Skip to main content
DRCClass 2

Trocar

FDA adverse event reports and recall history for trocar (product code DRC), from the public MAUDE corpus and the live FDA recall database.

Total reports
2,004
Deaths
59
Injuries
941
Malfunctions
956

Reports per year

12
13
14
15
16
17
18
19
20
21
22
23
24
25
26

Source: FDA adverse event reports by year received, 2012–2026. Reporting paused twice in 2026 during FDA reporting-system changes and has since resumed.

Recent recalls

  • 2024-04-12Open, ClassifiedUnder Investigation by firm

    Trocar Needle - Used for dilating puncture sites or catheter tracts for percutaneous placement of devices for vascular and non-vascular applications such as in the venous, arterial, biliary and renal system REFERENCE PART NUMBER (RPN): DTN-18-20.0 ORDER NUMBER (GPN): G01377

    Packaging may have low seal strength and not meet peel strength specifications, compromising device sterility

  • 2019-03-13TerminatedProcess control

    Cook Transseptal Needle, Reference Number TSNC-18-71.0, Order Number G02364. For transseptal left heart access in both diagnostic and interventional procedures.

    The products were manufactured without a back bevel on the needle tip. This could cause damage to the inside of the introducer during needle insertion.

  • 2014-12-16TerminatedNo Marketing Application

    A trocar is a sharp-pointed instrument used with a cannula for piercing a vessel or chamber to facilitate insertion of the cannula sold under the Symmetry Surgical, CareFusion, and Ambler Surgical brand names.

    The reason these devices are being withdrawn from the market by Instrumed is that Instrumed did not market these devices prior to September 26, 1976, and therefore, does not meet all FDA requirements to market the devices as "Pre-Amendment" devices.

  • 2014-10-29TerminatedError in labeling

    Blunt Hurd Cannula Blunt Tip 10 mm with 5 mm Reducer simplifies open laparoscopy.

    CooperSurgical is recalling two lots of 900-863 because the wrong package insert (IFU) was placed into the shipper.

  • 2010-07-13TerminatedOther

    Angiotech Vascular Access Needle. A) "Modified Potts/Cournand" Needle. STERILE. Product Number: MPCN1802. 510k K974745. Qty Dist. - 425. B) "Seldinger" Needle. STERILE. Product Number: SN1802, SN1902. 510k K974745. Qty Dist. - 5,250. MEDICAL DEVICE TECHNOLOGIES, INC. 3600 Southwest 74th Avenue, Gainesville, Florida 32608 U.S.A. Intended use: Vascular Access Needle

    Medical Device Technologies doing business as Angiotech has conducted a recall on Angiotech Breast Localization Needles, Soft Tissue Biopsy Needles, Vascular Access Needles, Bone Biopsy Needles, Access Needles, Galactography Kit, Stabilization Needles and Needle Guides for packaging integrity.

  • TerminatedNonconforming Material/Component

    Transseptal Needle, Trocar. RPN TSNC-18-71.0, TSNC-19-56.0. GPN G02364, G02365. Product consists of a transseptal needle and obturator.

    Transseptal needles may contain rust on the interior and/or exterior of the needle, which may not be detected by the user. Potential adverse events if an affected product is used ranges from increased procedural time to inflammatory reactions, which at their most severe include systemic reactions potentially leading to permanent impairment or death.

  • TerminatedDevice Design

    ENDOPATH XCEL" with OPTIVIEW" Technology trocar Product Codes: Product Code #: 03B11LP-Lot #'s: G4RW5U, G4RZ7L, G4T33Y & G4T58C. Product Code #: 03B11LPH- Lot #'s: G4RX8G, G4RZ3X & G4T03X. Product Code #: 03B11LT- Lot #'s: G4RH57, G4RH49, G4RJ9H, G4RK2U, G4RK90, G4RL5P, G4RM16, G4RM1F, G4RM7E,G4RN1E, G4RP3L, G4RT0T, G4RT9D, G4RV4M, G4RV4D, G4RW9Z, G4RX5R, G4RY23, G4RY7P, G4RZ6G, G4T093, G4T167, G4T22M, G4T27A, G4T27W, G4TC7V, G4TD1U, G4TE1P, G4TF0N, G4TF3J, G4TH07, G4TG6D, G4TH5L, G4TJ44, G4TK1J, G4TK6E, G4TL3A, G4TL95, G4TM49, G4TM88, G4TN2H, G4TN88, G4TP1R, G4TP4X, G4TP89,G4TR4X, G4TT3K, G4TT97, G4TU8J, G4TV4W, G4TW1C, G4TX0C & G4TX8Z. Product Code #: 03B11LTH-Lot #'s: G4RW20, G4T03Y, G4T26Y, G4T49F, G4T73A, G4TX0R & G4TX9D. Product Code # 03B12LP-Lot #'s: G4RV5F, G4RY26, G4T27X, G4T55H & G4T75Y. Product Code #: 03B12LPH-Lot #'s: G4RW5T, G4RZ3Y, G4T03Z, G4T32C & G4T49G. Product Code #: 03B12LT-Lot #'s: F4PX6F, F4PZ4D, F4PZ22, F4PY9K, F4PY9E, F4PZ6F, F4PZ9Z, F4R01X, F4R039, F4R00M, F4R09W, F4R10Z, F4R15N, F4R18K, F4R18E, F4R234, F4R255, F4R278, F4R256, F4R35D, F4R34N, F4R34L, F4R369, F4R393, F4R40J, F4R44A, F4R458, G4R601, G4R71Y, G4R71Z, G4R80H, G4R77Z, G4R77Y, G4R860, G4R87V, G4R920, G4R915, G4R962, G4R97Z, G4R84L, G4RA7D, G4RA8N, G4RC45, G4RC79, G4RC8D, G4RC98, G4RD2A, G4RC8E, G4RD24, G4RD4V, G4RE84, G4RG18, G4RG3T, G4RG83, G4RF0A, G4RH0C, G4RG31, G4RG32, G4RF8C, G4RJ08, G4RJ92, G4RJ9E, G4RK6L, G4RL02, G4RL1L, G4RL2E,G4RL8P, G4RL8Y, G4RM31, G4RM49, G4RN06, G4RN27, G4RN30, G4RN2K, G4RN5D, G4RN8F, G4RN7Z, G4RP1K, G4RR2N, G4RR3K, G4RT28, G4RT09, G4RT3G, G4RT3J,G4RU8H, G4RV1F, G4RV1G, G4RV89, G4RV8J, G4RW55, G4RW54, G4RX59, G4RZ15, G4RY7W, G4RY8V, G4RY8W, G4RZ29, G4RZ6W, G4RZ6V, G4RZ6H, G4RZ6U, G4T01U, G4T04J, G4T04H, G4T14X, G4T23R, G4T296, G4T34K, G4T36A, G4T34P, G4T41E, G4T44W, G4T46C, G4T45N, G4T50W, G4T529, G4T63Z, G4T66H, G4T64N, G4T66J, G4T750, G4T70Y, G4T711, G4T73J, G4T78T, G4T81R, G4T78U, G4T83Y, G4T93A, G4T87T, G4T95J, G4T90T, G4T89V, G4T94W, G4T941, G4T940, G4T976, G4TA1E, G4TA5W, G4TA7D, G4TA5X, G4TA9H,G4TA96, G4TC3Y, G4TC4Y, G4TC4X, G4TC80, G4TD3W, G4TD3G, G4TF02, G4TD8Z, G4TD9Z, G4TF8Z, G4TG0W, G4TG31, G4TG4H, G4TG6X, G4TH16, G4TH5M, G4TH79, G4TJ2A, G4TJ6U, G4TJ5W, G4TJ8Y, G4TJ9W, G4TK2F, G4TK86, G4TK9H, G4TL5Z, G4TL7R, G4TL9N, G4TM5T, G4TM3H, G4TM87, G4TP14, G4TR1F, G4TP7K, G4TR54, G4TR3A, G4TR7H, G4TR9M, G4TT0G, G4TT20, G4TT43, G4TT7R, G4TU1D, G4TU3J, G4TV22, G4TU89, G4TW0N, G4TV5V, G4TW3V, G4TW5U, G4TX16, G4TX2D, G4TX8R, G4TX7E & G4TY19. Product Code #: 03B12LTH- Lot #'s: G4RW31, G4RW2R, G4RZ48, G4T00F, G4T27C, G4T448, G4T56N, G4T549, G4T59L, G4T65G, G4T709, G4TE35, G4TF2E, G4TG03, G4TG73, G4TH21, G4TM00, G4TT3F, G4TU3P &G4TX0T. Product Code #: 03B12SRT- Lot #'s: G4RW52, G4RZ25, G4T05J, G4T465 & G4T76T. Product Code #: 04B12XT-Lot #'s: G4RU2U, G4RW8N, G4RV59, G4RW97, G4T19T, G4T79U, G4TA2A, G4TA7K, G4TD2C, G4TF0R, G4TJ1L, G4TM3X, G4TN8E, G4TR00, G4TT2W, G4TW4E, G4TW55 & G4TY7G. Product Code #'s: 03CB11LT-Lot #'s: G4RH8R, G4RK9Z, G4RL5R, G4RM8H, G4RN6Z, G4RT08, G4RV2F, G4RY0X, G4RZ5N, G4T12D, G4T20J, G4T31F, G4T444, G4T50E, G4TL5Y, G4TL8F, G4TU70 & G4TX6J. Product Code #: 03CB12LT-Lot Code #'s: F4R421, G4R93M, G4R989, G4RA4E, G4RA7Z, G4RA8M, G4RC4N, G4RD94, G4RG1F, G4RG4X, G4RG91, G4RH7X, G4RJ9A, G4RN3R, G4RR4T, G4RT8H, G4RU3C, G4RU6V, G4RV2U, G4RW9J, G4RY1R, G4RY6L, G4RZ68, G4T092, G4T14D, G4T229, G4T243, G4T26W, G4T31T, G4T32W, G4T37M, G4T37N, G4T410, G4T449, G4T45Z, G4T47R, G4T48G, G4T551, G4T71V, G4T74Z, G4T81K, G4T83U, G4T894, G4T92T, G4T98R, G4TA4Z, G4TA9X, G4TC2L, G4TC6L, G4TD1E, G4TD68, G4TE07, G4TE9W, G4TF2M, G4TG16, G4TG61, G4TG8P, G4TH58, G4TJ2G, G4TJ99, G4TK3H, G4TK1H, G4TL76, G4TM3D, G4TM5W, G4TN2E, G4TN81, G4TP0V, G4TP9D, G4TR4W, G4TR77, G4TU0L, G4TU86, G4TV4F, G4TV9F, G4TW9U & G4TX7P. Product Code #: 02D11LT- Lot Code #'s: G4RR2U, G4RR34, G4RT5N, G4RT47, G4RT53, G4RU05, G4RX11, G4RX7V, G4RZ28, G4RZ4M, G4T06C, G4T09H, G4T171, G4T18U, G4T28K, G4T38Y, G4T46L, G4T51N, G4T55T, G4T590, G4

    This recall has been initiated because Ethicon Endo-Surgery is aware of an increase in reports of leaking in the ENDOPATH XCEL" with OPTIVIEW" Technology trocar, which potentially can lead to loss of pneumoperitoneum during a surgical procedure. Pneumoperitoneum leaks may lead to conversion from laparoscopic to open surgery.

  • TerminatedProcess control

    HeartSpan Transseptal Needles Catalog No. FND-019-01, Lot No. E1913644 consisting of an outer needle cannula and an inner stylet. The needle is comprised of flexible thin walled tubing with an ergonomic hub and stopcock attached to the proximal end. The stylet consists of a solid wire that when inserted in the needle protrudes beyond the distal tip of the cannula.

    The labeled needle tip curvature of specific lots of transseptal needles may not match the actual needle tip curvature. In the event that the incorrect needle is unknowingly used, an unintended anatomy puncture may occur, which is likely to require medical intervention.

  • TerminatedProcess control

    Heartspan Transseptal Needles, Catalog No. FND-019-02, Lot No. E1913645 consisting of an outer needle cannula and an inner stylet. The needle is comprised of flexible thin walled tubing with an ergonomic hub and stopcock attached to the proximal end. The stylet consists of a solid wire that when inserted in the needle protrudes beyond the distal tip of the cannula.

    The labeled needle tip curvature of specific lots of transseptal needles may not match the actual needle tip curvature. In the event that the incorrect needle is unknowingly used, an unintended anatomy puncture may occur, which is likely to require medical intervention.

  • TerminatedSoftware design

    Boston Scientific TSX Transseptal Needle, Model Number M004TSX60o; Used to create the primary puncture in the interatrial septum when passing an intruder and/or catheter through the septum from the right side of the heart to the left side.

    Merit Medical Systems, Inc. is voluntarily conducting a recall of one lot of the TSX" Transseptal Needle due to a discrepancy between the labeling and the actual configuration of the device in the packaging. The curve dimensional values on the labels of this lot incorrectly indicate a 50 curve, rather than the correct 86 curve

Monitor trocar automatically