Skip to main content
DXCClass 2

Clamp, Vascular

FDA adverse event reports and recall history for clamp, vascular (product code DXC), from the public MAUDE corpus and the live FDA recall database.

Total reports
13,157
Deaths
78
Injuries
1,395
Malfunctions
11,590

Reports per year

12
13
14
15
16
17
18
19
20
21
22
23
24
25
26

Source: FDA adverse event reports by year received, 2012–2026. Reporting paused twice in 2026 during FDA reporting-system changes and has since resumed.

Recent recalls

  • 2025-09-26Open, ClassifiedNonconforming Material/Component

    JUNCTIONAL EMERGENCY TREATMENT TOOL (JETT), REF: 30-0088, a component inside kits: KIT, TCCC Training- Complete (Modules 1-3), REF: 85-0550; KIT, TCCC MODULE ONE - SKILLS, REF: 85-0519; KIT, MULTI MISSION EXPEDITIONARY RESPONSE - MMERK, REF: 85-2420; KIT, TCCC SKILLS/IFAK COMBO, REF: 85-0740, KIT, TCCC/TECC MODULE ONE SKILLS REFILL, REF: 85-1900

    Device used for unilateral or bilateral occlusion of blood flow to the lower limbs has a potential manufacturing defect that may compromise the structural integrity of the device and device performance during use.

  • 2025-09-18Open, ClassifiedUnder Investigation by firm

    Heartstring III Proximal Seal System. Intravascular anastomosis occluder.

    Three failure modes have been identified: failure of the Heartstring Seal to load, failure of the Heartstring Seal to deploy into the aortotomy, and failure of the deployed Heartstring Seal to provide adequate hemostasis.

  • 2025-09-18Open, ClassifiedUnder Investigation by firm

    Heartstring III Proximal Seal System, 3.8 MM. Intravascular anastomosis occluder.

    Three failure modes have been identified: failure of the Heartstring Seal to load, failure of the Heartstring Seal to deploy into the aortotomy, and failure of the deployed Heartstring Seal to provide adequate hemostasis.

  • 2025-09-18Open, ClassifiedUnder Investigation by firm

    Heartstring III Proximal Seal System, 4.3 MM. Intravascular anastomosis occluder.

    Three failure modes have been identified: failure of the Heartstring Seal to load, failure of the Heartstring Seal to deploy into the aortotomy, and failure of the deployed Heartstring Seal to provide adequate hemostasis.

  • 2024-04-12Open, ClassifiedUnder Investigation by firm

    Surgical Tools and Cardiovascular Specialty marketing brochures, Reference numbers: US-AS18-210002 Surgical Tools Brochure 2021, US-AS18-210004 Surgical Tools Website v1, and US-AS46-230002 CV Specialty Brochure US version which affect: Flo-Rester Disposable Internal Vessel Occluder, Item Numbers: a) 50100, b) 50125, c) 50150, d) 50175, e) 50200, f) 50225, g) 50250, h) 50275, i) 50300, j) 50350, k) 50400, l) 50450BIOS, m) 60100, n) 60125BIOS, o) 60150BIOS, p) 60175, q) 60200BIOS, r) 60225BIOS, s) 60250BIOS, t) 60275, u) 60300, v) 60350, w) 60400BIOS, x) 60450BIOS

    The Surgical Tools and Cardiovascular Specialty marketing brochures distributed for Flo-Rester Disposable Internal Vessel Occluder, Flo-Thru Intraluminal Shunt, and Vascular Probe Intravascular Probe contain inaccurate content that does not align with the products Instructions for Use (IFU).

  • 2024-04-12Open, ClassifiedUnder Investigation by firm

    Surgical Tools and Cardiovascular Specialty marketing brochures, Reference numbers: US-AS18-210002 Surgical Tools Brochure 2021, US-AS18-210004 Surgical Tools Website v1, and US-AS46-230002 CV Specialty Brochure US version which affect: Flo-Thru Intraluminal Shunt, Item Numbers: a) FT12100, b) FT12125, c) FT12150, d) FT12175, e) FT12200, f) FT12225, g) FT12250, h) FT12275, i) FT12300,

    The Surgical Tools and Cardiovascular Specialty marketing brochures distributed for Flo-Rester Disposable Internal Vessel Occluder, Flo-Thru Intraluminal Shunt, and Vascular Probe Intravascular Probe contain inaccurate content that does not align with the products Instructions for Use (IFU).

  • 2024-04-12Open, ClassifiedUnder Investigation by firm

    Surgical Tools and Cardiovascular Specialty marketing brochures, Reference numbers: US-AS18-210002 Surgical Tools Brochure 2021, US-AS18-210004 Surgical Tools Website v1, and US-AS46-230002 CV Specialty Brochure US version which affect: Vascular Probe, Item Numbers: a) 7081015, b) 7081015ES, c) 7081520, d) 7081520ES, e) 7082025, f) 7082025ES, g) 7151015, h) 7151015ES, i) 7151520, j) 7151520ES, k) 7152025, l) 7152025ES, m) 7451015, n) 7451015ES, o) 7451520, p) 7451520ES, q) 7452025, r) 7452025ES

    The Surgical Tools and Cardiovascular Specialty marketing brochures distributed for Flo-Rester Disposable Internal Vessel Occluder, Flo-Thru Intraluminal Shunt, and Vascular Probe Intravascular Probe contain inaccurate content that does not align with the products Instructions for Use (IFU).

  • 2024-01-05Open, ClassifiedUnder Investigation by firm

    Baxter Flo-Rester, Disposable internal vessel occluder, distributed in the following sizes: a) Product Code 50100: 12MM, 1.00 MM GLOBAL; b) Product Code 50150: 12MM, 1.50 MM GLOBAL; c) Product Code 50175: 12MM, 1.75 MM GLOBAL; d) Product Code 50200: 12MM, 2.00 MM GLOBAL; e) Product Code 50225: 12MM, 2.25 MM GLOBAL; f) Product Code 50250: 12MM, 2.50 MM GLOBAL; g) Product Code 50275: 12MM, 2.75 MM GLOBAL; h) Product Code 50300: 12MM, 3.00 MM GLOBAL; i) Product Code 50350: 12MM, 3.50 MM GLOBAL; j) Product Code 50400: 12MM, 4.00 MM GLOBAL; k) Product Code 60100: 30MM, 1.00 MM GLOBAL; l) Product Code 60175: 30MM, 1.75 MM GLOBAL; m) Product Code 60275: 30MM, 2.75 MM GLOBAL; n) Product Code 60300: 30MM, 3.00 MM GLOBAL; o) Product Code 60350: 30MM, 3.50 MM GLOBAL; p) Product Code 50125: 12MM, 1.25 MM GLOBAL; q) Product Code 50450BIOS: 12MM, 4.50 MM GLOBAL; r) Product Code 60125BIOS: 30MM, 1.25 MM GLOBAL; s) Product Code 60150BIOS: 30MM, 1.50 MM GLOBAL; t) Product Code 60200BIOS: 30MM, 2.00 MM GLOBAL; u) Product Code 60225BIOS: 30MM, 2.25 MM GLOBAL; v) Product Code 60250BIOS: 30MM, 2.50 MM GLOBAL; w) Product Code 60400BIOS: 30MM, 4.00 MM GLOBAL; x) Product Code 60450BIOS: 30MM, 4.50 MM GLOBAL

    Cardiovascular Surgery marketing brochure (US-AS46-220001) that was distributed for the products listed below contains inaccurate content that does not align with some of the products Instructions for Use (IFU) or Prescribing Information (PI).

  • 2024-01-05Open, ClassifiedUnder Investigation by firm

    Baxter Flo-Thru Intraluminal Shunt, Product Codes: a) Product Code FT12100, 1.00 GLOBAL; b) Product Code FT12125, 1.25 GLOBAL; c) Product Code FT12150, 1.50 GLOBAL; d) Product Code FT12175, 1.75 GLOBAL; e) Product Code FT12200, 2.00 GLOBAL; f) Product Code FT12225, 2.25 GLOBAL; g) Product Code FT12250, 2.50 GLOBAL; h) Product Code FT12275, 2.75 GLOBAL; i) Product Code FT12300, 3.00 GLOBAL

    Cardiovascular Surgery marketing brochure (US-AS46-220001) that was distributed for the products listed below contains inaccurate content that does not align with some of the products Instructions for Use (IFU) or Prescribing Information (PI).

  • 2022-04-29TerminatedProcess control

    Flo-Thru Intraluminal Shunt. Used in coronary artery or peripheral vascular procedures. Used to shunt blood at the anastomosis to provide a temporary blood-free operative field for suturing while allowing blood to flow distal to the anastomosis.

    There is a potential for foreign matter.

Monitor clamp, vascular automatically