Biopsy Needle
FDA adverse event reports and recall history for biopsy needle (product code FCG), from the public MAUDE corpus and the live FDA recall database.
- Total reports
- 4,980
- Deaths
- 27
- Injuries
- 1,022
- Malfunctions
- 3,909
Reports per year
Source: FDA adverse event reports by year received, 2012–2026. Reporting paused twice in 2026 during FDA reporting-system changes and has since resumed.
Recent recalls
- 2024-09-20Open, ClassifiedPackaging change control
BARD MAGNUM Disposable Core Tissue Biopsy Needle REF: MN1410 MN 1420 MN1610 MN1616 MN1820 MN2010 The Magnum Biopsy System (instrument and needles) is intended for use in obtaining biopsies from soft tissues such as liver, kidney, prostate, breast, spleen, lymph nodes and various soft tissue tumors.
Due to possible packaging damage (indentations/cuts) cause by manufacturing process. As a result of the packaging damage, may cause the sterile barrier to be compromised.
- 2024-09-06Open, ClassifiedUnder Investigation by firm
Medline Convenience kits labeled as: 1) NHP BREAST BIOPSY PACK, Pack Number DYNJ17400B; 2) BREAST BIOPSY TRAY, Pack Number DYNJ32049A ; 3) BREAST BIOPSY PACK, Pack Number DYNJ44987G ; 4) BREAST BIOPSY PACK, Pack Number DYNJ66288
Medical convenience kits contain plastic syringes affected by the FDA Safety Alert issued on March 19, 2024. Leaks, breakage, and/ other quality issues have been identified that may pose a risk to patient health.
- 2024-05-16Open, ClassifiedNonconforming Material/Component
EchoTip Ultra HD Endoscopic Ultrasound Access Needle, ECHO-HD-19-A, G52012
Devices may contain elevated levels of bacterial endotoxin.
- 2024-05-16Open, ClassifiedNonconforming Material/Component
EchoTip Ultra Endoscopic Ultrasound Access Needle, ECHO-19, G31520
Devices may contain elevated levels of bacterial endotoxin.
- 2023-05-19Open, ClassifiedEmployee error
ViziShot 2 Single Use Aspiration Needle, 21G- To be used with ultrasound endoscopes for ultrasound guided fine needle aspiration (FNA) of submucosal and extramural lesions of the tracheobronchial tree and the gastrointestinal tract. Model: NA-U401SX-4021, NA-U401SX-4021-A
Product non-conformance pertaining to the angle of the needle does not meet manufacturing specifications and remained unbent, resulting to slight resistance experienced during needle advancement and retraction.
- 2023-05-19Open, ClassifiedEmployee error
To be used with ultrasound endoscopes for ultrasound guided fine needle aspiration (FNA) of submucosal and extramural lesions of the tracheobronchial tree and the gastrointestinal tract Models: NA-U401SX-4022, NA-U401SX-4022-A
Product non-conformance pertaining to the angle of the needle does not meet manufacturing specifications and remained unbent, resulting to slight resistance experienced during needle advancement and retraction.
- 2022-08-26Open, ClassifiedEnvironmental control
MERIT MEDICAL SYSTEMS Temno Soft Tissue Biopsy Device Temno 14 Gauge 6 cm Length Beveled Sharp Tip Model Number: T146
Facility Temperature excursions (from June 2021-August 2021) prior to delivery; exposure to higher temperatures may have impacted product effectiveness. All lots received between 06/01/21-9/30/21.
- 2020-08-05Open, ClassifiedUnder Investigation by firm
Beacon EUS Access System Preloaded Access 90degree Needle sterile, single-use, endoscopic ultrasound device consisting of a sharp stylet and an 18.5-gauge, echo-enhanced, tip-shaped, nitinol cannula intended to pierce tissue and then act as an access channel to facilitate guidewire placement to locations of the gastrointestinal tract.
This voluntary recall is being conducted following three customer reports of the device cannula detaching during a procedure. In one case, the detached cannula was not retrieved during the procedure. Potential risks associated with a detached cannula include delay in treatment, biliary leak, pain and retained device fragments.
- 2020-08-05Open, ClassifiedUnder Investigation by firm
Beacon EUS Access System Preloaded Access 135degree Needle sterile, single-use, endoscopic ultrasound device consisting of a sharp stylet and an 18.5-gauge, echo-enhanced, tip-shaped, nitinol cannula intended to pierce tissue and then act as an access channel to facilitate guidewire placement to locations of the gastrointestinal tract.
This voluntary recall is being conducted following three customer reports of the device cannula detaching during a procedure. In one case, the detached cannula was not retrieved during the procedure. Potential risks associated with a detached cannula include delay in treatment, biliary leak, pain and retained device fragments.
- 2017-02-28TerminatedNonconforming Material/Component
BNX Fine Need Aspiration System (19GA); Material/Part #: DSN-19-01
Handle may break during use.
Monitor biopsy needle automatically
DeviceWatch watches FDA adverse events and recalls for the products you care about, summarizes clinical narratives with AI and alerts you when a safety signal emerges.