Skip to main content
CEWClass 2

Radioimmunoassay, Parathyroid Hormone

FDA adverse event reports and recall history for radioimmunoassay, parathyroid hormone (product code CEW), from the public MAUDE corpus and the live FDA recall database.

Total reports
1,485
Deaths
0
Injuries
20
Malfunctions
1,446

Reports per year

12
13
14
15
16
17
18
19
20
21
22
23
24
25
26

Source: FDA adverse event reports by year received, 2012–2026. Reporting paused twice in 2026 during FDA reporting-system changes and has since resumed.

Recent recalls

  • 2025-10-27Open, ClassifiedUnder Investigation by firm

    Assay: IMMULITE 2000 Intact PTH; Test Code: iPT; Siemens Material Number (SMN): (1) 10381441, (2) 10381442; Catalog Number: (1) L2KPP2, (2) L2KPP6;

    The potential for falsely depressed Intact PTH patient results at the low end of the assay range, less than or equal to 50 pg/mL (less than or equal to 5.3 pmol/L), when using specific lots identified by the firm on the IMMULITE 2000/IMMULITE 2000 XPi systems. The bias is observed in both serum and plasma samples.

  • 2025-01-03Open, ClassifiedNonconforming Material/Component

    Access Intact PTH assay, a paramagnetic particle, chemiluminescent immunoassay for the quantitative determination of intact parathyroid hormone (parathyrin, PTH) levels in human serum and plasma using the Access Immunoassay Systems, Catalog Number A16972

    Beckman Coulter has identified that some Access PTH reagent packs from lot 339071 may be over- or under-filled in well 0. The dispensed material in well 0 could be above or below specification, risking sealing issues, contamination, instrument errors, delays, or inaccurate results with a negative bias and increase in imprecision. The issue was confirmed on 10 April 2024 by Beckman Coulter through an internal non-conformance (NC-INT-66585). The well 0 scale on the filling line began malfunctioning on the fill immediately before PTH. The malfunction was not noticed until the majority of PTH was filled.

  • 2024-12-11Open, ClassifiedProcess design

    Access Intact PTH assay on the DxI 9000 Access Immunoassay Analyzer, Catalog number A16972, for the quantitative determination of intact parathyroid hormone (parathyrin, PTH) levels in human serum and plasma.

    The reason for the recall is that EDTA and lithium heparin plasma samples that are stored in the DxI 9000 Access Immunoassay Analyzer sample wheel for a prolonged period before performing the intact PTH (parathyroid hormone) test may produce falsely decreased intact parathyroid hormone results. This could lead to a missed diagnosis, a delay in treatment, or inappropriate clinical management, depending upon the patient s clinical condition.

  • 2023-01-25Open, ClassifiedUnder Investigation by firm

    Future Diagnostics STAT-IntraOperative-Intact-PTH (STAT-IO-I-PTH) Immunoassay kit REF 4K-IPT-00. in vitro diagnostic.

    Due to an issue of high coefficient of variability (CV) problem caused by the accuspheres inside the Immunoassay kits.

  • 2023-01-04Open, ClassifiedUnder Investigation by firm

    VITROS Immunodiagnostic Products Intact PTH Reagent Pack- IVD For the quantitative measurement of intact parathyroid hormone (iPTH) in human serum and plasma (EDTA or heparin) Catalog Number: 6802892

    Lower than expected iPTH patient and Quality Control (QC) results, reported negatively biased iPTH results- an average -12% shift in patient sample results

  • 2013-11-06TerminatedPackaging

    ADVIA Centaur Intact PTH Calibrator (6 pack); Catalog Number: SMN 10492387 For in vitro diagnostic use in calibrating Intact PTH assays on the ADVIA Centaur Systems.

    PTH Calibrator packaged with only high calibrator.

  • 2013-06-06TerminatedNo Marketing Application

    ADVIA Centaur iPTH ReadyPack Assay 100 Tests; REF 10492368. For in vitro diagnostic use in the quantitative determination of intact parathyroid hormone (iPTH).

    iPTH Assay- reagent and calibrator lots may have demonstrated higher than anticipated variability

  • 2013-06-06TerminatedNo Marketing Application

    ADVIA Centaur iPTH ReadyPack Assay 500 Tests; REF 10492369, 10493615, 1049361. For in vitro diagnostic use in the quantitative determination of intact parathyroid hormone (iPTH).

    iPTH Assay- reagent and calibrator lots may have demonstrated higher than anticipated variability

  • 2012-03-07TerminatedProcess control

    ADVIA Centaur Intact PTH (iPTH) Assay -assay (lot 138) Cat. Nos. 100 Test kit 04385983 (129501) 500 Test kit 06587575 (129502). For in vitro diagnostic use in the quantitative determination of intact parathyroid hormone (PTH) in EDTA plasma or serum using the ADVIA Centaur systems. This assay is intended to be used to aid in the differential diagnosis of hyperparathyroidism, hypoparathyroidism, or hypercalcemia of malignancy.

    Poor sensitivity and imprecision on ADVIA Centaur systems; Serum samples low bias; EDTA plasma samples low bias

  • 2010-12-09TerminatedPending

    Active I-PTH ELISA, Part Number: DSL-10-8000 The DSL-10-80000 ACTIVE I-PTH Enzyme-Linked Immunosorbent Assay (ELISA) Kit provides materials for the quantitative measurement of I-PTH in serum or plasma. This assay is intended for in vitro diagnostic use as an aid in the diagnosis of hyperparathyroidism.

    The recall was initiated because Beckman Coulter has confirmed that the stated stability of the DSL-10-8000 I-PTH ELISA and DSL-8000 I-PTH IRMA assays may not be achieved for the lot numbers affected by the recall. The affected I-PTH ELISA and the I-PTH IRMA kit lots may produce falsely elevated patient results. Internal stability testing showed an average 16% elevation for I-PTH ELISA lot 99

Monitor radioimmunoassay, parathyroid hormone automatically

DeviceWatch watches FDA adverse events and recalls for the products you care about, summarizes clinical narratives with AI and alerts you when a safety signal emerges.