Universal Drill, Long "AM" Attachment Head: 7.5mm Dia. x 9.5mm Length Ref. 5130-30-75 Lot 122665 - Cannulated Drill Bit, for 3.0mm Cannulated Screws, 1.2mm Cannulation, Quick Coupling 2.0mm x 150mm Ref. 310.221 Lot 122289 - Drill Bit, For Modular Hand System, Quick Coupling 2.8mm x 165mm Ref. 310.288 Lot 122322 - Drill Bit, Quick Coupling (Gold) 2.5mm Ref. DB-2.5 Lot 122289, 122322 - Egg Micro Bur, 10 Flute, Stainless Steel 4.0mm Ref. 1608-2-35 Lot 122429, 122347 - Hall Micro Bur, Oval, Long, 8-Flute, Carbide 4.0mm x 8.0mm Ref. 5092-136 Lot 123353 - Micro Bur, Round, Stainless Steel 3.2mm Ref. 1608-2-11 Lot 122447, 122347 - Oval Bur, Fast Cutting, 8-Flutes, Carbide, 44.5mm Total Length, 18.6mm Exposure 4.0mm x 7.9mm Ref. 227-10-62 Lot 122411 - Oval Bur, Solid, 8-Flute, Medium, Head Length: 7.7mm, Carbide 4.0mm x 48mm Ref. 5300-10-901 Lot 122647 - Oval Cutting Carbide Bur, Medium, (8-Flute) 4.0mm Ref. 5091-136 Lot 123353, 122454 - Round Bur, Medium, Solid 8-Flute, Carbide 4.0mm x 48.3mm Ref. 5300-10-511 Lot 122665 - Round Bur, Micro, 8-Flute, Exposure: 28.2mm Stainless Steel 2.4mm x 54mm Ref. 1608-2-9 Lot 122447 - Twist Drill, Quick Coupling 110mm 2.5mm Ref. 310.25 Lot 122289, 122322 - Wire Pass Drill Bit 1.5mm Ref. 1608-2-59 Lot 122511 Surgical instrument motors and accessories/attachments

    The seal which maintains a sterile barrier for reprocessed medical devices became compromised to the point where product may fall out of the pouch.

  • 2009-01-13TerminatedPackaging process control

    Burrs Model #'s: ANSL-3SB ANSL-5D ANSQD11-4OVDC HAL5056-118 HAL5056-166 HAL5091-106 HAL5091-112 HAL5091-122 HAL5091-125 HAL5091-136 HAL5091-144 HAL5091-164 HAL5092-120 HAL5092-168 HAL5092-170 KOM04-D0139 LIN5091-101 LIN5091-102 LIN5091-142 LIN5092-132 LIN5092-160 MED874-447 MICZB-228 MICZB-232 MID14CY50 MID14MH30D MIDG6-450 MIDG8-130 MIDMC254 STR1607-2-35 STR1608-6-137 STR1608-6-141 STR1608-6-149 STR277-10-62 STR5120-10-40 STR5120-10-50 STR5120-71-48 STR5300-10-511 STR5300-10-513 STR5300-10-903 STR5300-20-513 STR5300-30-903 XOM31-55641 ZIM5056-116 ZIM5056-117 ZIM5056-118 ZIM5056-125 ZIM5056-140 ZIM5056-150 ZIM5056-159 ZIM5056-161 ZIM5056-162 ZIM5056-164 and ZIM5056-167 Surgical instruments motors and accessories are AC-powered, battery-powered, or air-powered devices intended for use during surgical procedures to provide power to operate various accessories or attachments to cut hard tissue or bone and soft tissue.

    SteriMed, Inc is conducting a product removal of a small group of devices individually packaged and sealed within a pouch. The removal is being conducted because the possibility exists that some of the pouches were not properly sealed on one end. A breach in packaging seal or a failure in packaging integrity has the possibility of risk to the patient in terms of transmitting organisms capable

  • 2008-04-08TerminatedPackaging process control

    ConMed Linvatec, Ultrapower Burs, Linvatec Corporation, Largo, FL 33773

    Compromised sterility: ConMed Linvatec medical devices packaged within a certain Peel Pouch Sterile Package may have compromised sterility due to an improper seal.

  • 2004-07-20TerminatedOther

    Product is a surgical nasal/sinus surgical device labeled as a RAD Frontal Finesse Bur, Reference Number 18-83070

    The curve in the shaft of the bur was only 15 degrees not the labeled 40 degrees.

  • TerminatedProcess control

    Darco STERILE HEADED DRILL BIT 4.4MM , Part Number 777S06514

    The firm discovered a lack of adequate documentation confirming sterility on certain products.

  • TerminatedUnder Investigation by firm

    BRASSELER KM166-310-35 Twist Drill Quick Connect Diameter 3.5 mm, Total Length 112mm, Effective Length, 86mm - Product Usage: Twist drill intended use: to drill into bone in hip or knee surgeries.

    One lot of 3.5 mm twist drills were incorrectly laser etched as 2.5 mm the shaft of the device.

Monitor bur, surgical, general & plastic surgery automatically

DeviceWatch watches FDA adverse events and recalls for the products you care about, summarizes clinical narratives with AI and alerts you when a safety signal emerges.