BYEClass 2

Attachment, Breathing, Positive End Expiratory Pressure

FDA adverse event reports and recall history for attachment, breathing, positive end expiratory pressure (product code BYE), from the public MAUDE corpus and the live FDA recall database.

Total reports
255
Deaths
34
Injuries
77
Malfunctions
125

Reports per year

11
12
13
14
15
17
18
19
20
21
22
23
24
25
26

Source: FDA adverse event reports by year received, 2011–2026. Reporting paused twice in 2026 during FDA reporting-system changes and has since resumed.

Recent recalls

  • 2026-10-01Open, ClassifiedUnder Investigation by firm

    VentStar Resus Neo. Neonatal. 25 Units per Box. Part Number: MP00310 Disposable breathing circuit for use with a resuscitation module.

    Potential cracks in the hose, which could lead to leakage or the hose falling off.

  • 2015-12-24TerminatedNonconforming Material/Component

    Airways Development LLC WaterPAP Positive Airway Pressure Device Reference #WP-7700.

    Airways Development LLC has received a complaint about a canister leaking from WaterPAP Lot 8605A. During a review with their supplier it could not be determined if this was an isolated incident or if the whole lot is impacted.

  • 2008-07-16TerminatedNonconforming Material/Component

    Smiths Medical FLO2 Emergency Non-rebreather High Flow O2 System; Positive end expiratory pressure breathing attachment; Reference Number: P60000; Smiths Medical, Rockland, MA 02370.

    Incorrect Oxygen Level: Device may not provide expected oxygen concentration or the expected flow rate due to incorrectly molded part. Patient will not receive proper amounts of air/oxygen when in need.

  • 2008-07-16TerminatedNonconforming Material/Component

    Smiths Medical Oxy-PEEP High Flow O2 with PEEP; Positive end expiratory pressure breathing attachment; Reference Number: P63000; Smiths Medical, Rockland, MA 02370.

    Incorrect Oxygen Level: Device may not provide expected oxygen concentration or the expected flow rate due to incorrectly molded part. Patient will not receive proper amounts of air/oxygen when in need.

  • 2007-12-22TerminatedProcess design

    Ambu, Positive End Expiratory Pressure (PEEP) Valves, PEEP Valve 10, 30 mm, REF 000 137 000, Manufacturer: Ambu International A/S, DK2750 Ballerup USA: Ambu Inc. (Ambu USA) Linthicum, MD 21090-1356 USA, Made in Denmark

    Lower pressure than expected: Medical device for respiratory care may leak and not register accurate flow settings that affect patient respiration.

  • 2007-12-22TerminatedProcess design

    Ambu, Positive End Expiratory Pressure (PEEP) Valves, PEEP Valve 10, 22/18 mm, REF 000 138 000, Manufacturer: Ambu International A/S, DK2750 Ballerup USA: Ambu Inc. (Ambu USA) Linthicum, MD 21090-1356 USA, Made in Denmark

    Lower pressure than expected: Medical device for respiratory care may leak and not register accurate flow settings that affect patient respiration.

  • 2007-12-22TerminatedProcess design

    Ambu, Positive End Expiratory Pressure (PEEP) Valves, PEEP Valve 10, 22/18 mm, 30mm connector, REF 137 001 000, Manufacturer: Ambu International A/S, DK2750 Ballerup USA: Ambu Inc. (Ambu USA) Linthicum, MD 21090-1356 USA, Made in Denmark

    Lower pressure than expected: Medical device for respiratory care may leak and not register accurate flow settings that affect patient respiration.

  • 2007-12-22TerminatedProcess design

    Ambu, Positive End Expiratory Pressure (PEEP) Valves, PEEP Valve Spare Part, REF 137 000 501, Manufacturer: Ambu International A/S, DK2750 Ballerup USA: Ambu Inc. (Ambu USA) Linthicum, MD 21090-1356 USA, Made in Denmark

    Lower pressure than expected: Medical device for respiratory care may leak and not register accurate flow settings that affect patient respiration.

  • TerminatedDevice Design

    Neo-Vent Infant T-Piece Resuscitation Circuit;Circuit for use on compatible Infant Resuscitators. 15mm OD x 10mm ID connector; REF 0415, Qty:10, Length: 60" (1.5cm), Rx Only.

    A repair was made to an adapter mold resulting in parts being produced with compliant 10mm ID connections and non-compliant 15mm OD connections. This resulted in facilities with infant resuscitators that connect via the 15mm OD fitting not being able to use those circuits.

  • TerminatedDevice Design

    Neo-Vent Infant T-Piece Resuscitation Circuit With Infant Mask; Circuit for use on compatible Infant Resuscitators. 15mm OD x 10mm ID connector; REF 0420, Qty:10, Length: 60" (1.5cm), Rx Only.

    A repair was made to an adapter mold resulting in parts being produced with compliant 10mm ID connections and non-compliant 15mm OD connections. This resulted in facilities with infant resuscitators that connect via the 15mm OD fitting not being able to use those circuits.

Monitor attachment, breathing, positive end expiratory pressure automatically