Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass
FDA adverse event reports and recall history for adaptor, stopcock, manifold, fitting, cardiopulmonary bypass (product code DTL), from the public MAUDE/AEMS corpus and the live FDA recall database.
- Total reports
- 2,128
- Deaths
- 18
- Injuries
- 144
- Malfunctions
- 1,931
Reports per year
Source: FDA adverse event reports by year received, 2012–2026. Reporting paused during the 2026 MAUDE-to-AEMS transition and has since resumed.
Recent recalls
- 2026-05-08Open, ClassifiedUnder Investigation by firm
Namic Angiographic Manifold, custom, Medline Product Number/SKU 64038200; Cardiopulmonary bypass adaptor, stopcock, manifold, or fitting.
Medline has identified the presence of particulate within the fluid path of the Manifolds.
- 2026-05-08Open, ClassifiedUnder Investigation by firm
Namic Angiographic Manifold, custom, Medline Product Number/SKU 64038301; Cardiopulmonary bypass adaptor, stopcock, manifold, or fitting.
Medline has identified the presence of particulate within the fluid path of the Manifolds.
- 2026-05-08Open, ClassifiedUnder Investigation by firm
Namic Angiographic Manifold, custom, Medline Product Number/SKU 64038402; Cardiopulmonary bypass adaptor, stopcock, manifold, or fitting.
Medline has identified the presence of particulate within the fluid path of the Manifolds.
- 2026-04-07Open, ClassifiedUnder Investigation by firm
Medline medical convenience kits, containing NAMIC Angiographic Rotating Adaptor (RA) Control Syringes (Namic RA syringes), labeled as follows: 1. CSTM MANIFOLD KIT - TITUS, Medline SKU VASC1061; 2. CSTM MANIFOLD KIT - FRYE, Medline SKU VASC1074; 3. CRYO EP MANIFOLD KIT, Medline SKU VASC1198; 4. MANIFOLD KIT - 500PSI OFF, Medline SKU VASCSHPOFF1; 5. MANIFOLD KIT LOW PRESSURE ON, Medline SKU VASCSLPON1.
Medline Industries, LP has identified through post-market surveillance a potential risk of the syringe rotating adaptor unwinding during use, which may result in a loose connection and/or full disconnection between the syringe and manifold.
- 2025-11-17Open, ClassifiedProcess change control
PhD Hemostasis Valve, REF: IN4802/K, IN4802/T, IN4918/A, IN7802/C, IN8802/C, IN9802, IN9802/A, K05-02166B, K05T-02138A, K12T-10798A, MAP800/B, MAP800/T, MAP801/B, MAP802/B, MAP802/CNB, MAP802/T, MAP804/B, MAP852/B, SKY1802.
Hemostasis valve has a manufacturing defect and when used the valve cap may remain depressed, leading to potential leakage, which may result in procedure inconvenience and/or hemorrhage.
- 2025-09-11Open, ClassifiedEmployee error
10Fore Hemostasis Valve Catalog Number / UDI-DI code: MAPTEN4 / 00884450821305 MAPTEN42 / 00884450832509 MAPTEN452 / 00884450821329 The 10Fore Hemostasis Valve is intended to maintain hemostasis during the introduction/withdrawal and use of diagnostic and interventional devices.
Due to a manufacturing issue involving the silicone quad ring where the ring is deformed or otherwise damaged and may cause a foreign body in the fluid pathway.
- 2024-09-06Open, ClassifiedUnder Investigation by firm
Medline Convenience kits labeled as: 1) KIT MANIFOLD CSTM-NORTHRIDGE, Pack Number 129736 ; 2) KIT LEFT HEART-VA MED, Pack Number 132701; 3) KIT MANIFOLD CSTM-RENAISSANC, Pack Number 134085 ; 4) KIT LEFT HEART- LEXINGTON , Pack Number 142643 ; 5) KIT ANGIO CSTM-SETON, Pack Number 143267; 6) SYR- VA HOSPITAL, Pack Number 144684; 7) BYPASS ENCOMPASS CDS, Pack Number CDS985003A; 8) CSTM MANIFOLD KIT , Pack Number SAMPC0547; 9) CSTM MANIFOLD KIT - FRYE, Pack Number VASC1074 ; 10) CSTM MANIFOLD KIT , Pack Number VASC1130
Medical convenience kits contain plastic syringes affected by the FDA Safety Alert issued on March 19, 2024. Leaks, breakage, and/ other quality issues have been identified that may pose a risk to patient health.
- 2023-05-16Open, ClassifiedProcess control
WATCHDOG Hemostasis Valve Kit, UPN H74939343A022 (outer package), UPN H74939343A020 (inner package)
The firm received complaints of the Insertion Tool component being occluded, resulting in the inability to pass a guidewire through the tool.
- 2023-05-16Open, ClassifiedProcess control
WATCHDOG ACCESSORY KIT (20-PACK), UPN H74939343A021 (outer package), UPN H74939343A020 (inner package)
The firm received complaints of the Insertion Tool component being occluded, resulting in the inability to pass a guidewire through the tool.
- 2018-05-09TerminatedEquipment maintenance
Connecting Tube - Female to Male Luer Lock, HPCT8.8-60-M-FM Product Usage: The connecting tube is intended to be a conduit between a fluid reservoir and a vascular catheter in the patient. The connecting tube may be used during angiographic procedures to connect radiographic contrast power injector to a vascular catheter, arterial pressure monitoring, and fluid infusion.
Cap-adapter assembly of the device may potentially not be adequately tightened, possibly leading to fluid leakage from or air aspiration into the connecting tube.
Monitor adaptor, stopcock, manifold, fitting, cardiopulmonary bypass automatically
DeviceWatch watches FDA adverse events and recalls for the products you care about, summarizes clinical narratives with AI and alerts you when a safety signal emerges.